BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGC9802-UO
Price RangeUSD 7,000 – 14,000
Instrument TypeBenchtop Laboratory Gas Chromatograph
Primary Application FieldEnvironmental & Medical Device Residue Testing
DetectorFlame Ionization Detector (FID), optional alternative detectors available
Detection Limit≤3×10⁻¹² g/s (n-hexadecane)
Baseline Noise≤2×10⁻¹⁴ A
Baseline Drift≤1×10⁻¹³ A/30 min
ColumnEO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional columns supported
Headspace Sampler20-position automated unit
Oven Dimensions240 × 210 × 240 mm
Temperature Range4 °C above ambient to 450 °C (1 °C increments)
Temperature Control Accuracy±0.1 °C
Temperature Gradient Uniformity±1%
Independent Temperature Zones6
Programmed Temperature RampingUp to 16 steps
Ramp Rate0.1–60 °C/min
Maximum Runtime Setting6000 min
Optional AccessoriesOil-free air generator (3 L/min, with oil/water removal)
Injection SystemSplit/splitless capillary inlet with septum purge
Data SystemDual-channel Chinese-language chromatography workstation with instrument control, real-time chromatogram display, zoom/pan functionality, automated report generation (PDF export), and manual hardware start trigger
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
ModelGC-9802B
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-purpose, with optimized configuration for residual solvent quantification
Oven Temperature Range40–400 °C
Temperature Ramp Rate0–40 °C/min
Cool-down Time~6 min (from 450 °C to 50 °C)
Carrier Gas Flow Control Range0–1200 mL/min
Carrier Gas Pressure Control Range0–970 kPa
Injector Maximum Temperature400 °C
Injector Total Flow Setting Range0–1200 mL/min
DetectorFID (Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV
ColumnOV-1701 fused-silica capillary column (50 m × 0.32 mm ID × 0.5 µm film thickness), max. operating temperature 400 °C
Data SystemIntegrated chromatography data workstation with real-time acquisition, baseline correction, peak integration, calibration curve generation, PDF report export, and audit-trail-ready operation log
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelBJ-GC128
PriceUSD 22,000 (FOB Guangdong)
Touchscreen7-inch color capacitive display
Control ArchitectureDual-mode—embedded real-time OS + PC-based bidirectional software control
EFC/EPCElectronic Flow Control / Electronic Pressure Control on all inlets and detectors
Inlet Zones2 independently heated (up to 400 °C), compatible with packed columns (φ3/φ4) and split/splitless capillary inlets
Detector OptionsFID (MDL ≤ 2.5×10⁻¹² g/s n-hexadecane, dynamic range 10⁷), TCD (sensitivity ≥ 5000 mV·mL/mg n-hexadecane, baseline drift ≤ 0.15 mV/30 min), ECD (⁶³Ni source, MDL ≤ 80 fg/s, γ-HCH ≤ 8×10⁻¹⁴ g/mL, dynamic range 10³), FPD (P: MDL ≤ 2×10⁻¹² g/s, S: ≤ 4×10⁻¹¹ g/s, methyl parathion, P/S dynamic range 10³/10²)
Oven SpecificationsInternal dimensions 280 × 310 × 160 mm
operating rangeambient +4 °C to 420 °C
Auxiliary Heaters2 additional zones (max 400 °C)
External Event Ports8 TTL-compatible digital I/O channels for valve sequencing, autosampler triggering, or thermal desorption synchronization
ConnectivityRS-232 serial port, LAN (LAM protocol), 20 method storage slots
Safety FeaturesAutomatic oven fan & heater shutdown upon column chamber door opening
Power Requirements220 VAC ±10%, 50/60 Hz, 3000 W max
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic Lab-Scale Gas Chromatograph
ModelGC-9802-P
Price RangeUSD 14,000–21,000
Instrument TypeLaboratory Gas Chromatograph
Application FieldEnvironmental & Medical Device Compliance Testing
DetectorHydrogen Flame Ionization Detector (FID)
Detection Limit≤3×10⁻¹² g/s (n-Hexadecane)
Baseline Noise≤2×10⁻¹⁴ A
Baseline Drift≤1×10⁻¹³ A/30 min
ColumnEO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm)
Oven Temperature Range4 °C above ambient to 450 °C (1 °C increments)
Temperature Control Accuracy±0.1 °C
Temperature Gradient Uniformity±1%
Independent Temperature Zones6
Programmable Temperature Ramp Stages16
Ramp Rate0.1–60 °C/min
Maximum Run Time6000 min
Injection ModeSplit/Splitless with Septum Purge
Optional Accessories20-Position Headspace Autosampler, Oil-Free Air Generator (3 L/min), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Cylinder (99.999%) with Regulator
SoftwareDual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Scroll Functionality, PDF Report Export, and Manual Trigger Button Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
CategoryDomestic HPLC System
ModelGB-LC01
Price RangeUSD 1,400 – 4,200
Instrument TypeLaboratory-Scale Analytical & Semi-Preparative HPLC System
Primary Application FieldFood Safety & Quality Control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose Organic Solvent Analysis
Oven Temperature Range40–400 °C
Maximum Ramp Rate0–40 °C/min
Cooling Rate450 °C → 50 °C in ~6 min
Carrier Gas Flow Control Range0–1200 mL/min
Carrier Gas Pressure Control Range0–970 kPa
Injector Maximum Operating Temperature400 °C
Injector Total Flow Setting Range0–1200 mL/min
DetectorFID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV
ColumnOV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 µm film thickness), Max Temp: 400 °C
DisplayIntegrated LCD with Real-Time Temperature Monitoring
Data SystemPC-Based Workstation with Chromatographic Acquisition & Quantitative Analysis Software
ComplianceQBT 2929, GB/T 10004–2008, YBB 00132002
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelGC-9802-A
Price RangeUSD 14,000–21,000
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application FieldFood Industry-Specific Analysis
Oven Temperature RangeUp to 400 °C
Ramp Rate0–40 °C/min
Injector Maximum Operating Temperature400 °C
DetectorFID (Hydrogen Flame Ionization Detector), Optional TCD/ECD/NPD
FID SensitivityMt ≤ 1 × 10⁻¹¹ g/s (n-Hexadecane)
Baseline Drift≤ 0.02 mV/h
Noise≤ 0.02 mV
ColumnOV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C
Injector TypeSplit/Splitless Capillary Injector (Optional Packed Column Injector)
Oven Dimensions240 × 210 × 240 mm
Temperature Resolution0.1 °C
Temperature Control Accuracy±0.1% of setpoint
Carrier GasHigh-Purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), Clean Air (0.4 MPa, oil-free, particle-free)
Gas Line ConnectionΦ3 mm tubing
External Dimensions500 × 550 × 500 mm (H × W × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic Lab-Scale GC
ModelGC9802-T
Instrument TypeLaboratory Gas Chromatograph
Application FieldFood Industry–Specific
Oven Temperature RangeUp to 400 °C
Oven Ramp Rate0–40 °C/min
Injector Maximum Operating TemperatureUp to 400 °C
DetectorFID (Hydrogen Flame Ionization Detector), optional alternative detectors available
FID SensitivityMt ≤ 1 × 10⁻¹¹ g/s (n-hexadecane)
Baseline Drift≤ 0.02 mV/h
Noise≤ 0.02 mV
ColumnOV-1701 capillary column (50 m × 0.32 mm × 0.5 µm), max. temp. 400 °C
Injector TypeCapillary inlet (packed column inlet optional)
Oven Dimensions240 × 210 × 240 mm (W × D × H)
Temperature Control Accuracy±0.1%
Temperature Resolution0.1 °C
Carrier GasHigh-purity N₂ (99.99%, 0.4 MPa, dried)
H₂ Supply99.99% purity, 0.4 MPa, dried
Air Supply0.4 MPa, dried and oil-free
Gas Line ConnectionΦ3 mm tubing
External Dimensions500 × 550 × 500 mm (H × W × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
ModelGC-9802A
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range40–400 °C
Temperature Ramp Rate0–40 °C/min
Cool-Down Time~6 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorFID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-Hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV
ColumnOV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C
Column Oven Dimensions240 × 210 × 240 mm
Temperature Resolution0.1 °C
Temperature Stability±0.1% of setpoint
DisplayIntegrated LCD with real-time temperature and status monitoring
Power Supply220 VAC, 50 Hz
Dimensions (H×W×D)500 × 550 × 500 mm
Compliance StandardsQB/T 2929, GB/T 10004–2008, YBB 00132002
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC9802-Y
Application ScopeGeneral-purpose EO residue testing in medical devices and packaging
DetectorFlame Ionization Detector (FID), optional alternative detectors available
Detection Limit≤3×10⁻¹² g/s (n-hexadecane)
Baseline Noise≤2×10⁻¹⁴ A
Baseline Drift≤1×10⁻¹³ A/30 min
Column30 m × 0.32 mm × 0.5 µm EO-specific capillary column (optional columns available)
Headspace Autosampler20-position
Oven Dimensions240 × 210 × 240 mm
Temperature Range4 °C above ambient to 450 °C (1 °C increments)
Temperature Control Accuracy±0.1 °C
Temperature Gradient Uniformity±1%
Independent Temperature Zones6-channel oven, inlet, detector, and auxiliary zones
Programmed Temperature RampUp to 16 steps, ramp rate 0.1–60 °C/min
Maximum Runtime Setting6000 min
Carrier GasHigh-purity nitrogen (99.999%, supplied externally)
Hydrogen Generator (optional)300 mL/min, purity ≥99.999%
Air Generator (optional)Oil-free, dehydrated & deoiled, 3 L/min
Injection SystemSplit/splitless capillary injector with septum purge
SoftwareDual-channel Chinese-language chromatography workstation with instrument control, real-time plotting, peak integration, calibration curve generation, PDF report export, and audit-ready data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelGC9802-K
Price RangeUSD 14,000–21,000
Instrument TypeLaboratory Gas Chromatograph
Application FieldEnvironmental & Medical Device Testing
DetectorHydrogen Flame Ionization Detector (FID)
Detection Limit≤3×10⁻¹² g/s (n-Hexadecane)
Baseline Noise≤2×10⁻¹⁴ A
Baseline Drift≤1×10⁻¹³ A/30 min
ColumnEO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm)
Oven Temperature Range4 °C above ambient to 450 °C (1 °C increments)
Temperature Control Accuracy±0.1 °C
Temperature Gradient Uniformity±1%
Independent Temperature Zones6
Programmable Temperature Ramping16 steps
Ramp Rate0.1–60 °C/min
Maximum Run Time6000 min
Injection ModeSplit/Splitless with Septum Purge
Optional AccessoriesZero-Air Generator (3 L/min, oil-free, dehydrated/deoiled), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Supply (99.999%, cylinder + regulator), EO Certified Reference Standards
SoftwareDual-Channel Chinese GUI Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, Audit-Trail-Ready Data Logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic
ModelGC-9802
Price RangeUSD 7,000–14,000 (FOB)
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range400 °C
Oven Ramp Rate0–40 °C/min
Oven Cooling Time~6 min (from 450 °C to 50 °C)
Carrier Gas Flow Control Range0–1200 mL/min
Carrier Gas Pressure Control Range0–970 kPa
Injector Maximum Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorFID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV
ColumnOV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 μm film thickness), Max Temp 400 °C
Injector TypeSplit/Splitless Capillary Injector (optional packed column inlet)
Oven Dimensions240 × 210 × 240 mm (W × D × H)
Temperature Resolution0.1 °C
Temperature Stability±0.1% of setpoint
Carrier GasesHigh-purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), clean oil-free air (0.4 MPa, dry)
Gas Line InterfaceΦ3 mm tubing
External Dimensions500 × 550 × 500 mm (H × W × D)
ComplianceQBT 2929, GB/T 10004–2008, YBB 00132002
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGC9802-K1
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose Quantitative Analysis of Volatile Organic Compounds
DetectorFlame Ionization Detector (FID), Optional Alternative Detectors Available
Detection Limit≤3×10⁻¹² g/s (n-Hexadecane)
Baseline Noise≤2×10⁻¹⁴ A
Baseline Drift≤1×10⁻¹³ A/30 min
ColumnEO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm), Optional Alternate Columns Supported
Autosampler20-Position Headspace Sampler
Oven Dimensions240 × 210 × 240 mm
Temperature Range4 °C above ambient to 450 °C (1 °C increments)
Temperature Control Accuracy±0.1 °C
Temperature Gradient Uniformity±1%
Independent Temperature Zones6
Programmable Temperature RampsUp to 16 steps
Ramp Rate0.1–60 °C/min
Maximum Runtime Setting6000 min
Optional AccessoriesOil-Free Air Generator (3 L/min, with oil/water removal), Hydrogen Generator (300 mL/min, 99.999% purity), High-Purity Nitrogen Cylinder (99.999%, regulator included, locally sourced)
Calibration StandardCertified Ethylene Oxide Reference Material
Data SystemDual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, and Manual Start Button Integration
Injection SystemSplit/Splitless Capillary Injector with Septum Purge Function
Safety FeaturesDual-Layer Over-Temperature Protection (Software + Hardware), Advanced Acoustic Damping
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBPI
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGC9802-K2
Price RangeUSD 7,000–14,000
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
DetectorFlame Ionization Detector (FID), optional alternative detectors
Detection Limit≤3×10⁻¹² g/s (n-hexadecane)
Baseline Noise≤2×10⁻¹⁴ A
Baseline Drift≤1×10⁻¹³ A/30 min
ColumnEO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional alternate columns
Headspace Sampler20-position
Oven Dimensions240 × 210 × 240 mm
Temperature Range4 °C above ambient to 450 °C (1 °C increments)
Temperature Control Accuracy±0.1 °C
Temperature Gradient Uniformity±1%
Independent Temperature Zones6
Programmable Temperature Ramp Stages16
Ramp Rate0.1–60 °C/min
Maximum Runtime Setting6000 min
Optional Air GeneratorOil-free, with oil/water removal, 3 L/min
Optional H₂ Generator300 mL/min, purity ≥99.999%
Carrier GasHigh-purity nitrogen (99.999%), supplied via cylinder with regulator (local procurement)
Certified EO StandardIncluded
Data SystemDual-channel Chinese-language chromatography workstation with instrument control
Injection SystemSplit/splitless capillary inlet with septum purge function
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0