Industry-specific Instruments
Filter
Showing 391–420 of 2171 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Wine Profiling Module |
| Instrument Type | NMR-based Alcoholic Beverage Authenticity & Quality Analyzer |
| Application Domain | Wine Authentication, Origin Verification, Vintage Determination, Adulteration Screening (e.g., water dilution), Metabolite Quantification |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Globulyser |
| Detection Target | Milk Fat Globule Size Distribution |
| Automation Level | Fully Automatic |
| Analysis Time | 1–5 minutes per sample |
| Size Range | 0.20–3.0 µm (mean diameter) |
| Accuracy | ±2–4% of reading |
| Brand | Bruker |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | minispec Food & Beverage Droplet Size Analyzer |
| Automation Level | Semi-Automatic |
| Detection Scope | Milk Composition & Emulsion Droplet Size Distribution |
| Measurement Principle | Time-Domain Nuclear Magnetic Resonance (TD-NMR) |
| Validated For | Single Emulsions (O/W and W/O) and Double Emulsions (W/O/W) |
| Droplet Size Range | 0.5–10 µm (O/W), 1–30 µm (W/O) |
| Minimum Detectable Dispersed Phase | 2% (v/v) |
| Sample Prep | Minimal — No Dilution or Modification Required |
| Regulatory Alignment | Compliant with GLP practices |
| Brand | Bruker |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | minispec mq one |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor (China Region) |
| Product Category | Imported Instrument |
| Model | minispec mq-Series Polymer Analyzer |
| Pricing | Upon Request |
| Temperature Control Options | Fixed (35–45 °C), Variable (–5 to 65 °C via water bath/heater), Extended Range (–100 to 200 °C via gas-flow system) |
| Pulse Configurations | T₁, T₂, diffusion-weighted (PGSE), gradient-enabled |
| Sample Forms | Liquids, powders, films, tablets, bulk solids |
| Analysis Principle | Time-domain nuclear magnetic resonance (TD-NMR) |
| Brand | Bruker |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Minispec mqone Spin Finish Analyzer |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | minispec (mq-series platform) |
| Measurement Principle | Time-Domain Nuclear Magnetic Resonance (TD-NMR) |
| Sample Tube Options | 10 mm (mq40), 40 mm (mq-one), 50 mm (mq7.5) |
| Compliance | ASTM D8139, ISO 10565, AOAC 994.01, USP <1210> |
| Data Integrity | Audit trail-enabled software compliant with FDA 21 CFR Part 11 requirements for regulated QC/QA environments |
| Calibration | Minimal reference sample calibration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MPA II-D |
| Application | Milk and dairy product composition analysis |
| Automation | Fully automated |
| Sample Types | Liquid (raw milk, UHT milk, whey), semi-solid (yogurt, cream cheese), solid (milk powder, infant formula) |
| Optical Configuration | Transmission (for liquids via 1-mm flow cell), Diffuse reflectance (for solids/semi-solids via integrating sphere) |
| Temperature Control | Heated flow cell (40 °C), programmable sample preheating (20–40 °C) |
| Fluid Handling | Dual-pump LSM module (high-pressure homogenizing pump + peristaltic pump) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bunkoukeiki |
|---|---|
| Origin | Japan |
| Model | NIJI-2 |
| Light Source | 150 W Xenon Arc Lamp |
| Spectral Range | 300–1150 nm |
| Bandwidth Options | 5, 10, or 20 nm (FWHM) |
| Irradiance | ≥1 mW/cm² (≥40 μmol·m⁻²·s⁻¹) |
| Illuminated Area Diameter | ≥Φ3 mm |
| Optical Delivery | SMA-coupled Φ3 mm Fiber, 1 m Length |
| Calibration Sensor | Integrated Silicon Photodiode Detector |
| Control Interface | Embedded LED Indicator + Manual Shutter |
| Dimensions (W×D×H) | 230 × 295 × 414 mm (excluding protrusions |
| Compliance | Designed for ICH Q1B, ISO 10993-12, and USP <1107> photostability protocols |
| Brand | CA (France) |
|---|---|
| Origin | France |
| Model | CA8220 |
| Voltage Range | 6–600 V AC/DC (True RMS), ±(0.5% + 2 digits) |
| Current Range | 100 mA–6500 A AC (clamp-dependent), ±(0.5% + 1 digit) |
| Frequency Range | 40–70 Hz |
| THD Measurement | up to 50th harmonic (voltage & current), THD-F and THD-R |
| Motor Speed | 6–120,000 rpm, ±0.5% |
| Temperature (Pt100) | −200 °C to +850 °C, ±(1% + 10 digits) |
| Resistance | 0.0–2000 Ω, ±(0.5% + 2 Ω) |
| Display | 173-segment backlit LCD |
| Data Logging | Internal storage with time-stamped records |
| Connectivity | RS232 & USB |
| Safety Rating | IEC 61010-1, CAT III 600 V |
| Ingress Protection | IP54 |
| Dimensions | 211 × 108 × 60 mm |
| Weight | 840 g (with batteries) |
| Brand | Calpas |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Calpas R |
| Price Range | USD 85,000 – 170,000 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV-HT |
| Temperature Control Range | 40 °C to 150 °C |
| Kinematic Viscosity Measurement Range | 0.5 mm²/s (cSt) to 10,000 mm²/s (cSt) |
| Compliance Standards | AASHTO T201, ASTM D2170, ASTM D445 |
| Throughput | Up to 12 samples/hour |
| Software | VISCPRO® PC (supports up to 4 instruments per workstation) |
| Sample Preheater | Adjustable |
| Waste Line Heater | Integrated |
| Solvent Inlets | Dual standard ports |
| Calibration | Single-point temperature calibration capability |
| Capillary Exchange | Tool-free, operator-performed in minutes |
| Brand | LUSTER |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CartonHERO-650B |
| Pricing | Available Upon Request |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CEL-QPCE3000 |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm (optional 200–2500 nm) |
| Wavelength Step Resolution | ≥1 nm, continuously adjustable |
| QE/IPCE Repeatability (RSI) | <0.3% (photocurrent) |
| Chopping Frequency | 5–1000 Hz |
| Monochromator | 300 mm focal length, asymmetric Czerny-Turner design, aberration-corrected, nitrogen-purged port |
| Light Source | 500 W Xe lamp (Osram), intensity stability <0.01% |
| Detector | UV-enhanced Si photodiode (300–1100 nm) |
| Electrochemical Integration | Compatible with Ivium and other CE-compliant potentiostats |
| Sample Stage | Motorized dual-position stage (reference + sample), EMI-shielded enclosure |
| Optional Bias Light | Single- or dual-channel LED/laser bias sources |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Z61GP |
| Price Range | USD 13,500 – 40,500 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LM-8 |
| Pricing | Available Upon Request |
| Sample Size | 100 × 100 mm |
| Test Stations | 2–8 simultaneous samples |
| Turntable Center-to-Sample Center Distance | 195 mm |
| Rated Turntable Speed | 300 ± 10% rpm |
| Eccentricity | e = 22.5 mm |
| Fixture Internal Diameter | Ø83 mm |
| Fixture Internal Height | 25.5 mm |
| Effective Abraded Area per Sample | ≈54 mm² |
| Motor Power | 1.5 kW |
| Power Supply | 380 V ± 10%, 50 Hz ± 10%, 3-phase 4-wire |
| Brand | CFR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFR F-5 |
| Configuration | Benchtop |
| Measurement Parameter | Diesel Cetane Number |
| Compliance Standard | ASTM D613, GB/T 386–1991, ASTM D975 (Arbitration Method) |
| Key | Brand: CFR |
|---|---|
| Origin | USA |
| Model | F1/F2 |
| Application | Gasoline Octane Number (RON/MON) Determination |
| Configuration | Benchtop |
| Standards Compliance | ASTM D2699, ASTM D2700, ISO 5164, ISO 5163, GB/T 5487, GB/T 503 |
| Compression Ratio Range | 4:1 to 18:1 (continuously adjustable) |
| Ignition Timing | 13° BTDC (capacitor discharge system) |
| Knock Detection | Factory-calibrated analog knock meter (0–100 scale), magnetic reluctance sensor mounted in combustion chamber |
| Lubrication | Pressure-fed, external oil pump with filtration, cooling, and flow monitoring |
| Cooling System | Thermosiphon jacketed cylinder with boiling/condensation recirculation |
| Air Intake Humidity Control | 25–50 g H₂O per lb dry air (ASTM-compliant) |
| Safety Interlocks | Low oil pressure, low coolant pressure, low voltage, motor overload |
| Drive Motor | Three-phase synchronous/reluctance motor (constant-speed operation) |
| Carburetor | Single-venturi, level-viewable fuel bowl |
| Cylinder Head | Monolithic, integrated design for thermal stability and measurement repeatability |
| Crankcase | CFR 48D cast iron box-type, service-accessible side and gear covers |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | SRZ-400A |
| Standards Compliance | GB/T 3682–2000 Method A, ISO 1133:1997 |
| Temperature Range | 80–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Barrel ID | 9.550 ± 0.025 mm |
| Piston Head Diameter | 9.475 ± 0.015 mm |
| Piston Head Length | 6.35 ± 0.1 mm |
| Die Capillary Diameter | 2.095 ± 0.005 mm |
| Stroke Interval | 30 mm |
| Position Control Accuracy | ±0.1 mm |
| Max Power Consumption | < 500 W |
| Temperature Recovery Time | ≤ 4 min |
| Net Weight | 50 kg |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0059A |
| Power Consumption | 1200 W |
| Temperature Control Range | Ambient to 250 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Method | Metal Bath |
| Pressure Regulation | Precision Needle Valve + Imported Differential Pressure Gauge |
| Vacuum System | Integrated Vacuum Pump with Buffer Chamber |
| Compliance | NB/SH/T 0059–2010 Method A, ASTM D5800 |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0168 |
| Standard Light Source | 220 V, 100 W, frosted milky incandescent lamp with color temperature 2750 ± 50 K |
| Color Scale Range | ASTM D1500-equivalent 1–25 color numbers (glass reference standards) |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Power Consumption | 110 W |
| Dimensions (L×W×H) | 350 × 250 × 400 mm |
| Net Weight | 15 kg |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0629 |
| Temperature Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤3500 W |
| Dimensions (L×W×H) | 920×740×930 mm |
| Operating Environment | 20–25 °C, RH ≤80% |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SYD-0689A |
| Detection Type | Total Sulfur |
| Portability | Benchtop (Non-portable) |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Measurement Range | 0.1 mg/kg to 10,000 mg/kg (equivalent to 0.00001–1.0 wt%) |
| Detection Limit | 0.05 mg/kg |
| Sample Forms | Liquid (standard), optional solid/gas with dual-furnace and nitrogen deactivation accessories |
| PMT Voltage Range | DC 400–900 V |
| Calibration Linearity | R² ≥ 0.9995 |
| Temperature Control Range & Accuracy | Ambient to 1300 °C, ±1 °C |
| Repeatability (RSD) | ≤3% across 0.2–5000 mg/kg range |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0722D |
| Control System | Computer-controlled with programmable soaking, washing, centrifugation, and drying cycles |
| Centrifuge Speed | ≥8,000 rpm |
| Extraction Environment | Fully enclosed, solvent-recovery-integrated system |
| Solvent Heating & Ultrasonic Assistance | Integrated in wash chamber |
| Drying Capability | Hot-air drying of aggregates and mineral filler |
| Sample Throughput | Complete asphalt extraction from standard 1,000–1,500 g asphalt mixture specimens within ≤60 minutes |
| Compliance Framework | Designed to support ASTM D2172, AASHTO T164, and GB/T 11893–2022 test protocols |
| Optional Accessories | Motorized lift rotary evaporator, custom glassware cleaning fixtures |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0728 |
| Load Range | 0–300 N |
| Load Measurement Accuracy | ≤ ±0.1 N |
| Deflection Measurement Range | 0–20 mm (mid-span) |
| Deflection Resolution | ≤ ±0.01 mm |
| Temperature Control Range | −2 °C to 40 °C |
| Temperature Stability | ≤ ±0.5 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Total Power Consumption | 3.2 kW |
| Dimensions (L×W×H) | 810 × 540 × 1300 mm |
| Net Weight | 86 kg |
| Communication Interface | RS232 serial port |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0777 |
| Test Temperature Range | 30–60 °C (±1 °C) |
| Applied Pore Water Pressure | 200–400 kPa (±30 kPa) |
| Sample Dimensions | Ø100–150 mm × 25–150 mm (diameter × height) |
| Power Supply | AC 220 V ±10%, 50 Hz, 1500 W |
| Operating Environment | 5–35 °C, RH ≤80% |
| Dimensions (L×W×H) | 530 × 530 × 1200 mm |
| Net Weight | 260 kg |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-11132 |
| Pricing | Available Upon Request |
| Power Supply | AC (220 ± 5%) V, 50 Hz |
| Pressure Regulation Range | 0–400 kPa |
| Gas Supply | External N₂ cylinder or compressed air source (user-provided) |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-12579 |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Air Flow Rate | (94 ± 5) mL/min (adjustable) |
| Temperature Control Range | 5–99.9 °C (low-temp bath) |
| Temperature Stability | ±0.5 °C |
| Timing Options | 5 min and 10 min |
| Operating Environment | 15–35 °C, ≤85% RH |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-1884A |
| Pricing | Available Upon Request |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-260A |
| Power Rating | 1000 W × 2 (dual heating units) |
| Input Voltage | AC (220 ± 10%) V, 50 Hz |
| Heating Control | Bidirectional thyristor-based stepless voltage regulation |
| Test Capacity | Dual-sample parallel determination |
| Compliance | GB/T 260–2016, GB/T 512–2013 |