| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | PBL |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | RABS |
| Pricing | Available Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RTP |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | STI Series |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | STP |
| Pricing | Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Origin | Yes |
| Model | 302 |
| Pricing | Available Upon Request |
| Emissivity Range | 0.01–1.00 |
| Spectral Band | 5–14 µm |
| Temperature Accuracy | ±0.015 °C |
| Response Time | 500 ms |
| Emissivity Readout Interval | 3 s |
| Operating Ambient Temperature | 24–28 °C (Optimal at 26 °C) |
| Operating Humidity | 10–95% RH (Non-condensing) |
| Sample Test Temperature | 34.0 °C |
| Calibration Blackbody Diameter | φ60 ±1 mm |
| Blackbody Setpoint | 34.0 °C |
| Dimensions (H×W×D) | 18.7 × 18.4 × 15.0 cm |
| Weight | 3.2 kg |
| Power Supply | AC 110 V / 220 V |
| Standard Accessory | Certified 0.95 Emissivity Blackbody Reference (at 26 °C) |
| Optional Accessory | PC Control Software & USB/RS-232 Interface Module |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TCC-B |
| Temperature Range | Down to –90 °C |
| Bath Tank Material | Stainless Steel |
| Temperature Stability | ±0.05 °C |
| Communication Interface | RS232 Serial Port |
| Software | Included Free PC Control Software |
| Distribution Type | Authorized Distributor (Non-Manufacturer) |
| Import Status | Imported Instrument |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TFBT |
| Dimensions (L×W×H) | 280 × 350 × 620 mm |
| Weight | 11 kg |
| Power Supply | 85–264 VAC, 47–63 Hz, 40 W |
| Temperature Measurement | Range unspecified, Resolution 0.1 °C, Accuracy ±0.05 °C (IEC 751) |
| Pressure Measurement | Range 0–1500 mbar, Accuracy ±1 mbar, Nonlinearity 0.5 mbar |
| Volume Measurement | Range 0–300 mL, Linearity ±0.2 mL, Resolution ±0.5 mL |
| Timer Accuracy | ±0.001 s |
| FBT Index Range | 1.0–30 (lower values indicate better filterability) |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TFBT |
| Standards Compliance | ASTM D2068, IP 387, SH/T 0895 |
| Test Methods | Integrated Method A & Method B |
| Display | 7-inch capacitive touchscreen with real-time pressure/flow/temperature curves |
| User Interface | Step-by-step graphical guidance |
| Calibration | Fully electronic (no mechanical adjustment required) |
| Output | Integrated thermal printer |
| Temperature Control | PID-regulated heating block (ambient to 100 °C, ±0.5 °C stability) |
| Flow Measurement | High-precision mass flow sensor (range: 0–200 mL/min, resolution: 0.1 mL/min) |
| Pressure Sensing | Digital differential pressure transducer (0–1000 kPa, accuracy: ±0.5% FS) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TV12LT |
| Temperature Range | −42 °C to +80 °C |
| Display Resolution | 0.01 °C (0.001 °C optional) |
| Test Positions | 4 |
| Bath Volume | 15 L |
| Construction Material | Stainless Steel |
| Illumination | Integrated LED Lighting |
| Cooling System | Built-in Compressor-Based Cooling |
| Observation Window | Heated, Removable Outer Pane for Easy Cleaning |
| Interface | RS232 for PC-based Temperature Programming and Data Logging |
| Standards Compliance | ASTM D445, ASTM D446, ASTM D1655, ASTM D2270, IP 71, EN ISO 3104, ISO 3105, DIN 51562 |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TV16000 |
| Temperature Range | 10–60 °C |
| Temperature Stability | ±0.005 °C |
| Bath Volume | 160 L |
| Temperature Resolution | 0.001 °C |
| Brand | TANAKA (Japan) |
|---|---|
| Origin | Japan |
| Model | AAP-6 |
| Standards Compliance | ASTM D611, ISO 2977, GB/T 262 |
| Temperature Range | Ambient to 160 °C |
| Heating Rate | 10 °C/min (up to 10 °C below expected aniline point), then 2 °C/min |
| Safety Cutoffs | Auto-stop at +10 °C above expected aniline point or at 170 °C (whichever occurs first) |
| Sample Handling | Modular dual-section test vessel (removable lower section for solid/semi-solid sampling and weighing) |
| Cleaning | In-situ tube cleaning without disassembly |
| Display Interface | Color-coded status indicators (standby / active test / completion) |
| Dimensions | Compact integrated footprint |
| Control System | Embedded microprocessor with repeat-test automation and no sample replacement required between runs |
| Cooling Requirement | External cooling bath or chilled vessel mandatory for ambient temperatures <20 °C |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | AAP-6 |
| Standards Compliance | GB/T 262, JIS K2256, ISO 2977, ASTM D611 |
| Temperature Range | 20°C above ambient to 160°C (extended low-temp operation requires optional chiller system) |
| Control System | Microprocessor-based programmable controller |
| Display | 5.7-inch color LCD, temperature resolution 0.1°C |
| Sensor | PT100 platinum resistance thermometer (100 Ω at 0°C) |
| Detection Method | Infrared LED emitter + phototransistor optical detection circuit |
| Sample Cell | Dual-section U-shaped vacuum-jacketed tube with detachable lower section for weighing |
| Heating Element | Stainless steel micro-heater (20 W) |
| Stirring Mechanism | DC motor-driven impeller via gear-belt coupling |
| Ramp Profile | 10°C/min until 10°C below setpoint, then 2°C/min |
| Safety Protections | Overheat cutoff at setpoint +10°C or 170°C ceiling |
| Data Storage | Auto-log of latest 200 test records (sample ID, result, timestamp) |
| I/O Interfaces | USB, RS-232C, LAN |
| Dimensions | 230 × 470 × 490 mm (W×D×H) |
| Weight | 14 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, 125 W |
| Operating Environment | 10–40°C, ≤90% RH non-condensing |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ABL-8 |
| Test Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523 |
| Temperature Range | −30 °C to +80 °C |
| Ignition System | Dual-mode (Gas Flame & Electric Spark) |
| Repeatability | High |
| Cooling Method | Peltier-based Semiconductor Cooling |
| Display | 5.7-inch Color LCD |
| Data Storage Capacity | 200 Test Records |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor |
| Safety Features | Auto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure |
| Compliance Support | ASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACL-2 |
| Pricing | Upon Request |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACO-100 |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ISO 2592, ASTM D92, IP 36 |
| Ignition Source | Electric or Gas Pilot Flame |
| Temperature Range | Ambient to 400 °C |
| Data Storage Capacity | 200 test records |
| Interface Options | USB, RS-232 |
| Optional Accessories | Thermal Printer, USB Keyboard, USB Flash Drive |
| Security | Password-protected test program |
| Safety Features | Auto-ignition detection, auto-extinguishing system (activated upon flash point confirmation or sustained flame ≥5 s) |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | ACO-8 |
| Test Standards | ASTM D92, ISO 2592, IP 36 |
| Measuring Range | Ambient to 400 °C |
| Heating Power | 800 W Nichrome coil (220–240 V) |
| Temperature Sensor | PT-100 in stainless steel sheath |
| Flash Detection | Dual ionization rings |
| Ignition Source | Automatic gas ignition (LPG or natural gas, ≤10 kPa) |
| Display | 5.7″ color LCD with LED backlight |
| Data Storage | Up to 200 test records |
| Interface | RS-232C ×1, USB ×1 |
| Cooling | Forced-air via sirocco fan |
| Barometric Correction | Built-in sensor, automatic |
| Safety Shutdown | Multi-condition monitoring (EFP+30 °C, sensor fault, thermofuse blow, arm mispositioning, etc.) |
| Dimensions | 230 × 470 × 390 mm (W×D×H) |
| Weight | 16 kg |
| Compliance | Designed for GLP-aligned laboratory environments |
| Brand | Tanaka Scientific Instruments |
|---|---|
| Origin | Japan |
| Model | ACR-6 |
| Heating Power | 1.3 kW |
| Ignition System | Pilot Flame with Manual Lighting of Pilot Tube |
| Cooling Method | Forced Air Cooling via Fan |
| Temperature Monitoring | Thermocouple-Based Flame Detection |
| Control System | Electronic Time Relay |
| Power Supply | 100/220 V AC, 50/60 Hz, 1.4 kW |
| Compliance | ASTM D189, IP 13, GB/T 268 |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACR-6 |
| Pricing | Available Upon Request |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACR-M3 |
| Standards Compliance | ISO 10370, ASTM D4530, GB/T 17144 |
| Gas Flow Control | Auto-switching between 150 mL/min and 600 mL/min |
| Sample Capacity | 6 × large crucibles (5.0 g each) or 12 × small/medium crucibles (0.15–3.0 g each) |
| Heating Temperature | 500 °C ± 2 °C under inert gas atmosphere |
| Residue Weighing Resolution | 0.1 mg (requires external analytical balance) |
| Condensate Collection | Integrated high-temp resistant, explosion-proof condensate bottle |
| Front-panel Float Flowmeter | Visual flow verification and calibration support |
| Automation Level | Fully automated thermal ramping, dwell, cooling, and end-of-test audio alert (10 s) |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | ACR-M3 |
| Standard Compliance | ASTM D4530, GB/T 17144 |
| Heating Range | Ambient to 600 °C |
| Furnace Type | Double-walled stainless steel cylindrical furnace (600 mL capacity) |
| Power Supply | AC 220 V, 50 Hz, 6 A |
| Max. Dual Heater Power | 2 × 500 W |
| Temperature Control | Digital programmable controller (0–500 °C range) |
| Thermocouple | JIS J-type |
| Nitrogen Supply | Primary pressure ≤2058 kPa (21 kgf/cm²), secondary pressure adjustable up to 686 kPa (7 kgf/cm²) |
| N₂ Flow Control | Dual-range automatic switching between 150 mL/min and 600 mL/min via two needle valves + solenoid valve |
| Condensate Collection | Threaded 200 mL borosilicate glass bottle |
| Exhaust | φ12.7 mm stainless steel duct mounted on rear panel |
| Cooling | Axial fan for control unit and furnace lid |
| Dimensions (W×D×H) | 360 × 330 × 350 mm |
| Weight | ~20 kg |
| Sample Throughput | 6 samples (large crucibles) or 12 samples (small crucibles) per run |
| Sample Mass Range | 0.15 ± 0.05 g (for >5% CR), 0.5 ± 0.1 g (for 1–5% CR), 5.0 ± 0.5 g (for <1% CR) |
| [Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | AD-7 |
| Standards Compliance | ASTM D86, ASTM D850, ASTM D1078, GB/T 6536 |
| Temperature Range | 0–450 °C |
| Condenser Temp Control | 0–69.9 °C (Peltier-cooled) |
| Receiving Chamber Temp Control | 10–50 °C |
| Distillation Rate | 2–9 mL/min (PID-controlled, factory-set at 4.5 mL/min) |
| Initial Boiling Point (IBP) Detection | Infrared photoelectric sensor |
| Final Boiling Point (FBP)/Dry Point Detection | Dual-mode (manual visual + optional auto-sensor) |
| Display | 10.4″ color TFT touchscreen |
| Data Storage | 5,000 test records |
| Predefined Methods | 200 user-configurable protocols |
| Interface | RS-232C, Ethernet (TDAS/LIMS), USB |
| Safety Systems | Flame detection sensor, automatic power cutoff, integrated halon-free fire suppression, flask support stop mechanism, sensor fault monitoring, over-temperature interlock] |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AD-7 |
| Temperature Range | 0–450 °C |
| Condenser & Receiving Chamber Cooling | Peltier-based with internal recirculating coolant |
| Temperature Resolution | 0.1 °C |
| Condenser Temp Control Range | 0–69.9 °C (±0.2 °C accuracy) |
| Receiving Chamber Temp Control Range | 0–50 °C (±0.05 °C accuracy) |
| Distillate Rate Control | 2–10 mL/min (PID-regulated, factory default 4.5 mL/min) |
| Initial Boiling Point (IBP) Detection | Infrared photoelectric sensor |
| Dry Point Detection | Manual visual or optional automatic sensor |
| Heating System | 24 V/600 W vortex-type heater with forced-air cooling |
| Safety Systems | Flame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring |
| Data Storage | 5,000 test records |
| Test Method Presets | 200 programmable modes |
| Interfaces | RS-232C, Ethernet (for TDAS/LIMS), USB |
| Display | 10.4″ capacitive touchscreen LCD |
| Atmospheric Pressure Compensation | Automatic or manual input |
| Compliance | ASTM D86, ASTM D850, ASTM D1078, GB/T 6536 |
| Software | TDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper) |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AFP-102 |
| Pricing | Available Upon Request |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AFP-102 |
| Standards Compliance | ASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248 |
| Cooling Method | Integrated Peltier thermoelectric module (no formaldehyde or external chiller required) |
| Temperature Range | Ambient to –60 °C |
| Temperature Resolution | 0.1 °C |
| Cooling Modes | Linear ramp and stepwise (isothermal) cooling |
| Detection Principle | Dual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket |
| Sample Compatibility | Diesel fuels, heating oils, biodiesel blends, and other middle distillates |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | AKV-202 |
| Viscosity Range | 0.75–1,100,000 mm²/s |
| Temperature Bath Range | 20–100 °C (setpoints: 20, 40, 50, 80, 100 °C) |
| Temperature Stability | ±0.01 °C at setpoint |
| Capillary Type | Dual adjustable Ubbelohde-type (Lantz-Stokes design) |
| Detection Method | Filtered photoelectric sensor system |
| Cleaning System | Dual-reservoir solvent/drying agent delivery |
| Printer | Integrated thermal printer |
| Interface | RS-232C (bidirectional data exchange with internal PC and external host) |
| Safety Monitoring | Solvent vapor detection, liquid level sensing, overtemperature protection |
| Dimensions (W×D×H) | 600 × 680 × 680 mm |
| Weight | 75 kg |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | APM-100 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D93, GB/T 261, ISO 2719 |
| Ignition Source | Dual-mode (Gas Flame & Electric Spark) |
| Temperature Range | Ambient to 370 °C |
| Data Storage Capacity | 200 test records |
| Interface | USB (for keyboard, flash drive, and LIMS export) |
| Security | Password-protected test program |
| Safety Features | Integrated thermal cutoff, flame detection interlock, and automatic lid closure |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | APM-8 |
| Standards Compliance | ASTM D93, ISO 2719, GB/T 261 |
| Temperature Range | Ambient to 370 °C |
| Heating Method | Band Heater |
| Cooling | Forced Air |
| Stirring Speed | 100 / 250 rpm (selectable) |
| Temperature Sensor | PT-100 with Stainless Steel Sheath |
| Flash Detection | CRC-type Detector |
| Ignition Sources | Dual Gas (LPG/Natural Gas ≤10 kPa) and Electric (EI-8 Igniter) |
| Atmospheric Pressure Compensation | Integrated Pressure Sensor |
| Display | 5.7″ Color LCD |
| Data Storage | 200 Test Records |
| Interfaces | RS-232C × 1, USB × 1 |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Max Power Consumption | 720 W |
| Energy per Test | ~170 Wh |
| Dimensions | 230 × 470 × 390 mm (W×D×H) |
| Weight | 17 kg |
| Safety Interlocks | Overtemperature (>370 °C or >20 °C above preset FP), Sensor Faults, Fuse Open, Arm Position Error, Stirrer Stall, Microcontroller Failure, Low Backup Battery |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASC-8C |
| Test Method | Closed-Cup Equilibrium Method |
| Operating Mode | Fully Automatic |
| Applicable Standards | ISO 3679, ISO 3680, ASTM D3278, ASTM D7236, IP 534 |
| Temperature Range | −30 °C to +100 °C |
| Ignition Source | Dual-mode (electric spark or gas flame) |
| Repeatability | High |
| Atmospheric Pressure Compensation | Integrated barometric sensor |
| Data Storage Capacity | 200 test records |
| Output Options | Thermal printer, USB export, LIMS integration |
| Security | Password-protected user interface |
| Compliance | Designed for GLP-compliant laboratories and routine QC environments |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASP-6 |
| Measurement Method | Ring-and-Ball (Dual-Sample) |
| Temperature Range | Ambient to 200 °C |
| Display | 5.7-inch LCD, 0.1 °C resolution |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Interface | RS-232C serial port |
| Power Supply | AC 220 V, 50/60 Hz, 12 A |
| Dimensions (W×D×H) | 230 × 440 × 420 mm |
| Weight | Approx. 14 kg |