Empowering Scientific Discovery

Hebi Minsheng Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMingShen Science
OriginHenan, China
ModelHDL-600S
Measurement PrincipleCoulometric Titration
Sample Capacity1–24 samples (batch + on-the-fly addition)
Sulfur Detection Range0.1–40%
Resolution0.001%
Temperature Control1150 °C (coal), 920 °C (oil)
Temperature Stability±3 °C
Sample Mass40–70 mg (coal), 50–100 mg (oil)
Test Duration4–8 min per sample
Power Supply220 V ±10%, 50 Hz
Max Power Consumption≤5 kW
Dimensions550 × 500 × 630 mm
Weight40 kg
ComplianceGB/T 214–2007, GB/T 214–1996
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMingShen Science
OriginHenan, China
ModelHDL-600H
Measurement PrincipleCoulometric Titration
Sulfur Range0.01–40%
Resolution0.001%
Analysis Time4–8 min (sample-dependent)
Combustion Temperature1150 °C (coal), 920 °C (heavy oil)
Temperature Control Accuracy±3 °C
Sample Mass50 mg ±5 mg (coal), 80–100 mg (heavy oil)
Sample Capacity1–24 positions per run
ComplianceGB/T 214–1996
Power Supply220 V ±10%, 50 Hz
Max. Power Consumption≤3.5 kW
Dimensions (W×D×H)1100 × 540 × 450 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMingShen Science
OriginHenan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelKZDL-9C
Measurement PrincipleCombustion-Iodometric Titration (Dry Colorimetric Method per GB/T 2462–1996)
Power Supply220 V ±20 V, 50 Hz
Max. Power Consumption≤2.5 kW
Sulfur Range0.01–99.99 wt%
Resolution0.01 wt%
Temperature Control Range300–1300 °C
Temp. Display RangeAmbient to 1300 °C
Temp. Resolution1 °C
Target Temp. Setpoint Accuracy±5 °C at 1150 °C
Heating Time~25 min to reach 1150 ±5 °C
Sample PositioningDual-Hall Element Driven Multi-Stage Auto-Sampling
Furnace DesignHorizontal High-Temperature Tube Furnace
Dimensions (L×W×H, mm)Controller: 370×350×170
Furnace580×250×270
Purifier180×245×300
Net WeightController 5 kg, Furnace 15 kg, Purifier 4 kg
ComplianceGB/T 2462–1996, ASTM D4294 (referenced methodology), ISO 8754 (equivalent combustion principle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMingShen Science
OriginHenan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelKZDL-8H
PricingUSD 1,350 (FOB)
Measurement PrincipleCoulometric Titration (ASTM D3177, GB/T 214, ISO 4299)
Sulfur Range0.1–40 wt%
Combustion Time3–9 min per sample
Furnace Temp Control1150 ± 5 °C (adjustable, SiC heating element, hot zone ≥90 mm)
Temperature Sensor AccuracyClass 0.5
Heating Rate25–30 °C/min (reaches 1200 °C in ~35 min)
Electrolytic Cell Volume450 mL (organic glass construction with sintered glass frit gas diffuser)
StabilityStable operation within 60 seconds after power-on
Power Supply220 V ± 20 V AC, 50 Hz
Dimensions (mm)Controller: 365 × 155 × 340
High-Temp Furnace580 × 250 × 270
Air Purifier Unit258 × 300 × 360
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMingShen Science
OriginHenan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelJB-2
PricingUSD 92 (based on ¥650 @ 7.07 exchange rate)
TechnologyCoulometric Titration
Air Flow Rate1000 mL/min
Power Supply220 VAC
Dimensions (L×W×H)240 × 180 × 295 mm
Core ComponentsElectromagnetic Pump, Glass Rotameter with Needle Valve, Dual-Stage Drying Tube (Silica Gel + Acid Scavenger)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMingShen Science
OriginHenan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDL-1
Detection PrincipleCoulometric Titration (per GB/T 214–2007)
Furnace Max Temp1500 °C (continuous operation at 1200 °C)
Heating Rate20–25 °C/min
Isothermal Zone80 mm (±10 °C)
Furnace TubeDual-threaded silicon carbide tube (Φ70/60 × 250/100 × 30 mm)
Reaction TubeAlumina tapered tube (Φ22/18 × 760 mm)
Temperature Control Range0–1600 °C
Power Consumption~4 kW
Supply220 V, 50 Hz
ThermocouplePt-Rh/Pt (Class I accuracy, 0–1600 °C)
Net Weight~80 kg
Dimensions (L×W×H)Furnace unit: 760×300×410 mm
Absorption unit340×150×320 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMingShen Science
OriginHenan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHDL-9
Detection PrincipleCoulometric Titration (ASTM D3177, GB/T 214, ISO 4299)
Application ScopeCoal, Coke, Iron Ore, Steel Slag, Limestone, Fly Ash, and Other Inorganic Solids
ComplianceGB/T 214–2007, ASTM D3177–22, ISO 4299:2021