| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | 0–65 °C |
| Temperature Resolution | 0.0001 K |
| Precision | ±0.1% RSD |
| Single-Sample Test Duration | ~15 min |
| Heat Capacity | ~10,500 J/K |
| Outer Water Jacket Volume | 51 L |
| Inner Water Bucket Volume | 2.3 L |
| Ignition Voltage | AC 24 V (5 s duration) |
| Oxygen Bomb Material | Ni-Cr-Mo Alloy |
| Bomb Pressure Rating | 20 MPa |
| Charging Pressure | 2.8–3.0 MPa |
| Power Supply | 220 V ±10%, 30 W |
| Dimensions (L×W×H) | 660 × 500 × 540 mm |
| Weight | ~30 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MLR-9C |
| Instrument Type | Oxygen Bomb Calorimeter |
| Temperature Range | 0–65 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Stability | < 0.2% (over 10 min) |
| Precision (Heat Capacity) | ≤ 0.1% RSD |
| Single-Sample Test Time | ≤ 20 min |
| Heat Capacity | 10,500 J/K |
| Outer Water Jacket Volume | 51 L |
| Inner Water Bucket Volume | 2.3 L |
| Oxygen Bomb Volume | 300 mL |
| Cooling Method | Semiconductor Refrigeration |
| Power Supply | 220 V ±10%, 30 W |
| Dimensions (Main Unit) | 650 × 500 × 460 mm (L×W×H) |
| Dimensions (Chiller Unit) | 510 × 380 × 425 mm (L×W×H) |
| Weight (Main Unit) | 40 kg |
| Weight (Chiller Unit) | 17 kg |
| Key | Brand: MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MLR-8000 |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 K |
| Precision | ≤0.1% RSD |
| Single-Sample Test Duration | ≤15 min (GB/T 213 compliant) |
| Heat Capacity | 10,500 J/K |
| Outer Water Jacket Volume | 30 L |
| Inner Water Bucket Volume | 2.1 L |
| Oxygen Pressure Range | 2.8–3.0 MPa |
| Ignition Voltage | 24 V DC |
| Power Consumption | <500 W |
| Dimensions (Main Unit) | 500×460×600 mm |
| Weight | 45 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MLR-7000 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibol Calorimetry |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 K |
| Precision | ±0.1% (RSD) |
| Single-Sample Test Duration | ~15 min |
| Heat Capacity | 10,500–11,000 J/K |
| Outer Water Jacket Volume | 30 L |
| Inner Water Bucket Volume | 2.1–2.3 L |
| Ignition Voltage | 24 V DC |
| Ignition Duration | 6 s |
| Operating Ambient | 5–40 °C |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | <80 W |
| Net Weight | 50 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MLR-6000 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Temperature Range | 0–40 °C (ambient variation ≤1 °C per test) |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Duration | 18–20 min (coal samples with low calorific value may require extended duration) |
| Heat Capacity | 10,500 J/K |
| Outer Water Jacket Volume | 50 L |
| Inner Bucket Volume | 2.3 L |
| Power Consumption | <500 W |
| Supply Voltage | 220 V ±10 V |
| Dimensions (W×D×H) | 450 mm × 580 mm × 480 mm |
| Ignition Voltage | 24 V |
| Compliance | GB/T 213–2003 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | ZNLRY-2005 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibolic (Constant-Temperature Jacket) |
| Temperature Range | 0 °C to 65 °C |
| Temperature Resolution | 0.0001 °C |
| Temperature Precision | ±0.003 °C |
| Single-Sample Test Duration | 18 min |
| Heat Capacity (Water Equivalent) | ~10,500 J/K |
| Inner Bucket Volume | 2000 mL |
| Outer Jacket Volume | ~20 L |
| Sample Mass Range | 0.5–1.5 g |
| Power Supply | AC 220 V, 50 Hz |
| Repeatability of Heat Capacity Calibration | <0.1% RSD |