Empowering Scientific Discovery

Guangzhou Yichuang Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
Model2100Plus Total Phosphorus
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method (Peroxodisulfate Digestion – Ammonium Molybdate Spectrophotometry)
Analysis Time< 10 min
Accuracy/Precision≤ ±5% FS
Resolution0.001 mg/L
Measurement Range0–2 / 0–10 / 0–50 mg/L (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-in-Time, Continuous, Manual
Verification ModesRemote, Manual, Automatic (time-based or limit-exceeded)
Signal Output4–20 mA, RS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelETI 2020 TN
Detection PrincipleAlkaline Potassium Persulfate Digestion – UV-Vis Spectrophotometry
Measurement Range0–5 / 0–10 / 0–50 mg/L TN (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-Interval, Continuous, Manual
Verification ModesRemote, Manual, Automatic (Time-Based & Threshold-Triggered)
Output Signals4–20 mA analog output
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 mm (W) × 400 mm (D) × 210 mm (H)
Cabinet Dimensions600 mm (W) × 550 mm (D) × 1750 mm (H)
Sample IntroductionMulti-channel rotary valve with low-reagent-consumption design
Fluidic PrecisionHigh-accuracy peristaltic or syringe pump (±0.5% volumetric repeatability)
Dilution CapabilityPatented intelligent dilution with auto-range switching
Data Integrity FeaturesAudit trail-enabled calibration logging, QC event timestamping, and configurable data retention
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
Model2020 Ammonia-N
Detection PrincipleSalicylate or Nessler Spectrophotometry
Measurement Range0–10 mg/L and 0–150 mg/L (expandable)
Measurement ModesCyclic, Triggered, Point, Continuous, Manual
Verification ModesRemote, Manual, Auto (time-based & threshold-triggered)
Output Signals4–20 mA, RS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 × 400 × 210 mm (W×D×H)
Cabinet Dimensions600 × 550 × 1750 mm (W×D×H)
Key FeaturesIntelligent Dilution, Auto-Range Switching, High-Precision Syringe Pump, Multi-Channel Rotary Valve Sampling, Integrated QC Protocols (Standard Spike Recovery, Blank Check, Calibration Verification), Modular Multi-Analyte Configuration Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model2100Plus CODCr
Instrument TypeOnline Analyzer
Measurement PrincipleRapid Digestion Spectrophotometry (Dichromate Oxidation)
Measurement Range0–1000 mg/L (standard), optional extended ranges up to 2000 mg/L
Accuracy±3% of reading or ±0.05 mg/L (whichever is greater)
Detection Limit0.001 mg/L
Analysis Time10–15 minutes per cycle
Batch Processing CapacityContinuous unattended operation
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Output Signals4–20 mA analog output
Operating ModesCyclic, Triggered, Point-measurement, Continuous, Manual
QC ModesRemote verification, manual verification, automated verification (time-based or threshold-triggered)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model2100Plus Online Permanganate Index (CODMn) Analyzer
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method & Redox Potentiometric Titration
Target AnalyteManganese (as KMnO₄-based oxidation capacity)
Analysis Time< 10 min per cycle
Accuracy/Precision≤ ±5% of reading
Resolution0.001 mg/L O₂ equivalent
Measurement Range0–20 mg/L (CODMn), extended ranges available
Output Signals4–20 mA analog, RS232/RS485 digital
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelETI 2020 Total Phosphorus
Detection PrinciplePotassium Persulfate Digestion–Ammonium Molybdate Spectrophotometry
Measurement Range0–2 / 0–10 / 0–50 mg/L (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-in-Time, Continuous, Manual
Verification ModesRemote, Manual, Automatic (Time-Based or Exceedance-Triggered)
Signal Output4–20 mA, RS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 mm (W) × 400 mm (D) × 210 mm (H)
Cabinet Dimensions600 mm (W) × 550 mm (D) × 1750 mm (H)
Sample CompatibilitySurface water, source water, drinking water, industrial wastewater, municipal sewage
ComplianceDesigned for routine compliance monitoring per ISO 15681-1, EPA Method 365.4, and GB/T 11893–1989
Data IntegrityAudit-trail-enabled operation logs, GLP-compliant event recording
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
Model2020 Permanganate Index Analyzer
PricingAvailable Upon Request
Detection PrinciplePotassium Permanganate Oxidation–Redox Potential Titration or Spectrophotometric Method
Measurement Range0–20 mg/L O₂ (extendable)
Measurement ModesCyclic, Controlled, Point, Continuous, Manual
Verification ModesRemote, Manual, Automatic (time-triggered & limit-exceeded)
Output Signals4–20 mA, RS232/RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 × 400 × 210 mm (W×D×H)
Cabinet Dimensions600 × 550 × 1750 mm (W×D×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTrasION 1080 ICP-MS
QuotationUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
Model2100Plus Hexavalent Chromium
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method (Diphenylcarbazide Colorimetry)
Target AnalyteChromium(VI)
Analysis Time10 min per cycle
Accuracy±5% of reading
Resolution0.001 mg/L
Detection Range0–2 mg/L and 0–5 mg/L (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-in-Time, Continuous, Manual
Verification ModesRemote Verification, Manual Verification, Automated Verification (time-based or alarm-triggered)
Output Signals4–20 mA analog output
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
ModelWCS100
Instrument TypeOnline Water Quality Analyzer
Measured ParameterspH, Conductivity, Dissolved Oxygen (DO), Turbidity, Temperature, Phycocyanin (Blue-Green Algae), Chlorophyll-a, ORP
Conductivity Range0–20,000 µS/cm
Conductivity PrincipleTwo-Electrode Conductometry
Conductivity Resolution0.01 µS/cm (at 20 µS/cm), 0.1 µS/cm (at 200 µS/cm), 1 µS/cm (at 2000 µS/cm), 10 µS/cm (at 20,000 µS/cm)
Turbidity Range0–1000 NTU / 0–4000 NTU
Turbidity Principle90° Light Scattering
Turbidity Resolution0.01 NTU
DO Range0–20 mg/L
DO PrincipleFluorescence Quenching
pH Range0–14 pH
pH Resolution0.01 pH
Temperature Range−5 to +80 °C
Temperature CompensationIntegrated NTC Sensor
Response Time (T90)<60 s (Conductivity, Turbidity, DO), T95 <10 s (pH)
Enclosure RatingIP68 (sensor + cable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (China-Made)
Model2100Plus Online Water Quality Analyzer
Instrument TypeOnline Water Quality Monitoring System
Measurable ParametersCu, Cr, Pb, Cd, Fe, Mn, Ni, Zn, Ag, Al, NH₃-N, CN⁻, Phenol, Total Phosphorus, Total Nitrogen, S²⁻, SiO₃²⁻, NO₃⁻, NO₂⁻, PO₄³⁻, K⁺, Na⁺, Ca²⁺, F⁻, Cl⁻
Analytical MethodsColorimetry (for most parameters), Ion-Selective Electrode (ISE) Potentiometry (for NH₃-N, K⁺, Na⁺, Ca²⁺, F⁻, Cl⁻)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model4100TI
PriceUpon Request
Detection PrinciplePotassium Permanganate Digestion – Redox Potential Titration
Measurement Range0–20 mg/L O₂ (expandable to higher ranges)
Measurement ModesCyclic, Controlled, Point, Continuous, Manual
Verification ModesRemote, Manual, Automatic (time-triggered or limit-exceeded triggered)
Signal Output4–20 mA, RS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Instrument Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSmart3500
PriceUpon Request
Footprint< 1 m²
InstallationSkid-mounted, plug-and-play with power & water connection
Enclosure Dimensions900 mm (W) × 750 mm (D) × 1750 mm (H)
Weight~380 kg
Analytical MethodsElectrode-based and Spectrophotometric
Measurement ModesCyclic, Triggered (Event/Threshold), Continuous, Manual, Scheduled Check
Verification ModesRemote, Manual, Auto-Triggered (Time-Based or Exceedance-Based)
OutputWired (RS485/Modbus, Ethernet) and Wireless (4G LTE, optional NB-IoT)
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Environmental ControlIntegrated HVAC system
Module ArchitectureDrawer-type, hot-swappable analytical units
ComplianceDesigned to support ISO 5667, ASTM D1129, EPA 160.1/166.1, and GB/T 32207–2015 (Chinese Standard for Online Water Quality Monitors)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model2100Plus
Instrument TypeOnline Analyzer
Measurement PrincipleAmmonia Gas-Sensing Electrode Method (Primary), Salicylate Spectrophotometry & Nessler Reagent Spectrophotometry (Optional)
Measurement Range0–1000 mg/L NH₃–N (electrode mode)
Accuracy±3% of reading or ±0.05 mg/L (whichever is greater)
Detection Limit0.001 mg/L
Analysis Time10–15 min per cycle
Sample ThroughputContinuous unattended operation
Calibration & QC ModesAutomatic, remote, and manual verification (standard addition, blank check, reference standard validation)
Output Signals4–20 mA analog output
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model2100Plus Total Nitrogen
Instrument TypeOnline Analyzer
Detection PrincipleAlkaline Potassium Persulfate Digestion – UV-Vis Spectrophotometry
Analysis Time< 10 min
Accuracy/Precision≤ ±5% FS
Resolution0.001 mg/L
Measurement Ranges0–5 / 0–10 / 0–50 mg/L (customizable extended ranges available)
Operating ModesCyclic, Trigger-Controlled, Point-Interval, Continuous, Manual
QC ModesRemote Verification, Manual Check, Automatic Verification (time-based or alarm-triggered)
Analog Output4–20 mA
Digital InterfacesRS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model5100MP
QuotationUpon Request
Detection PrincipleMicrowave-Induced Plasma Optical Emission Spectrometry (MIP-OES)
Detection Rangeppb to ppm (element-dependent)
Linear Dynamic Range≥ 4 orders of magnitude
Detection Wavelength Range176–780 nm
DetectorCCD array
Sample Throughput~5 min per multi-element analysis cycle (excluding pre-treatment)
Salt Tolerance≤ 3% TDS
Plasma GasAmbient air (no flammable gases required)
Digestion SystemIntegrated high-temperature wet digestion module
Preconcentration CapabilityOn-line solid-phase extraction (SPE) compatible
Measurement ModesCyclic, Trigger-Controlled, Point-Scan, Continuous, Manual
Verification ModesRemote, Manual, and Auto-Triggered (threshold-exceeded or time-scheduled)
Communication InterfacesRS-485, TCP/IP
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Dimensions (W×D×H)1250 × 850 × 1600 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
Model2100Plus Nickel
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method (Colorimetric)
Target AnalyteNickel (Ni²⁺)
Analysis Time10 min per cycle
Accuracy/Precision±5% of reading
Resolution0.001 mg/L
Measurement Range0–2 mg/L (extendable to multiple optional ranges)
Measurement ModesCyclic, Triggered, Fixed-point, Continuous, Manual
Verification ModesRemote, Manual, Automatic (time-based or limit-exceeded)
Output Signals4–20 mA analog output
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Show next