| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm (hydrocarbons other than CH₄) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1 % FS |
| H₂/O₂ | ±2 % FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232, RS-485, (4–20) mA, Ethernet |
| Display | LCD |
| Auto-calibration | Integrated zero-air pump with automatic air-based zeroing |
| Diagnostic Capability | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| CnHm (non-methane hydrocarbons) | (0–10) % vol (optional) |
| Resolution | CO/CO₂/CH₄/CnHm: ±1% FS |
| H₂/O₂ | ±2% FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Auto-calibration | Integrated zero-air pump with automatic air zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| CnHm | (0–10)% (optional) |
| Resolution | CO/CO₂/CH₄/CnHm: ±1% FS |
| H₂/O₂ | ±2% FS |
| Response Time | 15 s (NDIR) |
| Operating Principle | NDIR + Electrochemical Cell (ECD) + Thermal Conductivity Detection (TCD) |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Self-Diagnostic Function | Yes |
| Zero Calibration | Built-in air pump for automatic zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9031EX |
| Product Category | Coke Oven Gas Analyzer |
| Measurement Principle | NDIR + Electrochemical + Thermal Conductivity (TCD) |
| Response Time | 15 s (NDIR channels) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| CₙHₘ (non-methane hydrocarbons) | (0–10)% (optional) |
| Accuracy | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1% FS |
| H₂/O₂ | ±2% FS |
| Resolution | Equivalent to accuracy specification |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232 / RS-485 / (4–20) mA / Ethernet |
| Display | LCD |
| Self-Diagnostic Function | Yes |
| Zero Calibration | Built-in air pump for automatic zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9060 |
| Measurement Range | CH₄: (0–100)% |
| CO₂ | (0–50)% |
| H₂S | (0–9999) ppm |
| O₂ | (0–25)% |
| Resolution | CH₄/CO₂/O₂: 0.01% |
| H₂S | 1 ppm |
| Response Time | T₉₀ ≤ 60 s (NDIR) |
| Principle | NDIR + Electrochemical Detection (ECD) |
| Accuracy | CH₄/CO₂: ±1% FS |
| H₂S/O₂ | ±2% FS |
| Repeatability | CH₄/CO₂: 0.5% FS |
| H₂S/O₂ | 1% FS |
| Optimal Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, dry, oil-free |
| Electrical Interface | RS-485 / RS-232 / 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Enclosure | Stainless steel cabinet with corrosion-resistant components and integrated thermal management |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-9061 |
| Product Type | Biogas Analyzer |
| Measurement Range | CH₄: (0–100)%, CO₂: (0–50)%, H₂S: (0–9999) ppm, O₂: (0–25)% (all ranges selectable) |
| Response Time | T₉₀ ≤ 60 s (NDIR channels) |
| Principle | Non-Dispersive Infrared (NDIR) for CH₄/CO₂/O₂ |
| Flow Measurement | Integrated Ultrasonic Flow Sensor for Sample & Dilution Gas |
| Best Operating Flow | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Sample Requirements | Dust-free, oil-free, and dew-point controlled (achieved via on-board dilution) |
| Electrical Interface | RS-485 / RS-232 serial |
| Power Supply | AC 220 V, 50 Hz |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CuDDI |
| Pricing | Contact for Quote |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GY-1000YPQ |
| Internal Dimensions (W×D×H) | 1450 × 610 × 1180 mm |
| External Dimensions (W×D×H) | 1590 × 830 × 1960 mm |
| Temperature Range | 0–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Range | 30–95 %RH |
| Humidity Fluctuation | ±5 %RH |
| Heating Power | 1800 W |
| Cooling Power | 750 W |
| Fan System | 6 independent circulation fans |
| Refrigeration System | Danfoss compressor with imported electronic expansion valve, pressure relief valve, and defrost valve |
| Humidification | 15 L built-in auto-refill humidifier with dry-run protection |
| Control Interface | 7-inch true-color touchscreen |
| Control Modes | Constant-value and programmable (5 programs × 100 segments each |
| Data Logging | Real-time internal recording + USB export |
| Printer | Integrated thermal printer |
| Security & Compliance | Three-tier user permission system, audit trail compliant with GLP/GMP data integrity requirements |
| Remote Access | Wi-Fi-enabled monitoring and alarm notification |
| Sensor Technology | PT100 temperature sensors + anti-condensation humidity sensors |
| Operation Mode | Balanced heating/cooling and humidification/dehumidification control |
| Power Recovery | Auto-resume function with configurable power-loss memory |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GY-1000YPZ Drug Stability Testing Chamber |
| Price Range | USD 2,800 – 3,500 |
| Capacity | 1000 L |
| Temperature Range | 0–65°C (dark), 10–50°C (with illumination) |
| Humidity Range | 30–95% RH |
| Temperature Uniformity | ±2.0°C |
| Temperature Fluctuation | ≤±0.5°C |
| Humidity Fluctuation | ±5% RH |
| Temperature Resolution | 0.1°C |
| Illumination | None (YP variant) |
| Control Interface | 7-inch full-color touchscreen |
| Programming | 5 user-defined programs, up to 100 segments per program, segment duration up to 999 hours/minutes |
| Data Logging | USB storage support with real-time timestamped recording |
| Refrigeration System | Dual independent hermetic compressors with Danfoss components and electronic expansion valve control |
| Humidity Control | Balanced heating/humidification/dehumidification system |
| Safety | Independent over-temperature cut-off, auto-recovery after power interruption, water shortage protection for humidifier |
| Power Supply | 220 V AC, 50 Hz |
| Operating Ambient | 5–35°C |
| Internal Chamber Dimensions (W×D×H) | 1050 × 600 × 1600 mm |
| Construction | Cold-rolled steel exterior with powder coating |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GY-1000YPZPLUS |
| Internal Dimensions (W×D×H) | 1450 × 610 × 1180 mm |
| External Dimensions (W×D×H) | 1590 × 830 × 1960 mm (excl. door handles, industrial hinges, and humidifier interface) |
| Temperature Control Range (with light) | 10–50 °C |
| Temperature Control Range (dark) | 0–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Range | 30–95 %RH |
| Humidity Fluctuation | ±5 %RH |
| Light Source | 7 pharmaceutical-grade LED illumination panels |
| Illuminance Output | ≥4500 lx ±500 lx |
| Cumulative Illuminance Dose | ≥1.2 × 10⁶ lx·hr |
| Near-UV Energy Dose | ≥200 W·hr/m² |
| Heating Power | 1800 W |
| Refrigeration Power | 750 W |
| Fan Configuration | 6 independent circulation fans |
| Refrigeration System | Danfoss compressor with imported electronic expansion valve, pressure relief valve, and defrost valve |
| Humidification | 15 L built-in auto-refill humidifier with dry-run protection |
| Control Interface | 7-inch true-color touchscreen |
| Control Modes | Constant-value and programmable (5 programs, up to 100 segments per program, segment duration up to 999 hours/minutes) |
| Data Logging | Real-time recording with USB export |
| Network Connectivity | Wi-Fi-enabled remote monitoring and alarm notification |
| Security | Three-tier user permission system with audit trail compliant with ALCOA+ principles |
| Operating Mode | Balanced heating/cooling/humidification/dehumidification via PT100 temperature sensors and anti-condensation humidity sensors |
| Power Recovery | Configurable power-loss memory and auto-resume function |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GY-160YPZ |
| Capacity | 160 L |
| Temperature Range | 0–65°C (dark), 10–50°C (with illumination) |
| Humidity Range | 30–95% RH |
| Temperature Uniformity | ±1.5°C |
| Temperature Fluctuation | ≤±0.5°C |
| Humidity Fluctuation | ±5% RH |
| Temperature Resolution | 0.1°C |
| Illumination | Six-level adjustable LED lighting, ≥10,000 lx (triple-side illumination) |
| Control System | True-color touchscreen controller with programmable logic (5 programs × 30 segments max, 999 h/min per segment) |
| Data Logging | Built-in real-time recording with USB data export (U-disk storage) |
| Refrigeration | Dual independent hermetic compressors with auto-switching logic |
| Humidity Control | 15 L integrated humidifier with auto-fill and dry-run protection |
| Safety | Independent over-temperature cutoff, power-loss memory, automatic recovery on power restoration |
| Compliance Support | Designed to meet ICH Q1A(R2), Q5C stability protocol requirements |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckMate 4 SV |
| Origin | Denmark |
| Gas Measurement | O₂ or O₂ + CO₂ |
| Principle | Zirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂) |
| Sampling Method | Non-invasive optical probe or minimally invasive needle-penetration |
| Minimum Sample Volume | None |
| Resolution | 0.001% |
| Accuracy | ±0.02% |
| Compliance | Designed for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture |
| User Interface | Multi-language capacitive touchscreen (10 languages) |
| Data Management | On-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckPoint 4 |
| Origin | Denmark |
| Detection Gases | O₂ and CO₂ (selectable single or dual) |
| Measurement Principle | Electrochemical (O₂), Infrared (CO₂) |
| Portability | Handheld, battery-powered |
| Interface | Capacitive touchscreen with 10 language options |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned quality control environments |
| Power | Rechargeable Li-ion battery with rugged charging port |
| Accessories | Standard low-cost hypodermic needle probe (22G), optional protective boot |
| Auto-shutdown | Yes, energy-saving mode |
| Gas flow alarm | Visual and audible alert |
| Certifications | CE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines) |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | Lippke 5000 |
| Test Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Volume Capacity | 0–90,000 mL |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Model | MFI-10 |
| Standards Compliance | ISO 1133, ASTM D1238 (Methods A & B) |
| Measurement Outputs | Melt Flow Index (MFI), Melt Flow Rate (MFR), Melt Volume Rate (MVR), Melt Density/Viscosity Derivation |
| Configurable Test Methods | Up to 10 user-defined test protocols |
| Optional Accessories | Automatic timer, motorized weight loading system, automatic specimen cutter, corrosion-resistant barrel assembly, displacement sensor |
| Display | Backlit LCD with step-by-step guided operation and audible prompts |
| Software Integration | NEXYGEN Data Analysis Software (optional) |
| System Architecture | Modular, field-upgradable platform supporting manual or fully automated operation |
| Brand | DAYUAN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DY-6400 |
| Price Range | USD 0.15–1,500 (FOB) |
| Brand | DAYUAN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-PCD |
| Price Range | USD 1,400 – 7,000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) with Disposable Screen-Printed Electrodes (SPEs) |
| Target Analytes | Pb²⁺, Cd²⁺ |
| Analysis Time | ≤4 min per sample (electrochemical step) |
| Operating System | Android-based embedded OS |
| Processor | Allwinner A83T Octa-Core ARM Cortex-A7 @ 2.0 GHz |
| Internal Storage | 16 GB eMMC (expandable to 64 GB via microSD) |
| Display | Capacitive color touchscreen |
| Connectivity | USB 2.0, 10/100 Mbps Ethernet, HDMI output, Bluetooth 4.2, Wi-Fi 802.11 b/g/n |
| Printing | Integrated thermal printer + external printer support via USB or network |
| Data Capacity | ≥100,000 test records with timestamp, operator ID, and calibration metadata |
| Power Supply | 5 V DC adapter + built-in rechargeable Li-ion battery |
| Max Power Consumption | 10 W |
| Compliance | Designed to support GLP-compliant data integrity |
| Brand | dc-energies |
|---|---|
| Model | DC980 |
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Quotation | Upon Request |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem-380 |
| Sample Capacity | 119 positions |
| Reagent Positions | 49 (with refrigerated storage) |
| Optical Cell | 64-position quartz cuvette carousel, 1 cm pathlength |
| Throughput | up to 350 samples/hour |
| Dilution Range | 1–100× in-cuvette dilution |
| Cleaning | 8-step ultrasonic cuvette washing station with optical validation |
| Detection Principle | Photometric colorimetry (absorbance measurement at defined wavelengths) |
| Software | Dual-language (English/Chinese), compliant with GLP data integrity requirements |
| Waste Management | Sealed waste sensing and containment system |
| Compliance | Methods aligned with China National Tobacco Industry Standards (e.g., YC/T series) |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Anna |
| Detection Principle | Automated Segmented Flow Analysis (SFA) with Photometric Detection |
| Sample Throughput | Up to 200 samples/hour |
| Sample Capacity | 49 positions |
| Reagent Positions | 31 (with optional refrigerated storage) |
| Optical Cell | 64-position quartz cuvette carousel, 1 cm path length, reusable |
| Cleaning | 8-step ultrasonic washing station with optical validation |
| Dilution Capability | On-board 1 mL dilutor, up to 100× automatic dilution in cuvette |
| Blank Correction | True sample blank and reagent blank compensation |
| Waste Management | Sealed waste sensing & collection system |
| Software | Dual-language (English/Chinese), compliant with GLP audit trail requirements |
| Regulatory Alignment | Methods validated per China National Tobacco Industry Standards (e.g., YC/T 247–2008, YC/T 160–2002, YC/T 173–2003) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECOFOG |
| Pricing | Upon Request |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A-1190 |
| Price Range | USD 4,200 – 7,000 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Compliant Standards | GB/T 261-2008, GB/T 21615-2008, ASTM D93 |
| Repeatability | ≤2 °C |
| Ignition Method | Electronic spark ignition and adjustable gas flame |
| Temperature Range | 10–40 °C (ambient operating), 0–350 °C (test range) |
| Resolution | 0.1 °C |
| Data Storage | 120 test records onboard |
| Interface | RS-232 & RS-485 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Relative Humidity | <85% RH |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | A1017 |
| Measurement Range | 10–2,000,000 mPa·s |
| Rotor Set | Four standard spindles (No. 1–4) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm (stepped, not continuously variable) |
| Accuracy | ±1% of full scale (F.S.) |
| Display | Backlit high-contrast LCD showing viscosity, spindle number, rotational speed, sample temperature, % torque, and maximum measurable viscosity at selected speed |
| Data Output | RS232 serial interface for PC connectivity |
| Printing | Integrated thermal or impact dot-matrix printer support (via parallel/RS232) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Optional DC Input | 12 V / 1 A adapter |
| Operating Environment | 5–45 °C, ≤85% RH |
| Net Weight | 16 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Delite A1018 |
| Price | USD 13,800 (FOB Beijing) |
| Viscosity Range | 1000–1,000,000 mPa·s |
| Temperature Control Range (Bath) | −60 °C to +25 °C |
| Sample Temp Accuracy | ±0.1 °C |
| Bath Temp Stability | ±0.1 °C |
| Rotational Speeds | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Included Rotors | LV-1, LV-2, LV-3, LV-4 (4 total) |
| Power Supply | AC 220 V ±10%, ≤1500 W |
| Interface | RS-232C, PT100 temperature probe port |
| Cooling Method | Imported hermetic compressor |
| Calibration | Certified reference oils (ASTM D2983, ISO 3104 compliant) |
| Dimensions | 480 × 580 × 610 mm |
| Weight | 85 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable Instrument |
| Model | A1030 |
| Detection Target | Particulate Contaminants in Hydraulic & Lubricating Oils |
| Microscope Magnification | 100× |
| Particle Size Range | 5–150 µm |
| Cleanliness Rating Scales | NAS 1638 (Classes 00–12) and ISO 4406:2021 (Codes 1–24) |
| Filter Membrane Pore Sizes | 1.2 µm and 5 µm |
| Compliance Standard | DL/T 432–1992 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A1065 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Stirring Speed | 1500 rpm |
| Sample Capacity | 8 test tubes |
| Stirring Timer Range | 1–59 min |
| Sample Equilibration Timer | 1–59 min |
| Stirrer Shaft Pre-heat Timer | 1–59 min |
| Arm Dwell Time | 1–59 min |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤2000 W |
| Dimensions (W×D×H) | 572 mm × 335 mm × 791 mm |
| Net Weight | 38 kg |
| Compliance Standards | GB/T 7305, GB/T 7605 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | A1104 |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Control Range | RT+10 °C to 300 °C (minimum setpoint 50 °C) |
| Temperature Stability | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Rated Power | 1220 W |
| Test Stations | 4 glass vials |
| Rotation Speed | 5 rpm |
| Interior Chamber Dimensions | 425 × 400 × 345 mm |
| Overall Dimensions | 705 × 580 × 530 mm |
| Applicable Standards | SH/T 0301, ASTM D2619 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | A1121 |
| Price Range | USD 7,000 – 14,000 |
| Measurement Range | Ambient to –70 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD Touchscreen |
| Printer | Thermal, 36-character Chinese/English output |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 460 × 310 × 480 mm |
| Weight | 21.3 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A1261 |
| Heating Method | Electric Furnace |
| Heating Power | 300 W + 600 W + 1000 W (Triple-Zone) |
| Temperature Control Range | 0–520 °C |
| Temperature Control Accuracy | ±5 °C |
| Total Power Consumption | ≤2000 W |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85 % RH |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Dimensions (W×D×H) | 345 × 345 × 381 mm |
| Net Weight | 22 kg |
| Compliance Standard | SH/T 0170 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A1460 |
| Product Category | Laboratory Instrument |
| Test Parameter | High-Temperature High-Shear Viscosity (HTHS) |
| Applicable Standards | SH/T 0703, ASTM D5481 |
| Power Supply | 220 V, 50 Hz |
| Temperature Control Method | Aluminum Block Bath |
| Test Temperature | 150 ± 0.1 °C |
| Capillary Inner Diameter | 0.15 mm |
| Capillary Effective Length | 16–18 mm |
| Gas Pressure Range | 0.5–3.5 MPa |
| Number of Capillary Cells | 1 |
| Detection Principle | Pressure-Driven Capillary Flow under Controlled Thermal and Shear Conditions |
| Automation | Fully Automated Timing, Pressure Stabilization Monitoring, HTHS Viscosity Calculation & Reporting |