| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FD |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Capacity | 1–20 positions |
| Sample Volume | 60 µL (50–100 µL typical) |
| Test Time | < 1.5 min per sample |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 5–35°C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Dimensions | 280 × 443 × 434 mm |
| Language Support | English & Chinese |
| Connectivity | RS232, USB, Barcode Scanner Interface |
| Compliance | Designed to support pharmacopeial testing per Chinese Pharmacopoeia (ChP) requirements |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FS |
| Measurement Principle | Freezing Point Depression |
| Temperature Control System | Dual-stage Peltier Cooling |
| Sample Volume | 50–100 µL |
| Calibration | Multi-point, User-defined Calibration Curves |
| Operating System | Android-based Embedded OS |
| Data Storage | Internal SSD with >100,000 Test Record Capacity |
| Compliance Features | Audit Trail, Electronic Signature (21 CFR Part 11 Ready), Role-Based Access Control |
| Connectivity | RS232, USB Host (for keyboard/mouse/scanner), Built-in Thermal Printer |
| Noise Level | <45 dB(A) |
| Pharmacopeia Integration | Preloaded Chinese Pharmacopoeia (ChP) Monographs for >300 Injectable Products |
| Maintenance | Dry-Cooling Architecture (No Heat Transfer Fluid Required) |
| Brand | Tianhe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TH-ZW108 |
| Price | USD 3,650 (approx.) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Max. Heating Rate | 7 °C/s |
| Max. Cooling Rate | 5 °C/s |
| Temp. Uniformity | ≤ ±0.2 °C |
| Temp. Accuracy | ≤ ±0.1 °C |
| Detection Channels | 1 (FAM/SYBR Green I) |
| Excitation Wavelength | 400–700 nm |
| Detection Method | LED excitation + imported photodetector |
| Screen | 7-inch HD capacitive touchscreen |
| Dimensions (L×W×H) | 355 × 200 × 124 mm |
| Weight | 2.5 kg |
| Noise Level | <45 dB |
| Thermal Lid | Auto-pressure-adjusting |
| Data Interface | USB port for import/export |
| Software | Integrated qPCR analysis suite with real-time curve plotting, automatic positive/negative call, GLP-compliant audit trail logging |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | YB-2A |
| Light Source | 20 W tri-phosphor fluorescent lamp with electronic ballast |
| Illuminance Range | 1000–6000 lx |
| Timing Range | 1–79 s (adjustable) |
| Power Consumption | 30 W |
| Digital Illuminance Meter | Integrated, direct-read, stable output |
| Visual Inspection System | Single-sided, operator-optimized optical path with anti-glare and flicker-free illumination |
| Compliance | Designed per Chinese Ministry of Health Standard WB1-362(B-121)-91 for clarity testing of injectables and large-volume parenterals |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | ZRS-8G |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 6 |
| Temperature Range | 5.0 °C (ambient) to 45.0 °C |
| Temperature Accuracy | ≤ ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotational Speed Range | 25–200 rpm |
| Speed Resolution | 1 rpm |
| Speed Stability Error | ≤ ±4% |
| Paddle Wobble Amplitude | ≤ 0.5 mm |
| Basket Wobble Amplitude | ≤ 1.0 mm |
| Shaft-to-Vessel Axis Offset | ≤ 2.0 mm |
| Timer Duration | Up to 99 h 59 min (forward count) |
| Sampling Cycles | Up to 9 programmable cycles |
| Sampling Interval per Cycle | Up to 9 h 59 min (countdown) |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer | TIANLONG |
| Country of Origin | China |
| Model | Biolum |
| Detection Range | 0–999,999 RLU |
| Limit of Detection | 1.0 CFU/mL |
| Detection Sensitivity | 1×10⁻¹⁶ mol ATP |
| Display | 3.5-inch color LCD |
| Dimensions (W×D×H) | 70 × 35 × 189 mm |
| Weight | ≤300 g (with battery) |
| Detection Time | 10 s per sample |
| Accuracy | ±5% or ±5 RLU |
| Data Storage | 999 records |
| Battery Life | >10 h continuous operation, >500 h standby |
| Operating Environment | 5–40 °C, 20–85% RH |
| Connectivity | USB 2.0, Bluetooth 4.0 |
| Power | Rechargeable Li-ion battery (Mini-USB charging), optional solar/car charger |
| Swab Compatibility | TIANLONG ATP QuickSwab (liquid-stable, single-use) |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Biolum Pro |
| Detection Range | 0–999,999 RLU |
| Limit of Detection | 1×10⁻¹⁶ mol ATP (stable detection using ATP standard) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | TY-ATP |
| Detection Range | 0–99,999 RLU |
| Detection Time | 15 s |
| Sensitivity | 1×10⁻¹⁸ mol ATP |
| Display | 3.5-inch capacitive touch LCD |
| Processor | 32-bit high-speed microcontroller |
| Accuracy | ±5 RLU or ±5% |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–85% RH |
| ATP Recovery Rate | 90–110% |
| Detection Modes | RLU, Coliform Screening |
| Auto Pass/Fail Judgment | Yes |
| Data Interface | Mini-USB |
| Power | Rechargeable Li-ion battery (6-month standby at 20 °C) |
| Dimensions (W×H×D) | 188 × 77 × 37 mm |
| Weight | ~280 g |
| Compliance | Designed for ISO 22000, HACCP, and FDA Food Code-aligned hygiene verification workflows |
| Brand | Tianyan |
|---|---|
| Model | TY-BZQ |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | 500 N (optional: 100 N / 500 N / 1000 N) |
| Resolution | 0.01 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Upper Platen Diameter | 10 mm |
| Lower Platen Diameter | 100 mm |
| Parallelism Between Platens | <0.025 mm |
| Dimensions (W×D×H) | 450 × 450 × 680 mm |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz |
| Standard Configuration | Mainframe, Fixture Set, Thermal Microprinter, Touchscreen Control Software |
| Optional | PC with Dedicated Software, Inkjet Printer, Automated Feeding System |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Model | TY-CHY |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Class of Accuracy | Grade 0.5 |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions | 450 × 340 × 390 mm |
| Weight | 30 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 6672-2001, GB/T 451.3-2002, GB/T 6547-1998, ISO 4593:1993, ISO 534:2011, ISO 3034:2011, ASTM D374-1999, ASTM D1777-1996 (2007), JIS K6250-1997, JIS K6783-1994, JIS Z1702-1994, BS 3983-1989, BS 4817, TAPPI T411 |
| Interface | RS232 serial port |
| Optional Accessories | Auto-sampler unit, PC-based analysis software, calibration weights, communication cable |
| Brand | Tianyan |
|---|---|
| Model | TY-FK100 / FK200 / FK300 / FK400 / FK500 |
| Origin | Shandong, China |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power | 500 W |
| Sealing Speed | 10 m/min |
| Sealing Width | 12 mm |
| Temperature Range | 60–220 °C (±1% control accuracy) |
| Sealing Margin Adjustment | 0–35 mm |
| Display | 7-inch color touchscreen (GUI, bilingual Chinese/English, text-to-speech support) |
| Print Capability | Dual-line dot-matrix printing (reversible 180°), customizable font width, selective field suppression, intelligent bag-width matching logic |
| Data Storage | >10 million records |
| Compliance | YY/T 0698.5–2009 (seal strength), YY 0466–2003 (medical device symbols) |
| Enclosure Options | Powder-coated carbon steel or 304 stainless steel |
| Dimensions | 620 × 270 × 220 mm |
| Weight | 20 kg |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-FSX |
| Detection Range | 1 µm – 10 mm |
| Imaging Resolution | 2592 × 1944 (5 MP CMOS camera) |
| Optical Magnification | 100× |
| Image Size Options | 640×480, 1024×768, 2048×1536, 2592×1944 |
| Power Supply | 220 V / 2 A / 50 Hz |
| Compliance | GB/T 6030–2006 |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-GA1. |
| Function Type | Multi-parameter (simultaneous detection of up to 200 food safety analytes) |
| Sample Compatibility | Universal for liquid, extract, and homogenized solid food matrices |
| Detection Time | ≤3 minutes per batch |
| Detection Channels | 12 independent optical channels |
| Display | 10.1-inch vertical capacitive touch LCD (Android OS) |
| Main Controller | ARM Cortex-A7 + RK3288 quad-core CPU (1.88 GHz) |
| Light Source | Imported precision cold LED source with four fixed wavelengths (410 nm, 520 nm, 590 nm, 630 nm) |
| Optical Design | Precision rotating cuvette holder with inter-channel calibration uniformity ≤0.1% |
| Connectivity | Dual-band Wi-Fi (2.4/5 GHz), optional 4G LTE (APN-enabled), Bluetooth 4.2, dual USB 2.0 ports, RJ45 Ethernet |
| Power Supply | AC/DC dual-mode |
| Data Storage | Internal flash ≥16 GB + USB mass storage support |
| Dimensions (L×W×H) | 440 × 300 × 180 mm |
| Compliance | Designed to support ISO/IEC 17025 laboratory practices, aligned with GB 5009.x series, GB/T 5009.x, and SN/T standards for food testing |
| Brand | Tianyan |
|---|---|
| Model | TY-HA01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Height Measurement Range | 0.00–11.00 mm |
| Resolution | 0.01 mm |
| Mass Measurement Range | 0–200 g |
| Mass Resolution | 0.01 g |
| Dimensions (L×W×H) | 400 × 300 × 180 mm |
| Display | Digital LCD |
| Software Integration | Embedded Hough Unit calculation algorithm per USDA AMS standards |
| Brand | Tianyan |
|---|---|
| Model | TY-HRD |
| Origin | Shandong, China |
| Temperature Range | 0–1600 °C (±3 °C accuracy) |
| Resolution | 1 °C (temperature), 1 min (time |
| Heating Rate | 15–20 °C/min up to 900 °C |
| Thermocouple Type | S-type (Platinum-Rhodium/Platinum) |
| Max Control Current | 30 A |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 10 W |
| Dimensions (W×H×D) | 305×390×120 mm |
| Operating Environment | 0–40 °C, RH ≤80% |
| Communication Interface | RS232 |
| Compliance | GB/T 219–2008 (Chinese National Standard for Coal Ash Fusibility) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-L01G |
| Detection Principle | Competitive Inhibition Immunoassay with Colloidal Gold Lateral Flow |
| Sample Throughput | Up to 12 tests per run |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Processor | ARM Cortex-A7 RK3288, quad-core @ 1.88 GHz |
| Power Supply | AC/DC adapter + built-in 6 Ah Li-ion battery (field-deployable) |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Data Storage | >200,000 records (local USB export to Excel) |
| Connectivity | Wi-Fi, RJ45 Ethernet, optional A4 thermal printer interface |
| Compliance Support | FDA 21 CFR Part 11–ready audit trail (user login, permission tiers, calibration lock), GLP/GMP-aligned data management |
| Brand | Tianyan (Shandong) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-NY1 2C |
| Price Range | USD 175 – 1,100 (FOB) |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric Measurement at 410 nm) |
| Number of Channels | 12 |
| Wavelength | 410 nm |
| Inhibition Rate Range | 0–100% |
| Inhibition Rate Accuracy | ≤ ±10% |
| Inhibition Rate Repeatability | ≤ 5% |
| Transmittance Accuracy | ±1.5% |
| Transmittance Repeatability | ≤ 0.5% |
| Absorbance Drift | ≤ 0.005 Abs / 3 min |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Power Supply | DC 12 V (with optional 6 Ah rechargeable Li-ion battery and vehicle adapter) |
| Display | 7-inch capacitive touchscreen (Android OS, ARM Cortex-A7 RK3288 quad-core @ 1.88 GHz) |
| Data Storage | 200,000 test records (exportable as Excel via USB 2.0) |
| Connectivity | Built-in Wi-Fi & wireless upload module |
| Calibration | NIM-certified (National Institute of Metrology, China) |
| Enclosure | Industrial-grade ABS polymer housing |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-SCG |
| Price Range | USD 830–1,810 (FOB) |
| Functionality | Multi-analyte Screening Platform |
| Sample Compatibility | Broad-spectrum aquatic and food matrices |
| Main Control IC | ARM Cortex-A7 |
| Detection Time | ≤ 3 minutes per test |
| Detection Channels | 12 independent lanes |
| Display | 10.1-inch capacitive touchscreen LCD |
| Detection Principle | Colloidal Gold Immunochromatographic Assay (CGIA) |
| Communication Interfaces | USB 2.0, Wi-Fi (802.11 b/g/n), RJ45 Ethernet |
| Power Supply | DC 12 V input (vehicle-compatible), integrated 6 Ah Li-ion battery |
| Data Storage | Internal flash + standard USB port for U-disk export |
| Dimensions (W×D×H) | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Processor | Rockchip RK3288 (Quad-core ARM Cortex-A17, 1.8 GHz) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-SSY-24F |
| Maximum Pressure | 0–24 metric tons (235.2 kN) |
| Piston Diameter | φ95 mm |
| Max Piston Stroke | 30 mm |
| Pressure Display Resolution | 0.01 MPa (equivalent to 0.102 ton-force) |
| Pressure Stability | ≤1 MPa per 10 minutes |
| Worktable Diameter | Φ105 mm |
| Column Spacing | 112 × 160 mm |
| Overall Dimensions | 305 × 200 × 440 mm (L×W×H) |
| Net Weight | 65 kg |
| Protective Shield | Transparent Acrylic |
| Structural Design | Monolithic Mainframe (integrated oil reservoir, baseplate, and chrome-plated cylinder |
| Hydraulic System | Filtered oil circuit, custom piston seal, extended-life tension spring (30 mm stroke retention), aluminum alloy handwheel |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TY-SuperVario-N |
| Speed Range | 600–1130 rpm |
| Temperature Control Range | Ambient to 68 °C |
| Power Supply | 230 V / 50 Hz |
| Internal Chamber Height | 370 mm |
| Overall Height | 460 mm |
| Net Weight | 26 kg |
| Brand | Tianyan |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TY-SYJCT |
| Price | USD 1,380 (FOB) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-SYJCT |
| Price | USD 1,380 (approx.) |
| Display | 10.1" capacitive touchscreen |
| OS | Android-based embedded system |
| Processor | ARM Cortex-A7 RK3288, quad-core @ 1.88 GHz |
| Power Supply | AC/DC dual-mode, 6 Ah Li-ion battery |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Detection Modules | Colloidal gold immunochromatographic assay (CGIA) reader with auto-scanning track, integrated data management & cloud synchronization |
| Data Storage | >200,000 records, USB exportable to Excel |
| Connectivity | Wi-Fi, RJ45 Ethernet, optional A4 thermal printer support |
| Compliance | Designed for alignment with GB/T 22286–2008, GB/T 21312–2007, NY/T 2129–2012, and compatible with national food safety surveillance platforms per SAMR requirements |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-SZT |
| Pricing | Available Upon Request |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-YX432 |
| Price | USD 7,500 (FOB Qingdao) |
| Sample Format | 0.2 mL single tubes & 8-tube strips |
| Thermal Block | Aluminum alloy with Peltier control |
| Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.01 °C (PT1000 sensor) |
| Optical Channels | 4 (Blue/Green/Red/Yellow LEDs) |
| Detection Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 logs |
| Excitation Sources | High-intensity, broad-spectrum, maintenance-free solid-state LEDs |
| Detection System | Imported photomultiplier tube (PMT) |
| Channel Crosstalk | Minimized via precision narrow-band filters + software compensation |
| Software | Cross-platform Windows-compatible |
| Data Export | XLS, CSV, DOCX |
| Reporting | Integrated report generator with audit-ready metadata |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-ZW216 |
| Detection Principle | Real-Time Fluorescent Quantitative PCR (qPCR) |
| Channel Configuration | Dual-channel (FAM/VIC compatible) |
| Sample Capacity | 16 × 0.2 mL wells (supports single tubes & 8-tube strips) |
| Temperature Range | 4–99 °C |
| Thermal Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ≤±0.25 °C |
| Max Heating/Cooling Rate | 6 °C/s / 4 °C/s |
| Optical System | Dual high-intensity LED excitation sources (460–480 nm & 525–545 nm), dual photodiode detectors with narrow-band interference filters |
| Sensitivity | Single-copy DNA detection capability |
| Dynamic Range | 10 orders of magnitude (1–10¹⁰ copies/µL) |
| Linearity | R² ≥ 0.999 |
| Reproducibility | CV < 2% (fluorescence), CV < 2% (sample), CV < 3% (precision) |
| Data Output Formats | PDF, XLS, CSV, DOCX |
| Connectivity | USB 2.0, Wi-Fi (optional), Android-based onboard OS |
| Dimensions | 350 × 384 × 184.5 mm |
| Weight | 5.4 kg |
| Power | 220 V AC, max 300 W |
| Operating Environment | 18–35 °C, 0–85% RH (non-condensing) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-ZXLS |
| Instrument Type | Online |
| Functionality | Multi-parameter (moisture & temperature) |
| Measurement Principle | Resistive |
| Measurable Grains | Corn, Wheat, Soybean, Japonica Rice, Indica Rice, Paddy Rice, Barley, Sorghum, Rapeseed |
| Moisture Range | 11.0–40.0 % w.b. |
| Moisture Resolution | 0.1 % |
| Moisture Accuracy | ±0.5 % (within 10–20 % range) |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1 °C |
| Display | 4.3-inch Chinese-language capacitive touchscreen |
| Operating Ambient | −30 to 100 °C (non-condensing) |
| Power Supply | AC 220 V |
| Host Dimensions | 210 × 260 × 95 mm |
| Sensor Dimensions | 282 × 180 × 160 mm |
| Protection Design | Sealed enclosure for dust and moisture resistance |
| Motor Protection | Overcurrent, open-circuit, and foreign-object (e.g., stone) detection |
| Sampling Cycle | Real-time countdown display |
| Calibration Flexibility | Adjustable roller gap for multi-grain compatibility |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-2002 |
| Quotation | Upon Request |
| Measurement Range | 0–10 mm (customizable beyond standard range) |
| Resolution | 0.01 mm |
| Upper Anvil Diameter | 6 ± 0.05 mm |
| Applied Weights | 130 g, 110 g, and 10 g |
| Probe Tip Diameters | φ2 mm, φ4 mm × 1 mm, φ5 mm, φ10 mm |
| Dimensions (L×W×H) | 145 mm × 195 mm × 80 mm |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-2002 |
| Quotation | Upon Request |
| Measurement Range | 0–10 mm (customizable) |
| Resolution | 0.01 mm |
| Upper Anvil Diameter | 6 ± 0.05 mm |
| Applied Weights | 130 g, 110 g, 10 g |
| Probe Tip Diameters | φ2 mm, φ4 mm × 1 mm, φ5 mm, φ10 mm |
| Dimensions | 145 mm × 195 mm × 80 mm |
| Key | Load between parallel plates: 49 ± 0.05 N (including spring force from dial indicator) |
|---|---|
| Temperature control range | 70 ± 1 °C (adjustable up to 100 °C) |
| Timing range | 0–3 min (digitally programmable) |
| Dial indicator range | 0–30 mm |
| Dial indicator resolution | 0.01 mm |
| Power supply | 220 V, 50 Hz |
| Rated power | 700 W |
| Dimensions (W×D×H) | 360 × 280 × 570 mm |
| Net weight | 35 kg |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TY-2004A |
| Pricing | Upon Request |
| Applied Standard | GB/T 12828 |
| Test Method | Parallel-Plate Compression |
| Applied Load | 49 ± 0.05 N (including spring force from dial indicator) |
| Temperature Control Range | 70 ± 1 °C (adjustable up to 100 °C) |
| Timing Range | 0–3 min (digitally programmable) |
| Dial Indicator Range | 0–30 mm |
| Dial Indicator Resolution | 0.01 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 700 W |
| Dimensions (W×D×H) | 360 × 280 × 570 mm |
| Net Weight | 35 kg |