BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
Model2100Plus Total Phosphorus
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method (Peroxodisulfate Digestion – Ammonium Molybdate Spectrophotometry)
Analysis Time< 10 min
Accuracy/Precision≤ ±5% FS
Resolution0.001 mg/L
Measurement Range0–2 / 0–10 / 0–50 mg/L (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-in-Time, Continuous, Manual
Verification ModesRemote, Manual, Automatic (time-based or limit-exceeded)
Signal Output4–20 mA, RS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelETI 2020 TN
Detection PrincipleAlkaline Potassium Persulfate Digestion – UV-Vis Spectrophotometry
Measurement Range0–5 / 0–10 / 0–50 mg/L TN (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-Interval, Continuous, Manual
Verification ModesRemote, Manual, Automatic (Time-Based & Threshold-Triggered)
Output Signals4–20 mA analog output
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 mm (W) × 400 mm (D) × 210 mm (H)
Cabinet Dimensions600 mm (W) × 550 mm (D) × 1750 mm (H)
Sample IntroductionMulti-channel rotary valve with low-reagent-consumption design
Fluidic PrecisionHigh-accuracy peristaltic or syringe pump (±0.5% volumetric repeatability)
Dilution CapabilityPatented intelligent dilution with auto-range switching
Data Integrity FeaturesAudit trail-enabled calibration logging, QC event timestamping, and configurable data retention
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelTiH201
Instrument TypeOnline Analyzer
Measurement PrincipleWet-Chemical Derivatization + Long-Path Optical Absorption (Indophenol Blue Method)
ComplianceDesigned for continuous ambient air and industrial stack monitoring per EPA Method IO-5 (Ammonia by Indophenol Blue), ASTM D1426–22 (Standard Test Methods for Nitrogen in Water), and aligned with ISO 8573-1:2010 (for compressed air quality assessment where applicable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
Model2020 Ammonia-N
Detection PrincipleSalicylate or Nessler Spectrophotometry
Measurement Range0–10 mg/L and 0–150 mg/L (expandable)
Measurement ModesCyclic, Triggered, Point, Continuous, Manual
Verification ModesRemote, Manual, Auto (time-based & threshold-triggered)
Output Signals4–20 mA, RS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 × 400 × 210 mm (W×D×H)
Cabinet Dimensions600 × 550 × 1750 mm (W×D×H)
Key FeaturesIntelligent Dilution, Auto-Range Switching, High-Precision Syringe Pump, Multi-Channel Rotary Valve Sampling, Integrated QC Protocols (Standard Spike Recovery, Blank Check, Calibration Verification), Modular Multi-Analyte Configuration Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model2100Plus CODCr
Instrument TypeOnline Analyzer
Measurement PrincipleRapid Digestion Spectrophotometry (Dichromate Oxidation)
Measurement Range0–1000 mg/L (standard), optional extended ranges up to 2000 mg/L
Accuracy±3% of reading or ±0.05 mg/L (whichever is greater)
Detection Limit0.001 mg/L
Analysis Time10–15 minutes per cycle
Batch Processing CapacityContinuous unattended operation
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Output Signals4–20 mA analog output
Operating ModesCyclic, Triggered, Point-measurement, Continuous, Manual
QC ModesRemote verification, manual verification, automated verification (time-based or threshold-triggered)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model2100Plus Online Permanganate Index (CODMn) Analyzer
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method & Redox Potentiometric Titration
Target AnalyteManganese (as KMnO₄-based oxidation capacity)
Analysis Time< 10 min per cycle
Accuracy/Precision≤ ±5% of reading
Resolution0.001 mg/L O₂ equivalent
Measurement Range0–20 mg/L (CODMn), extended ranges available
Output Signals4–20 mA analog, RS232/RS485 digital
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPA5080
PricingUpon Request
Application DomainElectroplating Process Monitoring in Electronics, Semiconductor Fabrication, and Metal Surface Finishing
Electrode ConfigurationThree-Electrode System (Platinum Rotating Disk Working Electrode, 5 mm diameter
Temperature ControlFull-System & Flow-Path Thermal Regulation (±0.2 °C stability)
Power Supply198–242 V AC, 50 Hz ±0.5 Hz, 1000 W
Ambient Operating Range15–35 °C
Human-Machine Interface15-inch Full-Color Touchscreen (Windows OS)
Cabinet DimensionsApprox. 650 mm (W) × 750 mm (D) × 1750 mm (H)
Measurement PrincipleCyclic Voltammetric Stripping (CVS) with Potentiodynamic Scanning and Faradaic Current Integration
Automation CapabilityIntegrated Reagent Dosing Control for Organic Additive Correction Based on Real-Time Analytical Deviation
Software ComplianceAudit Trail, User Access Levels, Electronic Signature Support (FDA 21 CFR Part 11 Ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
ModelIES-200
OriginGuangdong, China
Instrument TypeContinuous Ambient Air Monitoring System
Measured ParametersSO₂, CO, NO₂, O₃, TVOC, PM₁.₀, PM₂.₅, PM₁₀
Detection PrincipleElectrochemical (SO₂/CO/NO₂/O₃), PID (TVOC), Laser Scattering (PM)
RangeSO₂ 0–2 ppm
ResolutionSO₂ 0.05 ppm
Response Time (t₉₀)SO₂/CO/NO₂/O₃ ≤90 s
Accuracy±5% of reading (gas)
Linearity Error±2% FS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelGC6010
PricingAvailable Upon Request
Measurement PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
AnalytesNon-Methane Hydrocarbons (NMHC), Benzene-Toluene-Ethylbenzene-Xylenes (BTEX)
Column ConfigurationOne Packed Column + One Empty Column (for THC) + One Dedicated Packed Column (for BTEX)
DetectorDual FID Units (Dedicated or Shared via Valve Switching)
Oven Temperature Control120 °C (BTEX), 150 °C (NMHC), ±0.5 °C Stability
Carrier GasHydrocarbon-Free Air
Analysis Cycle< 120 s (NMHC), < 180 s (BTEX)
Response Time (T90)< 20 s
Signal OutputRS-232 / RS-485 (Modbus RTU)
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Operating Ambient0–50 °C
Sample Line HeatingFull High-Temperature Zone (≥150 °C), No Cold Spots
Valving5-Position, 10-Port Rotary Valve with Patented Back-Flush Capability
ComplianceGB/T 39786–2021, HJ 1012–2018, HJ 1078–2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelETI 2020 Total Phosphorus
Detection PrinciplePotassium Persulfate Digestion–Ammonium Molybdate Spectrophotometry
Measurement Range0–2 / 0–10 / 0–50 mg/L (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-in-Time, Continuous, Manual
Verification ModesRemote, Manual, Automatic (Time-Based or Exceedance-Triggered)
Signal Output4–20 mA, RS232 / RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 mm (W) × 400 mm (D) × 210 mm (H)
Cabinet Dimensions600 mm (W) × 550 mm (D) × 1750 mm (H)
Sample CompatibilitySurface water, source water, drinking water, industrial wastewater, municipal sewage
ComplianceDesigned for routine compliance monitoring per ISO 15681-1, EPA Method 365.4, and GB/T 11893–1989
Data IntegrityAudit-trail-enabled operation logs, GLP-compliant event recording
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTiH203
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
Model2020 Permanganate Index Analyzer
PricingAvailable Upon Request
Detection PrinciplePotassium Permanganate Oxidation–Redox Potential Titration or Spectrophotometric Method
Measurement Range0–20 mg/L O₂ (extendable)
Measurement ModesCyclic, Controlled, Point, Continuous, Manual
Verification ModesRemote, Manual, Automatic (time-triggered & limit-exceeded)
Output Signals4–20 mA, RS232/RS485
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Module Dimensions490 × 400 × 210 mm (W×D×H)
Cabinet Dimensions600 × 550 × 1750 mm (W×D×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model6080 EGAC
PricingAvailable Upon Request
Sampling Flow Rate0.5 m³/h or 1.0 m³/h (critical orifice)
User Interface15" Color XGA + PCAP Touchscreen
Data CommunicationEthernet TCP/IP, USB 2.0
Relative Humidity Range10–80 % RH (non-condensing)
Operating Temperature20–30 °C
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
ModelPA4025
OriginGuangdong, China
TypeOnline Reaction Analysis System
Measurement PrinciplesPotentiometric Titration, Photometric Detection, Ion-Selective Electrode (ISE), Direct Sensor Measurement (pH, Conductivity, Refractometry)
Sample CompatibilityAqueous acidic/alkaline process streams containing HNO₃, HCl, H₂SO₄, NaOH, Na₂CO₃, NH₃ (free), Cl⁻, F⁻, ClO⁻, S₂O₈²⁻, H₂O₂, PO₄³⁻, NO₃⁻, Cu²⁺, Fe²⁺/³⁺, Ni²⁺, Cr³⁺/⁶⁺, Zn²⁺, Ag⁺, Cd²⁺, Mn²⁺, Co²⁺, Li⁺, SO₄²⁻, CN⁻, EDTA, etc.
Cabinet Dimensions~620 mm (W) × 550 mm (D) × 1735 mm (H)
Power Supply198–242 V AC, 50 Hz ±0.5 Hz
Operating Environment15–35 °C, RH ≤95% (non-condensing)
Interface15″ color touchscreen (Windows OS)
CommunicationRS232, RS485, 4–20 mA analog outputs, Ethernet
ProgrammabilityUp to 15 customizable analysis workflows
Compliance SupportASTM D129, ISO 9297, USP <731>, EPA Method 300.0, GLP/GMP-ready audit trail logging (via optional software module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Model875 SupLab
PricingAvailable Upon Request
Dimensions (Total System)1200 mm (W) × 650 mm (D) × 1750 mm (H)
Control Unit260 mm (W) × 100 mm (D) × 200 mm (H)
Sample Handling Unit450 mm (W) × 650 mm (D) × 750 mm (H)
Analytical Unit650 mm (W) × 500 mm (D) × 1550 mm (H)
Power Supply198–242 V AC, 50 Hz ± 0.5 Hz, 500 VA
Operating Environment15–30 °C, RH 45–85 % (max. daily temperature fluctuation ≤5 °C)
Touchscreen Interface10-inch full-color serial touch panel
Standard Configuration4 modular detection channels
Throughput~10 min for simultaneous quantification of up to 4 analytes in a single sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTrasION 1080 ICP-MS
QuotationUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
Model2100Plus Hexavalent Chromium
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method (Diphenylcarbazide Colorimetry)
Target AnalyteChromium(VI)
Analysis Time10 min per cycle
Accuracy±5% of reading
Resolution0.001 mg/L
Detection Range0–2 mg/L and 0–5 mg/L (selectable)
Measurement ModesCyclic, Trigger-Controlled, Point-in-Time, Continuous, Manual
Verification ModesRemote Verification, Manual Verification, Automated Verification (time-based or alarm-triggered)
Output Signals4–20 mA analog output
Power Supply220 ± 22 VAC, 50 ± 0.5 Hz
Enclosure Dimensions520 mm (W) × 380 mm (D) × 800 mm (H)
Net Weight~45 kg (excluding reagents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTONSOER® Explorer I Platform
PricingUpon Request
Measurement ScopeDesigned for spatially distributed, homogeneous process monitoring applications — e.g., Cu²⁺ and H₂SO₄ concentration monitoring in PCB manufacturing lines
Detection PrinciplesPotentiometric titration (acid-base, complexometric, precipitation, redox), photometric detection, and photometric titration
Sample ThroughputBase configuration (4 modules): ~10 min for 4 analytes
Standard configuration (8 modules)~10 min for 8 analytes
System Footprint3550 mm (W) × 650 mm (D) × 1850 mm (H)
Sample Handling Unit1250 mm (W) × 650 mm (D) × 1000 mm (H)
Analytical Unit620 mm (W) × 650 mm (D) × 1850 mm (H)
Power Supply198–242 V AC, 50 Hz ± 0.5 Hz, 2000 W
Operating Environment15–30 °C, RH 65 % ± 20 % (max daily temperature fluctuation ≤5 °C)
Control InterfaceWindows-based desktop PC with ≥23-inch display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
ModelWCS100
Instrument TypeOnline Water Quality Analyzer
Measured ParameterspH, Conductivity, Dissolved Oxygen (DO), Turbidity, Temperature, Phycocyanin (Blue-Green Algae), Chlorophyll-a, ORP
Conductivity Range0–20,000 µS/cm
Conductivity PrincipleTwo-Electrode Conductometry
Conductivity Resolution0.01 µS/cm (at 20 µS/cm), 0.1 µS/cm (at 200 µS/cm), 1 µS/cm (at 2000 µS/cm), 10 µS/cm (at 20,000 µS/cm)
Turbidity Range0–1000 NTU / 0–4000 NTU
Turbidity Principle90° Light Scattering
Turbidity Resolution0.01 NTU
DO Range0–20 mg/L
DO PrincipleFluorescence Quenching
pH Range0–14 pH
pH Resolution0.01 pH
Temperature Range−5 to +80 °C
Temperature CompensationIntegrated NTC Sensor
Response Time (T90)<60 s (Conductivity, Turbidity, DO), T95 <10 s (pH)
Enclosure RatingIP68 (sensor + cable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPA4015
PricingAvailable Upon Request
Measurable ParametersNitric Acid, Hydrochloric Acid, Sulfuric Acid, Sodium Hydroxide, Carbonates, Nitrates, Phosphates, Free Ammonia, Chlorides, Fluorides, Hypochlorites, Persulfates, Hydrogen Peroxide, and others
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPA4030
PriceUpon Request
Analyte RangeNitric Acid, Hydrochloric Acid, Sulfuric Acid, Sodium Hydroxide, Carbonates, Nitrates, Phosphates, Free Ammonia, Chlorides, Fluorides, Hypochlorites, Persulfates, Hydrogen Peroxide, and more
Dimensions620 mm (W) × 550 mm (D) × 1850 mm (H)
Power Supply198–242 V, 50 Hz ± 0.5 Hz, 350 W
Operating Environment15–30 °C, RH 65 % ± 20 % (max. daily temp. swing ≤5 °C)
Display12-inch full-color touchscreen (serial interface)
CommunicationRS485 or TCP/IP
Detection MethodsPotentiometric Titration, Photometric Titration, Direct Electrode Measurement (pH, Conductivity, Refractometry), Ion-Selective Electrode (ISE) with Standard Addition, UV-Vis Absorbance-based Quantification
Workflow ModesManual, Scheduled, Continuous, Triggered
Data ManagementAudit-trail-enabled logging, QC flagging, concentration limit alerts, reagent level monitoring, sample absence detection, leak detection
Cabinet TypeFreestanding floor-mounted enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTiH200
PricingUpon Request
Measurement PrincipleOptical Colorimetry (Long-Path Liquid-Phase Absorption Spectrophotometry)
Measurement Range0–100 / 500 / 1000 / 5000 ppb (user-selectable full-scale ranges)
Resolution0.001 ppb
Repeatability≤2% RSD
Sampling MethodIntegrated Diaphragm Pump
Response Time (t₉₀)≤150 s
Operating Temperature5–40 °C
Relative Humidity Range10–95% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
ModelPA4011
Measurement PrincipleSpectrophotometry
Analysis Time≤30 s per measurement
Sample Channels1–3 (configurable)
AnalytesCu²⁺ and/or Fe²⁺/Fe³⁺ in plating baths
Detection MethodAbsorbance-based quantification using pre-calibrated calibration curves
Reagent-Free OperationYes
Waste GenerationNone
Display7-inch full-color touchscreen
Enclosure Dimensions (PA4011, without reagent cabinet)300 mm (W) × 170 mm (D) × 400 mm (H)
Power Supply198–242 V AC, 50 Hz ±0.5 Hz, 100 W
Operating Environment15–35 °C, RH ≤95% (non-condensing)
Communication InterfacesRS232, RS485, 4–20 mA analog output, TCP/IP Ethernet
Operational ModesManual, timed cycle, continuous, and external trigger-controlled
Data ManagementTime-stamped historical storage, categorized query, exportable CSV/Excel
Alarm FunctionsConcentration limit violation detection with visual/audio alerts and configurable relay outputs
ComplianceDesigned for GLP-aligned process monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandETI
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPA5030
PriceUpon Request
Measurement PrincipleEnergy-Dispersive X-Ray Fluorescence (ED-XRF)
Sample ThroughputUp to 12 sample positions (configurable)
Elemental RangeZ = 14 (Si) to 92 (U)
Analysis Time per Sample≤ 300 s
Detection GeometryFixed vertical beam path with automated sample positioning
Power Supply198–242 V AC, 50 Hz ± 0.5 Hz, 100 W
Operating Temperature15–30 °C
Relative Humidity45–85 % RH (non-condensing)
Enclosure DimensionsApprox. 800 mm (W) × 820 mm (D) × 1710 mm (H)
User Interface15″ capacitive touch display running Windows 10 IoT Enterprise
Communication ProtocolsRS-485 (Modbus RTU), TCP/IP (Ethernet), OPC UA optional
ComplianceCE, RoHS, IEC 61000-6-3/6-4, ISO 21043 (XRF performance verification guidelines), ASTM E1621–22 (Standard Guide for XRF Analysis of Ceramic Whiteware)