Industry-specific Instruments
Filter
Showing 5191–5220 of 6141 results
| Brand | TimePower |
|---|---|
| Model | TP5110 |
| Origin | Beijing, China |
| Manufacturer | TimePower |
| Detection Method | Closed-Cup Equilibrium Method (ASTM D3278 / ISO 1523 / ISO 3679 / GB/T 5208) |
| Flash Point Range | −20 °C to +80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Repeatability | ≤2 °C (intra-operator), ≤3 °C (inter-operator) |
| Sample Volume | 2 mL (liquid), 4 mL (semi-solid/solid) |
| Ignition | Electronic spark ignition |
| Cooling | Peltier thermoelectric cooling + optional external chilled water circulation |
| Power Supply | AC 220 V ±10%, 50 Hz ±10%, ≤300 W |
| Operating Environment | 5–30 °C, 30–80% RH |
| Data Storage | 120 test records onboard |
| Display | 8-inch industrial-grade true-color touchscreen (bilingual UI) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP524 |
| Pricing | Upon Request |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Cold Bath Dimensions | Ø210 × 280 mm |
| Temperature Control Range | +20 °C to −70 °C |
| Temperature Stability | ±0.1 °C |
| Bath Agitation | Motor-driven, 6 W, 1200 rpm |
| Refrigeration System | Dual-compressor cascade cooling |
| Sample Stirring | Electromagnetic, 0–120 strokes/min, continuously adjustable |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Total Power Consumption | ≤2000 W |
| Standard Accessories | (1) Dual-compressor refrigerated main unit, (2) Freezing point test tube, (3) Freezing point stirrer assembly, (4) Calibrated thermometer (−80 to +20 °C, ±0.5 °C), (5) Two blind caps, (6) Two 15 A fuses, (7) User manual, (8) Certificate of Conformance |
| Brand | Timepower |
|---|---|
| Model | TP526 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Temperature Control Range | 35 °C to −70 °C |
| Pour Point Range | 5 °C to −70 °C |
| Display | Color LCD Touchscreen (Chinese UI) |
| Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Position | Single-cell configuration |
| Cooling System | Dual-stage compression refrigeration |
| Power Supply | AC 220 V ±10 %, 50 Hz ±10 % |
| Power Consumption | ≤600 W |
| Dimensions (W×D×H) | 500 × 490 × 660 mm |
| Weight | 55 kg |
| Compliance Standards | GB/T 510, GB/T 3535, ASTM D2386, ASTM D97 |
| Brand | TimePower |
|---|---|
| Model | TP526 |
| Temperature Control Range | −70 °C to +35 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Cooling System | High-efficiency compressor-based |
| Heating Capability | Up to 35 °C |
| Sample Tilt Mechanism | Motorized, standards-compliant |
| Test Modes | Standard and accelerated protocols |
| Display | LCD touchscreen interface |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <900 W |
| Dimensions | 460 × 310 × 480 mm |
| Weight | 55 kg |
| Compliance | GB/T 510, GB/T 3535, ASTM D2386, ASTM D97 |
| Brand | Timepower |
|---|---|
| Model | TP526 |
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Equipment Co., Ltd. |
| Temperature Range | Ambient to –70 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Cooling Method | High-efficiency compressor-based refrigeration |
| Heating Capability | Up to 50 °C |
| Display | LCD touchscreen interface |
| Printer | Thermal printer (36-character Chinese/English output) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions | 460 × 310 × 480 mm |
| Weight | 21.3 kg |
| Compliance Standards | GB/T 510, GB/T 3535, ASTM D2386, ASTM D97 |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Co., Ltd. |
| Model | TP526 |
| Measurement Range | Ambient to –70 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Cooling Capacity | –70 °C (compressor-based) |
| Heating Capability | up to 50 °C |
| Display | LCD touchscreen |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions | 460 × 310 × 480 mm |
| Weight | 21.3 kg |
| Compliance | GB/T 510, GB/T 3535, ASTM D2386, ASTM D97 |
| Brand | TimePower |
|---|---|
| Model | TP526 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Test Range | Ambient to –60 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Cooling Method | Thermoelectric (Peltier) |
| Display | LCD |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±10 % |
| Power Consumption | <300 W |
| Dimensions | 475 × 360 × 495 mm |
| Weight | 21.3 kg |
| Environmental Operating Conditions | 10–40 °C, 30–80% RH |
| Brand | Timepower |
|---|---|
| Model | TP526 |
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Co., Ltd. |
| Test Range | Ambient Temperature to –60 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Cooling Method | Semiconductor-based Thermoelectric Cooling |
| Display | LCD |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±10 % |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 475 × 360 × 495 mm |
| Weight | 21.3 kg |
| Operating Environment | 10–40 °C, 30–80% RH |
| Compliance | Designed per GB/T 510–2010 (Petroleum Products—Determination of Pour Point) |
| CPU Architecture | Dual-MCU Control System |
| Self-Diagnostic Function | Yes |
| Brand | TimePower |
|---|---|
| Model | TP526 |
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Category | Petroleum Low-Temperature Property Tester |
| Temperature Range | Ambient to –70 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD Touchscreen |
| Cooling System | High-Efficiency Compressor-Based |
| Heating Capability | Up to 50 °C |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions | 460 × 310 × 480 mm |
| Weight | 21.3 kg |
| Compliance | GB/T 510, GB/T 3535, ASTM D2386, ASTM D97 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP527 |
| Price | Upon Request |
| Temperature Control Range | Room Temperature to 800 °C |
| Temperature Control Accuracy | ±1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Ambient Operating Temperature | 5–35 °C |
| Relative Humidity | <80% RH |
| Power Consumption | 2000 W |
| Dimensions (W×D×H) | 540 × 400 × 400 mm |
| Net Weight | 32 kg |
| Sensor Type | K-type Thermocouple |
| Heating System | Dual-zone (Main + Auxiliary) with Automatic Switching |
| Temperature Uniformity | ≤1 °C across Top/Mid/Bottom zones in Test Flask |
| Observation | Articulated Wide-Angle Mirror Assembly |
| Compliance Standards | DL/T 706–2013, DIN 51794 |
| Brand | TimePower |
|---|---|
| Model | TP527 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Method | Closed-Cup Method |
| Operation Mode | Fully Automatic |
| Applicable Standards | DL/T 706, SH/T 0642, DIN 51794 |
| Repeatability | ≤4 °C |
| Ignition Control | AI-Driven Temperature Regulation Algorithm |
| Temperature Range | 79–400 °C (primary test range), ambient to 400 °C (full heating capability), –25 °C to 200 °C (optional low-temperature configuration) |
| Temperature Uniformity | ≤1 °C across top/middle/bottom of test flask |
| Sensor Type | K-type Thermocouple |
| Display | LED Digital Interface |
| Heating System | Dual Independent Heaters (Primary + Auxiliary) with Auto-Switching Logic |
| Observation | Multi-Axis Adjustable Mirror for Real-Time Flame Detection |
| Brand | Timepower |
|---|---|
| Model | TP532 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Measurement Principle | Potentiometric Endpoint Detection via Laser Photometry |
| Measurement Method | ASTM D664 / GB/T 258–2016 Neutralization Titration |
| Measurement Range | 0.0001–0.9999 mg KOH/g |
| Resolution | 0.0001 mg KOH/g |
| Accuracy | ±0.01 mg KOH/g (for acid number < 0.1 mg KOH/g) |
| Repeatability | 0.02 mg KOH/g (0–0.1), 0.05 mg KOH/g (0.1–0.5), 0.07 mg KOH/g (0.5–1.0), 0.1 mg KOH/g (1.0–2.0) |
| Sample Capacity | 6 positions |
| Power Consumption | ≤60 W (operational), ≤100 W (peak) |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Display | LCD with tactile membrane keypad |
| Printer | Impact dot-matrix printer |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions (W×D×H) | 480 × 340 × 200 mm |
| Net Weight | 12.5 kg |
| Control System | Dual-CPU microprocessor architecture |
| Optical Sensor | Imported low-power laser diode (long-life, stable output) |
| Automation Level | Fully automated extraction, titration, cup rotation, endpoint detection, and reporting |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP532 |
| Measurement Principle | Potentiometric-Optical Endpoint Detection via Laser Photometry |
| Standard Compliance | GB/T 4945–2002 (for insulating oils) |
| Measurement Method | Colorimetric Titration with KOH–Ethanol Standard Solution in Toluene–Isopropanol Extract |
| Detection System | Imported Laser Diode + Photodetector Array |
| Control Architecture | Dual-CPU Microcontroller |
| Automation Level | Fully Automated Extraction, Titration, Cup Rotation, Endpoint Recognition, and Thermal Printing |
| Display | LCD with Icon-Free Touch-Sensitive Keypad |
| Measurement Range | 0.0001–0.9999 mg KOH/g |
| Resolution | 0.0001 mg KOH/g |
| Accuracy | ±0.01 mg KOH/g (for values 0.0001–0.1) |
| Repeatability | 0.02 mg KOH/g (0.0–0.1), 0.05 mg KOH/g (0.0–0.5), 0.07 mg KOH/g (0.5–0.9999) |
| Sample Capacity | 6-position carousel |
| Power Consumption | ≤60 W (operational), ≤100 W (peak) |
| Ambient Operating Conditions | 5–35 °C, ≤80% RH |
| Dimensions (W×D×H) | 480 × 340 × 200 mm |
| Net Weight (main unit) | 12.5 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Brand | TimePower |
|---|---|
| Model | TP532 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Measurement Principle | Potentiometric Titration with Endpoint Detection |
| Measurement Range | 0.0001–0.9999 mg KOH/g |
| Accuracy | ±0.01 mg KOH/g (for acid number 0.001–0.100 mg KOH/g) |
| Repeatability | 0.02 mg KOH/g |
| Resolution | 0.0001 mg KOH/g |
| Sample Capacity | 6 positions |
| Display | 480×272 pixel LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (W×D×H) | 480 × 340 × 200 mm |
| Thermal Printer | Integrated |
| Power Consumption | 60 W |
| Weight | 12.5 kg |
| Brand | Timepower |
|---|---|
| Model | TP532 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Measurement Range | 0.0001–0.4000 mg KOH/g |
| Accuracy | ±0.01 mg KOH/g (for acid number 0.001–0.100 mg KOH/g) |
| Repeatability | 0.02 mg KOH/g |
| Resolution | 0.0001 mg KOH/g |
| Titration Method | Potentiometric Endpoint Detection via Neutralization |
| Sample Capacity | 6 positions |
| Display | TFT LCD (480 × 272 pixels) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (W × D × H) | 465 × 335 × 260 mm |
| Weight | 11.98 kg |
| Power Consumption | 60 W |
| Printer | Thermal printer |
| Brand | Timepower |
|---|---|
| Model | TP532 |
| Measurement Principle | Potentiometric-Optical Endpoint Detection via Colorimetric Titration (KOH-Ethanol Standard Solution) |
| Measurement Range | 0.0001–0.9999 mg KOH/g |
| Resolution | 0.0001 mg KOH/g |
| Accuracy | ±0.01 mg KOH/g (for acid number ≤0.1 mg KOH/g) |
| Repeatability | 0.02 mg KOH/g (0–0.1), 0.05 mg KOH/g (0.1–0.5), 0.07 mg KOH/g (0.5–1.0), 0.1 mg KOH/g (1.0–2.0) |
| Sample Throughput | 6 samples per batch |
| Detection System | Imported low-power laser diode with photodetector array |
| Control Architecture | Dual-CPU microcomputer system |
| Automation Functions | Auto-extraction, auto-titration, auto-cup rotation, endpoint recognition, thermal/impact printing |
| Display | LCD with icon-free tactile keypad |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤100 W (peak), ≤60 W (operational) |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions (W×D×H) | 480 × 340 × 200 mm |
| Net Weight (main unit) | 12.5 kg |
| Compliance | Designed to support ASTM D664, GB/T 258, ISO 661, and IEC 61000-4 electromagnetic compatibility standards |
| Data Output | Integrated dot-matrix printer with timestamped reports |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP5321 |
| Price | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Lab Instrument |
| Model | TP539 |
| Detection Parameter | Mechanical Impurities (by Gravimetric Method per GB/T 511) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature Range | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Overall Power Consumption | ≤1200 W |
| Control Box Dimensions | 390 × 260 × 130 mm |
| Water Bath Dimensions | 90 × 290 × 370 mm |
| Net Weight | 4.8 kg |
| Water Bath Temperature Control Range | Ambient to 90 °C |
| Temperature Control Accuracy | ±1 °C |
| Funnel Temperature Control Range | Ambient to 90 °C |
| Funnel Temperature Display | LED Digital |
| Solvent Compatibility | Toluene (≤80 °C), Ethanol–Toluene Mixture (heated to 60 °C) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP540 |
| Pricing | Available Upon Request |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Power Consumption | <300 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±10% |
| Pump Dimensions | 300 mm × 120 mm × 235 mm |
| Filter Membrane Pore Size | 1.2 µm |
| Filtration Vessel Capacity | 1000 mL |
| Vacuum Source | Adjustable High-Stability Diaphragm Pump |
| Pressure Display Accuracy | High-Resolution Analog/Digital Gauge |
| Brand | Timepower |
|---|---|
| Model | TP547 |
| Type | Kinematic & Apparent Viscosity Tester |
| Compliance | GB/T 6538, ASTM D5293 |
| Temperature Range | −50 °C to +100 °C |
| Temperature Accuracy | ±0.1 °C |
| Bath Control Stability | ±0.05 °C |
| Viscosity Range | 1200–27,000 mPa·s |
| Shear Rate Range | 10⁴–10⁵ s⁻¹ |
| Operating Ambient | −40 °C to +30 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Total Power Consumption | ≤2 kW |
| Heating Power | ≤800 W |
| Refrigeration Range | −50 °C to ambient |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Instruments Co., Ltd. |
| Model | TP547 |
| Compliance | GB/T 6538, ASTM D5293 |
| Temperature Control Accuracy | ±0.05 °C |
| Temperature Range | –50 °C to 100 °C |
| Viscosity Measurement Range | 1200–27000 mPa·s |
| Shear Rate Range | 10⁴–10⁵ s⁻¹ |
| Shear Stress Range | ~1200–27000 mPa·s (apparent) |
| Cooling Range | –50 °C to ambient |
| Heating Power | ≤800 W |
| Total Power Consumption | ≤2 kW |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Temperature Sensor Accuracy | ±0.1 °C |
| Ambient Operating Environment | –40 °C to 30 °C |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TimePower TP553 |
| Pricing | Upon Request |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Compliance | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Display | 128×64 Graphic LCD |
| Resolution | 0.1 µg |
| Measurement Range | 3 µg – 100 mg H₂O |
| Max. Electrolysis Rate | 2.4 mg/min |
| Electrolysis Current | 0–400 mA |
| Stirring Speed | 10 adjustable levels |
| Electrolysis Gain | 10 adjustable levels |
| Data Storage | 256 timestamped records (10-year power-loss retention) |
| Interface | RS232 |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Operating Temperature | 20–30 °C |
| Operating Humidity | ≤85% RH |
| Electrode Fault Detection | Open-circuit & short-circuit auto-diagnosis |
| Sample Compatibility | Liquids (oils, alcohols, solvents), solids (dissolved or homogenized), gases (via carrier gas adapter) |
| Accessories Included | Dual-compartment coulometric cell, 0.5 µL & 50 µL microsyringes, 1 mL glass syringe, vacuum grease, KF electrolyte (pyridine-free formulation available) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Pricing | Available Upon Request |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Compliance Standards | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Display | 128×64 Graphic LCD |
| Resolution | 0.1 µg |
| Detection Range | 3 µg – 100 mg H₂O |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Max. Electrolysis Rate | 2.4 mg/min |
| Electrolysis Current Range | 0–400 mA |
| Stirring Speed Adjustment | 10 steps |
| Electrolysis Gain Adjustment | 10 steps |
| Data Storage | 256 timestamped records with 10-year power-loss retention |
| Interface | RS232 serial port |
| Environmental Operating Conditions | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Electrode Fault Detection | Automatic open-circuit & short-circuit diagnostics |
| Electrolyte Compensation | Blank current compensation & endpoint drift correction |
| Cell Design | Waterproof sealed coulometric electrolytic cell with rapid equilibration |
| Safety Features | On-screen warnings for reagent exhaustion, electrode faults, and out-of-range conditions |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP572 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP572 |
| Voltage Ramp Rates | 2.0 kV/s and 3.0 kV/s (adjustable within 2.0–3.0 kV/s) |
| Measurement Range | 0–80 kV |
| Accuracy | ±2% of full scale |
| Resolution | 0.1 kV |
| Test Repetition | 1–9 cycles (default: 6) |
| Electrode Gap | Standardized per GB/T 507–1986 and DL 429.9–1991 |
| Stirring Mechanism | Magnetic stirrer with programmable agitation duration (0–59 min) |
| Standby Time | 15 min (adjustable 0–59 min) |
| Inter-test Interval | 3–5 min (adjustable 0–9 min) |
| Display | LCD panel with real-time voltage and status feedback |
| Protection | Overvoltage, overcurrent, and automatic zero-return safety interlocks |
| High-Voltage Source | Dry-type transformer assembly with sinusoidal waveform generation and stepless voltage regulation |
| Operating Environment | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions (W×D×H) | 610 × 410 × 425 mm |
| Weight | 45 kg |
| Compliance | GB/T 507–1986, DL 429.9–1991 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP575 |
| Compliance | GB/T 11142–1989, NB/SH/T 0810–2010 |
| Display | 7-inch capacitive touchscreen LCD |
| Temperature Control | 80 °C ±0.05 °C (adjustable range: ambient to 100 °C) |
| Voltage Application | 10 kV ±0.2 kV (50 Hz) |
| Test Duration | 5, 10, 50, or 120 min (automatically selected per standard) |
| Timing Accuracy | <±0.1 s |
| Hydrogen Inlet Pressure | 0.05–0.1 MPa |
| Stirring Speed | 1200 rpm |
| Temperature Resolution | 0.01 °C |
| Voltage Resolution | 0.01 kV |
| Data Storage | 1000 test records |
| Relative Humidity Limit | <85% RH |
| Heating Power | ≤1500 W |
| Total Power Consumption | ≤1700 W |
| Operating Ambient | 10–40 °C |
| Dimensions (Controller / HV Generator / Test Unit) | 320×305×195 mm / 320×305×380 mm / 320×305×590 mm |
| Safety | Integrated interlock switch, earth-grounding requirement, dry-bath protection logic |
| Output | Thermal printer (built-in) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP575 |
| Pricing | Available Upon Request |
| Display | 7-inch capacitive touchscreen LCD |
| Temperature Control Range | Ambient to 100 °C (standard test at 80 °C ± 0.05 °C) |
| Temperature Resolution | 0.01 °C |
| Test Voltage | 10 kV ± 0.2 kV (resolution: 0.01 kV) |
| Frequency | 50 Hz ± 10% |
| Test Duration Options | 5 min, 10 min, 50 min, 120 min (auto-configured per standard) |
| Timing Accuracy | < ±0.1 s |
| Hydrogen Inlet Pressure | 0.05–0.1 MPa |
| Stirring Speed | 1200 rpm |
| Ambient Operating Conditions | 10–40 °C, RH < 85% |
| Heating Power | ≤1500 W |
| Total Power Consumption | ≤1700 W |
| Dimensions (Controller / HV Generator / Test Unit) | 320×305×195 mm / 320×305×380 mm / 320×305×590 mm |
| Data Storage | 1000 test records |
| Safety Features | Grounding terminal, interlocked safety switch, dry-bath protection |
| Output | Thermal printer (integrated) |
| Compliance | GB/T 11142–1989, NB/SH/T 0810–2010 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP575 |
| Quotation | Upon Request |
| Display | 7-inch capacitive touchscreen LCD |
| Temperature Control Range | Ambient to 100 °C |
| Setpoint Accuracy | 80 °C ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Test Voltage | 10 kV ±0.2 kV |
| Voltage Resolution | 0.01 kV |
| Test Duration Options | 5 min, 10 min, 50 min, 120 min (automatically selected per standard) |
| Timing Accuracy | <±0.1 s |
| Hydrogen Inlet Pressure | 0.05–0.1 MPa |
| Stirring Speed | 1200 rpm |
| Heating Power | ≤1500 W |
| Total Power Consumption | ≤1700 W |
| Operating Ambient | 10–40 °C |
| Relative Humidity | <85% RH |
| Data Storage Capacity | 1000 test records |
| Safety Features | Interlocked high-voltage enclosure, earth-grounding requirement, automatic power cutoff on lid opening |
| Printer | Integrated thermal printer |
| Dimensions (Controller / HV Generator / Test Unit) | 320×305×195 mm / 320×305×380 mm / 320×305×590 mm |
| Accessories | Gassing cell, calibrated gas burette |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |