| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 6230M |
| Measurement Range | pH: –2.00 to 16.00 |
| ORP | –2000 to +2000 mV |
| Temperature | –10.0 to 130.0 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH |
| Dimensions | 241 × 86 × 72 mm |
| Weight | 0.43 kg |
| Data Storage | 40 sets |
| Calibration | Auto 3-point pH calibration |
| Temperature Compensation | Automatic and manual |
| Power Supply | AC/DC dual-mode |
| Interface | RS-232C |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 6311 |
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Dimensions | 96 × 96 × 148 mm |
| Weight | 0.96 kg |
| IP Rating | IP65 |
| Temperature Compensation | Automatic, with user-selectable sensor types (Pt1000, TH10K, BALCO 3K) |
| Output | Isolated, reversible 4–20 mA |
| Relay Outputs | Four pH/ORP control relays + one cleaning relay |
| Communication | RS-485 |
| Certifications | CE |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | JENCO Industrial Online pH Transmitter Series 691/692 |
| Measurement Range | pH: –2.00 to 16.00 |
| ORP | –2000 to +2000 mV |
| Temperature | –10.0 to 130.0 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH |
| Dimensions | 96 × 48 × 167 mm |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoCon 6500C |
| Conductivity Range | 0.00–20.00 / 200.0 / 2000 µS/cm, 0.00–20.00 / 200.0 / 2000 mS/cm |
| Resistivity Range | 0.00–20.00 MΩ·cm |
| TDS Range | 0.00 ppm–200.0 ppt |
| Resolution | 0.01/0.1/1 µS/cm, 0.1/1 mS/cm, 0.01 MΩ·cm, 0.01/0.1/1 ppm, 0.1 ppt |
| Accuracy | ±1% FS |
| Temperature Sensor | Pt1000 |
| Temp. Compensation | Automatic (with ±10.0 °C offset adjustment) or Manual |
| Operating Temp. | −10.0 to +60.0 °C |
| Humidity | 10–90% RH (non-condensing) |
| Display | Backlit LCD (44×65 mm), yellow backlight |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Outputs | Two isolated 4–20 mA analog outputs (configurable, max. 600 Ω load) |
| Relay Outputs | Two independent SPST relays (Hi/Lo alarm, hysteresis adjustable |
| Enclosure Rating | IP54 |
| Mounting | Panel mount (cutout: 92×92 mm) |
| Dimensions | 96×96×130 mm |
| Weight | 0.45 kg |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag 300-1 |
| Body Type | Integral or Remote (S/L) |
| Pipe Size Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316L SS, Hastelloy C, Tantalum, Titanium, Platinum |
| Lining Materials | PTFE (DN10–DN1000), Hard Rubber (DN50–DN2000) |
| Process Temperature | PTFE: –40 to +150°C |
| Rubber | –10 to +80°C |
| Ambient Temperature | –20 to +70°C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse/Frequency, Alarm Relay |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | InnoMag 320 |
| Pricing | Available Upon Request |
| Construction Type | Integral (S-type) or Remote (L-type) |
| Nominal Diameter Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Display | Backlit LCD |
| Installation | Flanged (custom clamp-on option available) |
| Minimum Conductivity | ≥10 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Housing Materials | Controller – Aluminum |
| Temperature Limits | PTFE Lining – –40 to +150 °C |
| Ambient Operating Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse Output, Frequency Output |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag300 |
| Nominal Diameter Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Lining Temperature Limits | PTFE: –40 to +150 °C |
| Rubber | –10 to +80 °C |
| Ambient Operating Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse, Alarm |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Housing Material | Aluminum |
| Installation Types | Integral (S-type), Remote (L-type) |
| Bidirectional Flow Measurement | Yes |
| Pressure Loss | Negligible (no obstruction) |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag 300 |
| Measurement Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Temperature Limits | PTFE Lining –40 to +150 °C |
| Ambient Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse, Alarm |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Display | Backlit LCD |
| Installation Types | Integral (S-type), Remote (L-type) |
| Pressure Loss | Negligible (no obstruction in flow path) |
| Bidirectional Flow Measurement | Yes |
| Pipe Size Range | DN10–DN2000 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biogas 5000 |
| Price | USD 6,800 (FOB UK) |
| Certification | ATEX II 2G Ex ib IIA T1 Gb, IECEx, MCERTS (under application), UKAS ISO/IEC 17025 (Accreditation No. 4533) |
| Gas Channels | CH₄, CO₂ (dual-channel NDIR), O₂, CO (H₂-compensated), H₂S (optional ranges: 0–500 / 0–5,000 / 0–10,000 ppm), NH₃, H₂ (configurable) |
| Accuracy | CH₄ & CO₂ ±0.5% vol (0–70% / 0–60%), O₂ ±1.0% vol (0–25%), CO ±2.0% FS (0–500 ppm), H₂S ±2.0% FS (0–500 ppm) |
| Response Time (T90) | CH₄/CO₂ ≤10 s, O₂ ≤20 s, CO/H₂S ≤30 s |
| Battery | Rechargeable NiMH pack, 8 h continuous operation, 3 h full charge |
| Data Storage | 10,000 sample IDs, 10,000 datasets, 10,000 event logs |
| Environmental Rating | IP65, operating temp –10 to +50 °C, RH 0–95% non-condensing |
| Dimensions | 220 × 155 × 60 mm |
| Weight | 1.5 kg |
| Pressure Range | ±500 mbar (rel.), atmospheric 500–1500 mbar (±5 mbar), vacuum limit –375 mbar |
| Flow Rate | 550 mL/min (pump), integrated well-flow probe: 0–20 L/h |
| Accessories | Removable 2.0 µm PTFE filter, optional temperature probe (–10 to +75 °C, ±0.5 °C), GPS module, Bluetooth/USB interface |
| Brand | JJS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | JJS-PCS |
| Pricing | Available Upon Request |
| Brand | JKRD |
|---|---|
| Model | BGC5000 |
| Origin | Beijing, China |
| Detector Types | PDHID, TCD, FID, FPD |
| Reproducibility | ±1% FS (major components), ±2% FS (trace components) |
| Max. Stream Count | 24 |
| Analog Outputs | 4–36 channels (4–20 mA, isolated) |
| Display | 10.4" color touchscreen |
| Oven Temp. Range | 45–125°C (±0.1°C stability) |
| Carrier Gas | He, H₂, N₂, or Ar (30–300 mL/min, ≥99.99% purity) |
| Explosion Protection | Ex d px II C T1–T4 Gb (pressurized enclosure) |
| Weight | 120 kg |
| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Model | HXPQX-500 |
| Internal Volume | 500 L |
| Cross-sectional Dimensions | 460 mm × 400 mm |
| Centerline Length of Wind Tunnel | 945 mm |
| Airflow Velocity Range | 0–7 m/s ±0.2 m/s (adjustable via frequency converter) |
| Preset Airflow Setpoints | 0.8, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 6.5 m/s |
| Control Interface | 7-inch TFT touch LCD panel |
| Rotation Capability | 360° continuous |
| Power Consumption | ≤2 kW |
| Supply Voltage | 3N 380 V, 50 Hz |
| External Dimensions | 2094 mm × 568 mm × 1034 mm |
| Exhaust System | Automated gas purging |
| Communication | RS485 / RS232, MODBUS-RTU protocol, multi-channel digital output interfaces |
| Brand | JWFroehlich |
|---|---|
| Origin | Germany |
| Model | MFL Series |
| Measurement Principle | Mass Flow Method (Standard & High-Range Modes) |
| Test Pressure Range | –0.8 to 6 bar (Standard Mode) |
| Applicable Components | Engine cylinder heads & blocks, coolant passages, low-pressure oil galleries, transmissions, fuel tanks, valve seat assemblies |
| Compliance Context | Designed for integration into automated production lines compliant with ISO 27228, VDA 19.1, and automotive OEM-specific leak test protocols (e.g., BMW QV-1010, VW TL-82304) |
| Brand | JWFroehlich |
|---|---|
| Origin | Germany |
| Model | MPS Series |
| Measurement Principle | Pressure Decay (Relative & Differential) |
| Test Pressure Range | –0.8 to 20 bar |
| Compliance | Designed for ISO 50001-aligned industrial QA/QC environments, compatible with GLP/GMP audit trails via optional software modules |
| Target Applications | Automotive powertrain component leak testing (cylinder heads, engine blocks, transmission housings, fuel rails, compressors) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | JWNP |
| Pricing | Upon Request |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA 8000Plus |
| Repeatability | <1% RSD |
| Detection Limit | 0.5 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | –4 °C to 450 °C |
| Carrier Gas Requirement | Ultra-High-Purity Gases |
| Regulatory Status | Import-Class Industrial Instrument |
| Brand | KA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KA8000Ex |
| Price Range | USD 68,000–136,000 (FOB) |
| Repeatability | <1% RSD |
| Detection Limit | <1 ppb (H₂S, COS, SO₂, CH₃SH) |
| Detector Type | Enhanced Plasma Detector (EPD) |
| Column Oven Temperature Range | −5°C to 300°C |
| Carrier Gas Requirements | Argon, Helium, or Nitrogen (inert only) |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA6000 |
| Repeatability | <1% |
| Detection Limit | 1 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | −5 °C to 300 °C |
| Carrier Gases | N₂, Ar, He |
| Compliance | Fully compatible with ASTM D7622, ISO 8573-5, USP <467>, and EPA Method TO-15/TO-17 workflows |
| Software | Embedded GC control platform with 21 CFR Part 11–compliant audit trail and GLP/GMP data integrity architecture |
| Brand | Kanomax |
|---|---|
| Model | DALT6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54×50×120 cm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Pricing | Available Upon Request |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54 × 50 × 120 cm |
| Data Storage Capacity | 1000 test records |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XG-010 |
| Conductivity Range (� | S/cm): K=0.01 cm⁻¹: 0.000–2.000 & 0.00–20.00 μS/cm |
| K=0.10 cm⁻¹ | 0.00–20.00 & 0.0–200.0 μS/cm |
| K=1.00 cm⁻¹ | 0.0–200.0 & 0–2000 μS/cm |
| K=10.0 cm⁻¹ | 0–2000 & 0–20000 μS/cm |
| Temperature Range | 5–60 °C |
| Basic Accuracy | ±2.5% F.S. |
| Resolution | 0.001 μS/cm |
| Dimensions | 145 mm × 120 mm × 145 mm (L×D×H) |
| Weight | 0.63 kg |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XG09 |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Temperature Compensation Range | 0.0–60.0 °C |
| Dimensions | 145 mm × 120 mm × 145 mm (L×D×H) |
| Weight | 0.63 kg |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Input Impedance | ≥10¹² Ω |
| Temperature Sensor | Pt1000 |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable, load <750 Ω) |
| Relay Outputs | 2 SPST (AC220 V/3 A or DC30 V/3 A) |
| Protection Rating | IP65 |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Data Retention Time | >10 years after power loss |
| Operating Ambient | 5–45 °C, ≤85% RH (non-condensing) |
| Storage Temperature | −25–55 °C (electrode storage >0 °C) |
| Sample Temp. Range | 5–60 °C |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ATP |
| Pricing | Available upon Request |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DAP |
| Pricing | Available Upon Request |
| Brand | KEYENCE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | KV-8000 |
| Pricing | Available Upon Request |
| Brand | KEYENCE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MD-F3100 / MD-F5100 |
| Pricing | Available Upon Request |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SE 706X/1-NMSN |
| Price | Upon Request |
| Resolution | 1% + 4 ppb |
| Measurement Range | 0.00–20.00 mg/L |
| Repeatability | 1% + 4 ppb |
| Stability | ±1% of reading per month |
| Temperature Compensation Range | –5 to +135 °C |
| Communication Interface | Memosens digital interface |
| Dimensions | Ø12 × 120 mm |
| Ambient Operating Temperature | 0–80 °C |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SE610 |
| Pricing | Available Upon Request |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SE670 |
| Pricing | Available Upon Request |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer | Knick Elektronik GmbH & Co. KG |
| Type | SE707 |
| Resolution | 1 ppb |
| Measurement Range | 0.00–50.00 mg/L |
| Repeatability | ±1% of reading + 1 ppb |
| Long-term Stability | ±1% of reading/year |
| Temperature Compensation Range | –5 to +121 °C |
| Output Signal | 4–20 mA (2-wire, HART-compatible) |
| Probe Length | 120 mm / 220 mm (standard variants) |
| Ambient Operating Temperature | 0–80 °C |
| Pressure Rating | 0.2–6 bar |
| Membrane Material | Fluoropolymer-based gas-permeable film |
| Sterilization Compatibility | Steam-in-place (SIP) up to 135 °C, compliant with EHEDG Guideline Doc. 8 (2022) |
| Hygienic Design | Fully drainable, crevice-free, Ra ≤ 0.8 µm polished stainless steel (1.4435 / SS316L) |