| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GB-KF30010Y |
| Instrument Type | Aerosol Filtration Efficiency Tester |
| Filtration Efficiency Range | 0–99.999% |
| Aerosol Flow Rate | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Concentration Range | 0.001–100 mg/m³ (±1% accuracy) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Control | Temperature 25 °C ± 5 °C, Relative Humidity 30 %RH ± 10 %RH |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XF-10010 |
| Instrument Type | Aerosol Detector |
| A-Path Sampling Flow | 28.3 L/min ±2.5% (0.1 L/min resolution) |
| B-Path Sampling Flow | 28.3 L/min ±2.5% (0.1 L/min resolution) |
| Nebulizer Flow | (8–10) L/min ±2.5% (0.1 L/min resolution) |
| Peristaltic Pump Flow | (0.006–3.0) mL/min ±2.5% (0.001 mL/min resolution) |
| Pressure Before A/B Flowmeters | (−20–0) kPa ±2.5% (0.01 kPa resolution) |
| Pressure Before Nebulizer | (0–300) kPa ±2.5% (0.1 kPa resolution) |
| Ambient Temperature Range | (−40–99) °C ±2.5% (0.1 °C resolution) |
| Aerosol Chamber Negative Pressure | (−90–−120) Pa ±2.0% (0.1 Pa resolution) |
| Cabinet Negative Pressure | −50 to −200 Pa |
| Data Storage Capacity | >100,000 test records |
| Vortex Mixer | 8 × Φ16×150 mm tubes |
| HEPA Filter Efficiency | ≥99.99% for particles ≥0.3 µm |
| Aerosol Generator MMAD | 3.0 ± 0.3 µm, GSD ≤1.5 |
| Andersen Six-Stage Impactor Cut Points | Stage I >7 µm, II: 4.7–7 µm, III: 3.3–4.7 µm, IV: 2.1–3.3 µm, V: 1.1–2.1 µm, VI: 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 60 cm (L) × 8.5 cm (Ø) × 3 cm (T) |
| Positive Control Target | 2200 ± 500 CFU |
| Cabinet Ventilation Flow Rate | ≥5 m³/min |
| Cabinet Door Size | W1000 × D730 mm |
| Main Unit Dimensions | W1180 × D650 × H1300 mm |
| Adjustable Stand Dimensions | W1180 × D650 × H600 mm (±10 cm height adjustment) |
| Noise Level | <65 dB(A) |
| Weight | ~150 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Brand | GBPI |
|---|---|
| Model | GB-XF1000T |
| Instrument Type | Aerosol Detector |
| Origin | Guangdong, China |
| Manufacturer | Guangzhou GBPI Packaging Testing Instruments Co., Ltd. |
| Compliance | YY 0469–2004, YY/T 0969–2013, ASTM F2100, ASTM F2101, EN 14683 |
| Sampling Method | Dual-channel parallel Andersen cascade impactor (6-stage) with simultaneous control of A/B flow paths |
| Aerosol Generation | Microbial aerosol generator with mass median aerodynamic diameter (MMAD) = 3.0 ± 0.3 µm, GSD ≤ 1.5 |
| Flow Rate (A/B) | 28.3 L/min ±2.5% (resolution: 0.1 L/min) |
| Nebulizer Flow | 8–10 L/min ±2.5% (resolution: 0.1 L/min) |
| Peristaltic Pump Flow | 0.006–3.0 mL/min ±2.5% (resolution: 0.001 mL/min) |
| Pressure Monitoring | Upstream pressure (–20 to 0 kPa),雾室 negative pressure (–90 to –120 Pa), cabinet negative pressure (–50 to –200 Pa), all ±2.0–2.5% accuracy |
| Temperature Range | –40 to 99 °C (±2.5%) |
| Aerosol Chamber | 600 mm × 85 mm Ø × 30 mm |
| Positive Control | 2200 ± 500 CFU total viable count |
| Cabinet Airflow | ≥5 m³/min |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Net Weight | ~150 kg |
| Dimensions (main unit) | 1180 × 650 × 1300 mm (W×D×H) |
| Adjustable Stand Height | ±100 mm |
| Data Storage Capacity | >100,000 test records |
| Display | 10.4″ industrial-grade high-brightness TFT touchscreen |
| Interface | USB port for data export via U-disk |
| Safety Features | Interlocked negative-pressure cabinet, built-in leakage protection, flame-retardant insulation, front-access tempered glass door, LED internal lighting |
| Filter Efficiency | ≥99.99% for particles ≥0.3 µm (HEPA) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XF-10010Q |
| Instrument Category | Aerosol Detector |
| Sampling Flow Rate (A/B) | 28.3 L/min ±2.5% |
| Nebulizer Flow Rate | (8–10) L/min ±2.5% |
| Peristaltic Pump Flow Range | (0.006–3.0) mL/min ±2.5% |
| Pressure Measurement Accuracy | ±2.5% (except aerosol chamber: ±2.0%) |
| Aerosol MMAD | 3.0 ± 0.3 µm, GSD ≤1.5 |
| Andersen Cascade Impactor Stages | 6-stage (I–VI), cutpoints: >7, 4.7–7, 3.3–4.7, 2.1–3.3, 1.1–2.1, 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 600 × 85 × 30 mm (Lר×T) |
| Cabinet Negative Pressure | –50 to –200 Pa |
| Aerosol Chamber Negative Pressure | –90 to –120 Pa |
| Temperature Range | –40 to 99 °C ±2.5% |
| Data Storage Capacity | >100,000 test records |
| HEPA Filter Efficiency | ≥99.99% @ ≥0.3 µm |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Net Weight | ~150 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GB-KF30020 |
| Instrument Type | Aerosol Filtration Efficiency Tester |
| Filtration Efficiency Range | 0–99.999% |
| Aerosol Flow Rate | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Concentration Range | 0.001–100 mg/m³ (±1% accuracy) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Requirements | 25 °C ± 5 °C, 30 %RH ± 10 %RH |
| Brand | GBPI |
|---|---|
| Model | GB-XF1000D |
| Instrument Type | Aerosol-Based Bacterial Filtration Efficiency Tester |
| Origin | Guangdong, China |
| Manufacturer | Guangzhou GBPI Packaging Testing Instruments Co., Ltd. |
| Compliance | YY 0469–2004, YY/T 0969–2013, ASTM F2100, ASTM F2101, EN 14683 |
| Sampling Method | Dual-Channel Parallel Andersen Cascade Impactor (6-Stage) |
| Aerosol Generation | Monodisperse *Staphylococcus aureus* Bioaerosol (MMAD: 3.0 ± 0.3 µm, GSD ≤ 1.5) |
| Flow Rate (A/B) | 28.3 L/min ±2.5% |
| Spray Flow | 8–10 L/min ±2.5% |
| Peristaltic Pump Flow | 0.006–3.0 mL/min ±2.5% |
| Pressure Control Range | –20 to 300 kPa ±2.5% |
| Aerosol Chamber Negative Pressure | –90 to –120 Pa ±2.0% |
| Cabinet Negative Pressure | –50 to –200 Pa |
| Temperature Measurement Range | –40 to 99 °C ±2.5% |
| Data Storage Capacity | >100,000 test records |
| Display | 10.4″ Industrial Touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | <1500 W |
| Noise Level | <65 dB(A) |
| Net Weight | ~150 kg |
| Dimensions (Main Unit) | 1180 × 650 × 1300 mm (W×D×H) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GB-KF30010R |
| Instrument Type | Aerosol Detector |
| A-Path Sampling Flow Rate | 28.3 L/min ±2.5% (Resolution: 0.1 L/min) |
| B-Path Sampling Flow Rate | 28.3 L/min ±2.5% (Resolution: 0.1 L/min) |
| Nebulizer Flow Rate | 8–10 L/min ±2.5% (Resolution: 0.1 L/min) |
| Peristaltic Pump Flow Rate | 0.006–3.0 mL/min ±2.5% (Resolution: 0.001 mL/min) |
| Pre-Flowmeter Pressure (A/B Path) | −20 to 0 kPa ±2.5% (Resolution: 0.01 kPa) |
| Pre-Nebulizer Pressure | 0–300 kPa ±2.5% (Resolution: 0.1 kPa) |
| Ambient Temperature Range | −40 to 99 °C ±2.5% (Resolution: 0.1 °C) |
| Aerosol Chamber Negative Pressure | −90 to −120 Pa ±2.0% (Resolution: 0.1 Pa) |
| Cabinet Negative Pressure Range | −50 to −200 Pa |
| Data Storage Capacity | >100,000 test records |
| Vortex Mixer | 8 × Φ16×150 mm tubes |
| HEPA Filter Efficiency | ≥99.99% for particles ≥0.3 µm |
| Aerosol Generator Output | Mass Median Diameter (MMD) = 3.0 ± 0.3 µm, Geometric Standard Deviation (GSD) ≤1.5 |
| Andersen Six-Stage Sampler Cut-Points | Stage I >7 µm, II: 4.7–7 µm, III: 3.3–4.7 µm, IV: 2.1–3.3 µm, V: 1.1–2.1 µm, VI: 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 600 × 85 × 30 mm (L×D×H) |
| Positive Control Target | 2200 ± 500 CFU |
| Cabinet Ventilation Flow Rate | ≥5 m³/min |
| Cabinet Door Size | 1000 × 730 mm (W×D) |
| Main Unit Dimensions | 1180 × 650 × 1300 mm (W×D×H) |
| Adjustable Stand Dimensions | 1180 × 650 × 600 mm (H adjustable within ±10 cm) |
| Acoustic Noise Level | <65 dB(A) |
| Net Weight | ~150 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-KF30010E |
| Instrument Type | Aerosol Filtration Efficiency Tester |
| Filtration Efficiency Range | 0–99.999% |
| Aerosol Flow Rate | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Detection Range | 0.001–100 mg/m³ (Accuracy: ±1%) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Requirements | 25 °C ± 5 °C, 30 %RH ± 10 %RH |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GB-XF1000S |
| Instrument Category | Aerosol Detector |
| Price Range | USD 14,000 – 42,000 (based on exchange rate ~¥100,000–¥300,000) |
| Compliance Standards | YY 0469–2004, YY/T 0969–2013, ASTM F2100, ASTM F2101, EN 14683 |