Incubator Equipment
Filter
Showing 481–510 of 1126 results
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AW 400SG |
| Price Range | USD 13,500–67,500 (est.) |
| Temperature Range | Ambient + 4°C to 42°C |
| Temperature Uniformity & Stability | ±0.5°C at 37°C |
| Humidity Range | 30–100% RH |
| Chamber Capacity | 400 Petri Dishes |
| Transfer Lock Capacity | 60 Petri Dishes |
| Gas Supply Options | Single-gas (10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (premixed + pure N₂) |
| External Dimensions (W×D×H) | 1283 × 700 × 667 mm |
| Power Supply | 220 V, 50 Hz, 500 W |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AW 500SG |
| Price Range | USD 13,500–67,500 (est.) |
| Temperature Control Range | Ambient +4°C to 42°C |
| Temperature Uniformity & Stability | ±0.5°C at 37°C |
| Humidity Range | 30–100% RH |
| Chamber Capacity | 500 Petri Dishes |
| Transfer Lock Capacity | 60 Petri Dishes |
| Gas Supply Options | Single-gas (10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (premixed + pure N₂) |
| External Dimensions (W×D×H) | 1473 × 700 × 667 mm |
| Power Supply | 220 V, 50 Hz, 500 W |
| Brand | ELECTROTEK |
|---|---|
| Origin | United Kingdom |
| Model | AW200SG |
| Chamber Capacity | 220 Petri Dishes |
| Transfer Lock Capacity | 10 Petri Dishes |
| Gas Mixture | 10% H₂ + 10% CO₂ + 80% N₂ (Anaerobic) / 5% O₂ + 10% CO₂ + 85% N₂ (Microaerophilic) |
| Temperature Range | Ambient +4°C to 45°C |
| Temp. Stability | ±0.5°C at 37°C |
| Dimensions (W×D×H) | 648×635×572 mm |
| Power Supply | 220 V, 50 Hz, 300 W |
| Humidity Control | Active Condensation-Based System with Removable Water Collection Bottle |
| Safety | Integrated Earth Leakage Protection, Auto Diagnostics (Low Pressure, Leak, Airflow Anomaly) |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Numbers | MGC-100BP-2L, MGC-1500BP-2L |
| Illumination Method | Triple-sided LED lighting |
| Light Source | High-efficiency white + UV-emitting LEDs |
| Spectral Range | UV-A (315–400 nm) and photosynthetically active radiation (PAR)-optimized spectrum |
| Temperature Control Range | 0–60 °C |
| Humidity Control Range | 50–90 % RH |
| Temperature Uniformity | ±1 °C |
| Illuminance Range | 0–18,000 lx (6-step adjustable) |
| Internal Dimensions (W×D×H) | 550×400×670 mm / 600×610×830 mm |
| External Dimensions (W×D×H) | 690×800×1410 mm / 760×815×1550 mm |
| Programmability | Up to 30 multi-segment programs, each with duration from 1 min to 99 h 59 min |
| Optional CO₂ Control | Infrared CO₂ sensor, range selectable (0–5000 ppm or 0–20 % vol) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GHP-9160 / GHP-9270 |
| Power Supply | AC 220 V, 50 Hz |
| Heating Method | Water-jacketed |
| Temperature Range | RT + 5 °C to 65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Input Power | 850 W (GHP-9160) / 1350 W (GHP-9270) |
| Chamber Dimensions (W×D×H) | 500×500×650 mm (GHP-9160) / 600×600×750 mm (GHP-9270) |
| External Dimensions (W×D×H) | 695×615×950 mm (GHP-9160) / 795×715×1030 mm (GHP-9270) |
| Chamber Volume | 160 L (GHP-9160) / 270 L (GHP-9270) |
| Standard Shelves | 2 pcs |
| Timer Range | 1–9999 min |
| Safety Features | Dual-limit temperature alarm, low-water-level cutoff, audible/visual alarm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | MJ-70F-I / MJ-150F-I / MJ-250F-I / MJ-300F-I |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Range | 0–60 °C |
| Temp. Uniformity | ±0.5 °C (at high temp), ±1.0 °C (at low temp) |
| Temp. Resolution | 0.1 °C |
| Humidity Control (Model “II” only) | Yes, with microcomputer-based humidity regulation |
| Refrigerant | R134a & R406a (CFC-free, ozone-safe) |
| Internal Chamber Material | Mirror-finish stainless steel, radius-corner design |
| Air Circulation | JAKEL tube-flow centrifugal fan + engineered air duct system |
| Control System | PID temperature control with timer (max. 99 h 59 min) |
| Safety | Independent over-temperature cutoff alarm with audible/visual alert |
| UV Sterilization | Top-mounted UV-C lamp for continuous air disinfection |
| Interface Options | RS485 or USB port for data logging and external device connectivity (optional) |
| Standard Shelving | 3 adjustable stainless steel shelves |
| Chamber Volume | 70 L / 150 L / 250 L / 300 L |
| Dimensions (W×D×H, mm) | 575×605×1160 / 605×625×1350 / 705×725×1525 / 705×765×1640 |
| Net Weight | Approx. 85–145 kg (model-dependent) |
| Compliance | Designed per ISO 13485-aligned manufacturing practices |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellXpert C170 |
| Temperature Range & Accuracy | +4 °C above ambient to 50 °C |
| Temperature Uniformity | ±0.25 °C at 37 °C |
| Humidity Range & Accuracy | 90–95 % RH at 37 °C |
| Chamber Capacity | 170 L |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellXpert C170i |
| Temperature Range & Accuracy | 4–50 °C |
| Temperature Uniformity | ±0.3 °C |
| Humidity Range & Accuracy | 90–95 %RH |
| Chamber Capacity | 170 L |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellXpert C170i |
| Temperature Range & Accuracy | +4 °C above ambient to 50 °C |
| Temperature Uniformity | ±0.25 °C at 37 °C |
| Humidity Control Range & Accuracy | 90–95 % RH at 37 °C |
| Chamber Capacity | 170 L |
| Sterilization Mode | 180 °C dry-heat sterilization |
| Heating Method | Fanless, six-sided direct heating |
| Interface | Full-color capacitive touchscreen with audit trail-capable data logging |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Air-jacketed CO₂ incubated shaker |
| CO₂ Detection | Thermal Conductivity (TC) sensor |
| Temperature Range & Accuracy | +8 °C above ambient to 60 °C |
| CO₂ Concentration Range & Accuracy | 0.1–20% (±0.1% at 5% CO₂) |
| Humidity Control | Active dual-directional humidification, up to 85% rH, condensation-free operation |
| Chamber Capacity | 220 L |
| External Dimensions (W×D×H) | 77.3 × 131.8 × 80.5 cm |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | S41i |
| Temperature Range & Accuracy | +4 °C above ambient to 50 °C |
| Temperature Uniformity | ±0.25 °C at 37 °C |
| Humidity Control | 90–95 % RH at 37 °C |
| Chamber Capacity | 170 L |
| Shaking Speed Range | 25–400 rpm (25–300 rpm when stacked) |
| Shelf Dimensions | 35.6 × 61 cm |
| Maximum Vessel Size | 4 L conical flask |
| Sterilization | Integrated high-temperature decontamination cycle |
| Brand | Equitec |
|---|---|
| Origin | Spain |
| Model | EGCHS |
| Temperature Range | 4–60 °C |
| Humidity Control (HR models) | 20–90 % RH (±3 % RH) |
| Temperature Uniformity | ±1.5 °C at 27 °C, ±1.0 °C at 45 °C |
| Temperature Stability | ±0.75 °C at 27 °C, ±0.5 °C at 40 °C |
| Illumination | Programmable photoperiod with sunrise/sunset simulation (380–720 nm LED options available) |
| Controller | 4.3″ or 7″ TFT color touchscreen (4000-series), with integrated data logger (1-year storage @ 30-s intervals), MODBUS RS485, Ethernet/WiFi, GSM alarm interface (optional), USB/SD card export, GLP-compliant audit trail |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ES-20 |
| Pricing | Upon Request |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 10 mm |
| Temperature Set Range | 25–42 °C |
| Temperature Control Range | Ambient +5 to 42 °C |
| Temp/Speed Resolution | 0.1 °C / 1 rpm |
| Timer Range | 1 min – 96 h |
| Max Load Capacity | 2.5 kg |
| Display | 2-line × 16-character LCD |
| Internal Height | 270 mm |
| External Dimensions (W×L×H) | 340 × 340 × 435 mm |
| Net Weight | 15 kg |
| Power Supply | 230 V, 50–60 Hz |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Lifesciences |
| Country of Origin | Imported |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| Model | CCL |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | CCL-170-B-8-P |
| Temperature Range | 12°C below ambient to 60°C |
| Sterilization | 90°C validated moist-heat cycle (HPA certified) |
| Air Filtration | ULPA filter + ISOCIDE® antimicrobial coating + 0.2 µm CO₂ inlet filter |
| Humidity Control | Optional digital display (COA-1001/F) |
| Gas Monitoring Options | CO₂-only, CO₂/O₂, or CO₂/O₂/RH electronic analyzers (COA-2010-F to COA-2017-F) |
| Data Compliance | IQ/OQ documentation package (COA-2011-F), analog output (COA-1005/F), chart recorders (COA-2012-F to COA-2014-F) |
| Remote Monitoring | Voyager Smart Remote Monitoring Software (5250001) |
| Brand | ESCO |
|---|---|
| Origin | Singapore |
| Model | CCL-170B-8 |
| Heating Method | Direct-heat air-jacketed |
| Temperature Range | Ambient +3 to 60 °C |
| Temp. Uniformity | <±0.2 °C |
| Temp. Accuracy | <±0.1 °C |
| Temp. Recovery (after 1-min door opening) | 6 min |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% |
| CO₂ Sensor | NDIR single-beam dual-wavelength infrared |
| CO₂ Recovery | 4 min |
| Humidity Range | Ambient to 97% RH |
| Humidity Recovery (±5% from setpoint) | 15 min |
| Chamber Volume | 170 L |
| Internal Dimensions (W×D×H) | 505 × 530 × 635 mm |
| External Dimensions (W×D×H) | 660 × 660 × 900 mm |
| Power Supply | 230 V, 50/60 Hz, 3.4 A |
| Max. Power Consumption | 800 W |
| Steady-State Power @ 37 °C | 80 W |
| Net Weight | 120 kg |
| Chamber Material | 304 stainless steel, seamless one-piece construction with large-radius internal corners |
| Exterior Coating | ISOCIDE™ antimicrobial-coated galvanized steel |
| Air Filtration | ULPA filter (≥99.999% @ 0.12 µm), ISO 5 (Class 100) cleanroom-grade chamber air |
| Gas Inlet Filtration | 0.2 µm inline sterilizing filter |
| Sterilization | SwiftCon™ 90 °C wet-heat cycle with automated drying and cooling phases |
| Control System | Smartsense™ microprocessor-based PID controller with 16 MB embedded flash memory |
| Data Logging | Full-parameter event logging with timestamped records accessible via LCD interface |
| Interface | RS-485 standard output |
| Compliance | Designed for GLP/GMP environments |
| Brand | Esco |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CLM-170/240B-8-CN |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ES-80 |
| Price | Upon Request |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 20 mm |
| Temperature Set Range | 25–80 °C |
| Temperature Control Range | Ambient +5 to 80 °C |
| Temperature Setting Resolution | 0.1 °C |
| Max Load Capacity | 8 kg |
| Timer Range | 1 min – 96 h |
| Continuous Operation | Up to 168 h |
| Display | 2-line × 16-character LCD |
| Internal Height | 270 mm |
| External Dimensions (W×L×H) | 590 × 525 × 510 mm |
| Net Weight | 43 kg |
| Power Supply | 230 V, 50–60 Hz |
| Brand | Esco |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Temperature-Controlled Orbital Shaking Incubator |
| Speed Range | 30–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | Φ26 mm / Φ50 mm |
| Temperature Range | 4°C to 60°C (with refrigeration down to 4°C, i.e., up to 18°C below ambient) |
| Temperature Fluctuation | ±0.1°C |
| Temperature Uniformity | ±0.3°C (at 37°C, inner chamber) / ±0.5°C (at 37°C, full chamber) |
| Brand | Faithful |
|---|---|
| Origin | Hebei, China |
| Model | DH4000II |
| Temperature Range | RT+5–70°C |
| Temperature Uniformity | ±1.5°C |
| Capacity | 65 L |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±0.5°C |
| Heating Power | 0.45 kW |
| Chamber Material (Standard) | High-Strength Galvanized Steel |
| Chamber Material (B-Series Option) | Mirror-Finish Stainless Steel |
| Control System | Intelligent PID with Dual 4-Digit LED Display (Measured vs. Setpoint) |
| Timer Range | 0–9999 min with Delay Start & Auto-Stop |
| Safety Features | Over-Temperature Audiovisual Alarm |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Power Supply | AC 220 V, 50/60 Hz |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C140 |
| Price Range | USD 6,800–13,600 (FOB) |
| Temperature Range (lamp off) | −10 °C to +50 °C |
| Temperature Range (lamp on) | −5 °C to +55 °C |
| Temperature Stability | ±0.1 °C |
| Temp. Resolution | 0.1 °C |
| Heating Rate | +1.5 °C/min (IEC 60068-3-5) |
| Cooling Rate | −1.2 °C/min (IEC 60068-3-5) |
| Illumination Range (per shelf) | 5,000–30,000 lux |
| Photosynthetic Photon Flux (PPF) | 150–280 µmol/m²·s |
| Humidity Control Range | 10–98 %RH ±1 % |
| Humidity Source | Deionized or softened water (CaCO₃ ≤ 400 ppm), supply pressure 1–10 bar |
| Chamber Volume | 140 L |
| External Dimensions (W×D×H) | 615 × 475 × 669 mm |
| Internal Dimensions (W×D×H) | 519 × 475 × 669 mm |
| Door Configuration | Single left/right-swing door with auto-closing & thermal lock (>90 °C) |
| Sealing | Magnetic gasket |
| Shelving | Adjustable steel shelves with polymer coating |
| Lighting | Independently controllable fluorescent lamps per shelf |
| Ventilation | Dual internal fans for uniform temp./RH distribution |
| Controller | Microprocessor-based, 20-step programmable cycle, real-time monitoring of setpoint/actual values |
| Safety | Password-protected limit editing, audible/visual alarms, DIN 12880 Class 1 manual-reset overtemperature cutoff |
| Insulation | CFC-/HCFC-free polyurethane foam |
| Construction | Galvanized steel with white epoxy coating or AISI 304 stainless steel option |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FDM C140 |
| Price Range | USD 6,800–13,600 (FOB Italy) |
| Temperature Range (with Humidification) | 0 °C to +60 °C |
| Temperature Uniformity | ±0.5 °C |
| Relative Humidity Range | 10–98 % RH ±1 % RH |
| Chamber Capacity | 140 L |
| Temperature Resolution & Setpoint Increment | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Rate | +1.5 °C/min (per IEC 60068-3-5) |
| Cooling Rate | −1.2 °C/min (per IEC 60068-3-5) |
| Noise Level | <55 dB(A) |
| Power Supply | 220–230 V AC, 50 Hz |
| Construction | AISI 304 stainless steel interior & white epoxy-coated galvanized steel exterior |
| Insulation | CFC/HCFC-free polyurethane foam (≥60 mm thickness) |
| Door | Dual-hinge, auto-closing, magnetic gasket seal, thermal lockout above 90 °C |
| Shelving | Adjustable, powder-coated steel racks (2 included, max 5) |
| Controller | Dual microprocessor system (separate PID loops for temperature and humidity), 20-step standard programmability, up to 50 stored programs (optional 200-step extended firmware) |
| Humidification | Low-inertia steam generator, compatible with deionized water or softened water (CaCO₃ ≤400 ppm), supply pressure 1–10 bar |
| Safety | Manual-reset Class 1 overtemperature protection (DIN 12990), password-protected parameter limits, visual/audible alarm on deviation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | 311 |
| Temperature Range & Accuracy | Ambient +5°C to 50°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >90% rH at 37°C |
| Chamber Capacity | 184 L (6.5 cu. ft.) |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BC |
| Pricing | Upon Request |
| Brand | Genlab |
|---|---|
| Origin | United Kingdom |
| Model | LCI/9H/DIG1250 |
| Temperature Range | +8 °C to 100 °C |
| Temperature Uniformity | ±0.5 °C |
| Capacity | 1250 L |
| Construction | Powder-coated steel exterior, aluminized low-carbon steel or optional stainless-steel chamber |
| Door Configuration | Horizontal double-door |
| Heating System | Side-mounted NiCr sheathed elements with integral centrifugal blower |
| Control System | Dual-display PID microprocessor controller (setpoint & actual temperature) |
| Safety | Independent overtemperature cut-off thermostat |
| Optional Features | Interior glass door (vertical models only), castor wheels (≥650 L), adjustable chrome-plated wire shelving |
| Brand | Genlab |
|---|---|
| Origin | United Kingdom |
| Model | PRI/30 |
| Temperature Range | Ambient +5 °C to 70 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C |
| Humidity Capability | Up to 95 % RH (with optional humidification kit) |
| Internal Volume | 30 L |
| Chamber Material | Electropolished Stainless Steel (AISI 304) |
| Air Circulation | Forced-air convection via precision-balanced centrifugal fan |
| Control System | PID microprocessor controller with dual LED display (setpoint & actual temperature) |
| Timer Function | 0–99 h programmable, 8-step ramp-hold thermal profile (4 ramps + 4 holds) |
| Safety Features | Independent overtemperature cut-off (mechanical backup), audible/visual alarm, door-open detection |
| Construction | Powder-coated steel exterior, double-glazed observation window option, optional dual-door configuration |
| Standard Shelving | 2 fixed stainless steel slides + 2 removable chrome-plated wire shelves |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | GHP-9050 / GHP-9080 |
| Power Supply | AC 220 V, 50 Hz |
| Heating Method | Water-jacketed |
| Temperature Range | RT + 5 °C to 65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Input Power | 450 W (GHP-9050) / 650 W (GHP-9080) |
| Chamber Dimensions (W×D×H) | 345 × 350 × 410 mm (GHP-9050) / 400 × 400 × 500 mm (GHP-9080) |
| External Dimensions (W×D×H) | 545 × 465 × 710 mm (GHP-9050) / 595 × 525 × 800 mm (GHP-9080) |
| Net Volume | 50 L (GHP-9050) / 80 L (GHP-9080) |
| Standard Shelving | 2 adjustable stainless steel shelves |
| Timer Range | 1–9999 minutes |
| Safety Features | Independent over-temperature cutoff, low-water-level auto-shutoff, audible/visual alarm |
| Interface Options | RS485 or USB (optional) |
| Construction | Mirror-finish 304 stainless steel interior with radius-corner design |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | ES-20 |
| Speed Range | 50–250 rpm |
| Orbit Diameter | 10 mm |
| Temperature Range | 25–42 °C |
| Temperature Resolution | 0.1 °C |
| Timer Range | 1 min – 96 h |
| Max Load Capacity | 2.5 kg |
| Display | 2-line 16-character LCD |
| Input Power | 230 V, 50–60 Hz |
| Platform Compatibility | Interchangeable (P12-1000, PP-4, P6-250, PUP-12) |
| Brand | Grant |
|---|---|
| Origin | UK |
| Model | ES-80 |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 20 mm |
| Temp. Set Range | 25–80 °C |
| Temp. Control Range | Ambient +5 to 80 °C |
| Temp. Set Resolution | 0.1 °C |
| Timer Range | 1 min – 96 h |
| Max Load Capacity | 8 kg |
| Internal Height | 270 mm |
| Dimensions (W×L×H) | 590×525×510 mm |
| Net Weight | 43 kg |
| Power Supply | 230 V, 50–60 Hz |
| Continuous Operation | Up to 168 h |
| Display | 2-line × 16-character LCD |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | GRD1 |
| Temperature Range (Cooling Side) | 0–30 °C |
| Temperature Range (Heating Side) | Ambient +5 °C to 45 °C |
| Working Surface | 760 × 760 mm |
| Temperature Stability (per DIN 58966) | ±1 °C |
| Display | Digital |
| Power Supply | 220–240 V, 50/60 Hz |
| Max. Power Consumption | 2050 W |
| EMC Class | A |
| Sample Compartment Layout | 14 × 14 = 196 discrete wells |
| Integrated Data Logger | Squirrel 2020 (5-channel, with sensors at four corners and center) |
| Timer Function | Programmable 24-h dual-phase cycle with 90° orthogonal gradient rotation |