| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | Pharma Mini |
| Motor Power | 400 W |
| Speed Range | 10–360 rpm |
| Screw Configuration | Conical Co-rotating or Counter-rotating |
| Max Operating Temperature | 280 °C |
| Heating Time (22–170 °C) | < 10 min |
| Free Volume | 3 g (4 mL) |
| Screw Material | Medical-Grade Stainless Steel 1.4112 (AISI 440B) |
| Barrel Material | High-Performance Pharmaceutical-Grade Stainless Steel M340 |
| IP Rating | IP54 |
| Production Capacity | Up to 100 g/h |
| Controller | Touchscreen with User-Level Access Control and Password Protection |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F85930 |
| Pricing | Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1064Defender™ Handheld Raman Analyzer |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 1600 |
| Pricing | Available Upon Request |
| Power Supply | 220 V / 50 Hz |
| Operating Temperature | 5–50 °C |
| Storage Temperature | –10–70 °C |
| Sulfur Detection Range | 1 ppb to 100 wt% (user-configurable) |
| Resolution | 1 ppb |
| Accuracy | ±2% of full scale |
| Repeatability | ±1% of full scale |
| Linearity | ±1% of full scale |
| Drift | <1% FS/24 h |
| Temperature Coefficient | 0.01% / °C |
| Analysis Time | <1 s per measurement |
| Interference Resistance | None (non-dispersive UV fluorescence principle) |
| Alarm Outputs | Solid-state 30 mA @ 24 V DC or mechanical relay 5 A @ 220 V AC (NO/NC configurable) |
| Display | 128 × 64 pixel monochrome LCD |
| Analog Output | Standard 4–20 mA (single channel), optional dual 4–20 mA |
| Optional Accessories | Auto-calibration module, heated sample probe & flow regulator, chemiluminescence trigger interface, data logger, process heater & temperature controller, RS-232/RS-485 serial interface, signal junction box |
| Hazardous Area Certification Options | Class I, Div. 2, Groups A–D (1700-series enclosure) |
| Dimensions (W×D×H) | 127 × 30 × 76 cm |
| Weight | 90 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Horizon FTS |
| Pricing | Available Upon Request |
| Brand | Optec |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TIR-4 |
| Pricing | Available Upon Request |
| Spectral Range | 8–14 µm |
| Spectral Channels | 4 (8.2–9.4 µm, 9.4–10.6 µm, 10.6–11.8 µm, 11.8–13.0 µm) |
| Field of View | 53° zenith angle |
| Calibration Source | Integrated high-stability blackbody (±0.15 K uncertainty at 300 K) |
| Remote Operation | Yes (RS-485/Modbus & optional LTE/WiFi module) |
| UAV-Mountable | Yes (< 1.2 kg, 120 × 100 × 85 mm) |
| Data Logging | Internal SD card + real-time telemetry |
| Compliance | ISO 9078:2022 (Radiometric calibration traceability), ASTM E1933-21 (Infrared thermometry for surface temperature), GLP-compliant metadata tagging |
| Brand | Linetronic |
|---|---|
| Origin | Switzerland |
| Model | ThermoTwin SA |
| Temperature Range | +80 °C to −50 °C |
| Bath Temperature Range | −10 °C to +50 °C |
| Heating Rate | 3 °C/min |
| Cooling Rate | 1 °C/min |
| Temperature Sensor | PT100 Class A |
| Compliance | CE Marked |
| Instrument Form Factor | Benchtop with Dual Sample Positions |
| Cooling System | CFC-free Air-Cooled Compressor |
| Sample Chamber | Dry, Jacketed Cooling Environment |
| Data Output | Real-time Slope Calculation (Q = ΔT/Δt), Shukoff & Tempering Curve Generation |
| Brand | TAMASAKI (Kyoto) |
|---|---|
| Origin | Japan |
| Model | M6×1.0 GP2-DS2 |
| Thread Type | Metric ISO/JIS General Purpose (M), Pitch: 1.0 mm |
| Class | JIS B 1341 Grade 2 (equivalent to ISO 965-3 Class 2H/2G) |
| Nominal Size | M6×1.0 |
| Gage Body Material | Gauge Steel (SUJ2 hardened and stabilized) |
| Sleeve Material | Anodized Aluminum Alloy |
| Mass | 27.7 g |
| Compliance | JIS B 1341, ISO 965-3, ISO 1502 |
| Application Scope | In-process verification of threaded holes in semiconductor packaging substrates, printed electronics interconnect components, and fine-pitch SMT fixture hardware |
| Brand | THT |
|---|---|
| Origin | United Kingdom |
| Model | ES-ARC |
| Compliance | ASTM E698, ISO 22517, UN Test Series 3 (H.2, H.3), IEC 60079-10-1 |
| Temperature Range | Ambient to 500 °C |
| Pressure Rating | Up to 200 bar |
| Sample Mass Capacity | 0.1–10 g |
| Heat Flow Resolution | <0.1 mW |
| Adiabatic Tracking Accuracy | ±0.02 °C/min |
| Data Acquisition Rate | 1 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thwing-Albert |
| Price Range | USD $13,500 – $67,500 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FP-260 |
| Price Range | USD 13,500 – 68,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 106 |
| Pricing | Upon Request |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ProTear |
| Measurement Principle | Elmendorf Pendulum Tear Method |
| Compliance Standards | ASTM D1922, D1424, D295, D751 |
| Display | 4-line × 16-character LCD, multi-angle viewing |
| Accuracy | ±0.2% of pendulum capacity |
| Sample ID Input | 13-character alphanumeric |
| Data Storage | Up to 99 test results |
| Statistical Functions | Mean, Std. Deviation, Min/Max, Variance |
| Units | gf, lbf, mN, % of pendulum capacity |
| Fixture | Pneumatically actuated clamping |
| Pendulum Release | Pneumatic |
| Power Supply | 220–230 V ±10%, 50 Hz |
| Power Consumption | ≤10 W |
| Dimensions (L×W×D) | 578 × 483 × 398 mm |
| Operating Temp. | 10–50 °C |
| Storage Temp. | −25–70 °C |
| Sample Compatibility | Paper, board, film, foil, nonwovens, coated fabrics, packaging laminates |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-10 |
| Sealing Temperature Range | 20–400 °C (±0.15 °C accuracy) |
| Temperature Resolution | ±0.1 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms–99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | 362 kg (1000 lbf) total capacity, ±0.09 kg (±0.2 lbf) accuracy & repeatability |
| Peel Load Cell | 11.34 kg (25 lbf), 0.1% FS accuracy, ASTM E-4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Range | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794.2 mm |
| Weight | 79.3 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-2 |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 200 ms–99 s (with 10 ms resolution at low load |
| Time Accuracy | ±25 ms |
| Time Repeatability | ±50 ms |
| Jaw Length | Up to 304.8 mm (12 in) |
| Jaw Width | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Options | Flat, Grooved, Custom or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended: 90 psi) |
| Dimensions (W×D×H) | 584.2 × 400 × 620 mm |
| Weight | 72.5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thwing-Albert Vantage |
| Price Range | USD 14,000 – 70,000 |
| Load Capacity | 1 kN (225 lbf) |
| Peel Angle | Fixed 90° |
| Standard Compliance | ASTM D6862, ASTM D6252, PSTC-1A |
| Fixture Part No. | 1750–3005 |
| Sample Type | Flexible Adhered Substrates (e.g., pressure-sensitive tapes, laminates, labels, medical adhesives) |
| Test Mode | Tensile Peel |
| Grip Configuration | Upper Movable Jaw + Lower Motorized Crosshead with Angularly Constrained Specimen Stage |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TE-A420 |
| Price | USD 630 (FOB) |
| Detection Range | 0–9999 RLU |
| Limit of Detection | ≤1.0 CFU/mL |
| Measurement Precision | 2×10⁻¹⁸ mol ATP |
| Background Noise | ≤2 RLU |
| Assay Time | 10 s per sample |
| Data Storage Capacity | ≥2000 records |
| Interface | USB |
| Temperature Operating Range | 5–40 °C |
| Relative Humidity Range | 20–85 % RH |
| Configurable Alert Thresholds | ≥100 user-defined limits |
| Interference Tolerance | ±5 RLU or ±5 % |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | GWF-6JA |
| Particle Detection Principle | Laser Light Obscuration (LO) |
| Measurement Channels | 20 µm, 15–25 µm, ≥25 µm, 25–50 µm, 51–100 µm, >100 µm |
| Sizing Range | 5–200 µm |
| Count Range | 0–65,535 particles per sample |
| Sample Volumes | 5 mL, 100 mL, 475 mL, 500 mL, or full-volume aspiration |
| Accuracy | ±10% of specified value |
| Relative Standard Deviation (RSD) | ≤2% (for standard latex particles ≥1500 particles/mL) |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤45 W |
| Stirring Speed | 0–2000 rpm, paddle-type, non-contact |
| Operating Temperature | 10–40 °C |
| Dimensions | 325 × 320 × 460 mm |
| Weight | 22 kg |
| Compliance | Designed to meet Chinese Pharmacopoeia (ChP) General Chapter 0903, USP <788>, and ISO 8573-1 (particulate contamination in compressed gases—adapted for liquid-phase validation) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-7JA |
| Pricing | Available Upon Request |
| Light Source | High-Performance Laser |
| Detection Principle | Light Obscuration (LO) |
| Sample Compatibility | Colorless & Colored Clear Liquids, Organic Solvents, Oil-Based Formulations |
| Sample Volume Range | 1–6000 mL (0.1 mL incremental step) |
| Volume Accuracy | ≤ ±0.5% (2–1000 mL) |
| Syringe Options | 5 mL, 10 mL, 25 mL |
| Flow Rate | 5–160 mL/min (user-adjustable) |
| Particle Size Channels | 2–3 µm, 3–4 µm, 4–6 µm, 5–6 µm, ≥5 µm, ≥10 µm, 15–25 µm, ≥25 µm, 25–50 µm, 51–100 µm, >100 µm, 20 µm |
| Customizable Channel Range | 1–500 µm (segmented selection) |
| Count Range | 0–999,999 particles per sample |
| Counting Accuracy | < ±5% of certified reference value |
| RSD | < 1.5% (for standard particles ≥1000 counts) |
| Coincidence Error | < 5% at 10,000 particles/mL |
| Stirring Mechanism | Frictionless Propeller-Type Agitator, 0–2000 rpm (adjustable) |
| Display | Large Backlit LCD with Multi-Channel Real-Time Data & Histogram Overlay |
| Preloaded Database | >300 USP/ChP-Listed Pharmaceuticals & Medical Devices |
| Compliance | GB 8368–2018, Chinese Pharmacopoeia (2020 Edition), ISO 21501-4, USP <788>, USP <789>, EP 2.9.19 |
| Connectivity | RS232 Interface for LIMS/Lab Platform Integration |
| Power Supply | AC 220 V ±10%, 50 Hz, <100 W |
| Operating Temperature | 10–40 °C |
| Wetted Materials | 316L Stainless Steel + PTFE (for syringe, slit, and fluidic path) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-8JA |
| Pricing | Available Upon Request |
| Principle | Light Obscuration (LO) with Laser Detection |
| Compliance | Fully Aligned with Chinese Pharmacopoeia (ChP) 2020 Edition, General Chapter 0903 |
| Sample Types | Sterile Injectable Solutions, Lyophilized Powders, Concentrated Injection Solutions |
| Detection Range | 1–500 µm (Configurable Channel Segments) |
| Channel Settings | ≥2 µm, 4–6 µm, ≥5 µm, ≥8 µm, ≥10 µm, ≥12 µm, ≥25 µm, ≥100 µm |
| Count Range | 0–9,999,999 particles per sample |
| Max. Particle Concentration | <10,000 particles/mL |
| Sample Volume | 0.2–1000 mL (5 mL accuracy: ±0.5%) |
| Flow Rate | 5–80 mL/min (adjustable) |
| Measurement Accuracy | ±10% of reference value |
| Channel Resolution | >95% |
| RSD | <2% (for standard latex particles ≥1000 particles/mL) |
| Stirring Speed | 0–2000 rpm (propeller-type, frictionless, programmable) |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤100 W |
| Display | Large LCD with Chinese GUI |
| Data Handling | Onboard storage, USB export, LAN connectivity, optional integration with LIMS or ELN platforms |
| Preloaded Drug Library | >300 ChP-listed injectables |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | GWF-8JD |
| Pricing | Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-8JDS |
| Pricing | Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GWF-9DW |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-A1 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | GWF-A1 |
| Pricing | Available Upon Request |
| Light Source | High-Stability Laser Diode with Optical Power Compensation Circuit |
| Sample Compatibility | Colorless & Colored Clear Liquids, Organic Solvents, Oil-Based Matrices, Weakly Acidic/Alkaline Solutions |
| Fluidic Path Materials | Imported 316L Stainless Steel & PTFE |
| Particle Size Range | 1–500 µm |
| Channel Resolution | >95% |
| Counting Accuracy | ±5% of Reference Value |
| Relative Standard Deviation (RSD) | <1.5% (for standard particles ≥1000 particles/mL) |
| Minimum Detectable Concentration | 18,000 particles/mL |
| Adjustable Sampling Volume | 0.2–1000 mL (0.1 mL resolution, accuracy <±0.5%) |
| Flow Rate Control | 5–80 mL/min (programmable) |
| Stirring Speed | 0–1000 rpm |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, <80 W |
| Data Interfaces | RS232, USB Storage, Thermal Printer Port |
| Software Platform | Embedded Android OS with Multi-Tier User Authentication & Audit Trail Support |
| Calibration Standards | USP <788>, USP <789>, ChP (Chinese Pharmacopoeia) Vol. IV, ISO 21510, EP 2.9.19 |
| Data Storage | Local SQLite Database with Statistical Analysis Engine |
| Compliance Features | Electronic Signature Support, User Access Logs, Data Integrity Controls per ALCOA+ Principles |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GWF-A2 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg), ±1% (>400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Regulatory Status | Certified Medical Device per Chinese NMPA Class II requirements |
| Compliance | Meets pharmacopoeial specifications in Chinese Pharmacopoeia (2020 Edition), including for injectables, ophthalmic preparations, and osmotic diuretics |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C-1 |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–70 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤ 400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Ambient Temp. | 10–30 °C |
| Ambient Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Dimensions | 220 × 210 × 360 mm |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30D |
| Measurement Principle | Freezing Point Depression |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 90 s |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 10–30 °C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Compliance Support | Chinese Pharmacopoeia (ChP) injection database built-in |
| Data Interface | RS232 |
| Software Features | User permission management, audit-trail-capable data storage, configurable pass/fail criteria, multi-format print output |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30DS |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 1.5 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |