| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Type | Ion-Selective Electrode (ISE) Analyzer for Sodium (Na⁺) |
| Measurement Principle | Standard Addition Method with Solid-State Sodium ISE |
| Compliance | Designed to support compliance with GB 28050–2011, FDA 21 CFR Part 11 (when used with validated EasyDirect™ configuration), ISO/IEC 17025 laboratory practices |
| Software | EasyDirect™ Data Acquisition Software |
| Brand | Astori |
|---|---|
| Origin | Italy |
| Model | CryoTouch 1 |
| Display | 7-inch full-color touchscreen |
| Sample Volume | 2–2.5 mL |
| Analysis Time | ~2 min |
| Preheating Time | ~5 min |
| Temperature Range (Ambient) | +5°C to +36°C |
| Resolution | ±0.0005 °C |
| Repeatability (Raw Milk) | ±0.0025 °C |
| Output Units | °C, °H, % Water |
| Data Storage Capacity | >4,000 results |
| Interface | USB, RS-232 |
| Optional | EP-50 thermal printer |
| Dimensions (W×D×H) | 29 × 44 × 33 cm |
| Weight | ~13 kg |
| Power Supply | 220 V / 50 Hz / 150 W |
| Compliance | IDF-ISO 5764:2009, AFNOR, GB 5413.38–2010 |
| Certification | Verified by China National Institute of Metrology |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSCQY-3000 |
| Measurement Principle | Coulometric-Gravimetric Method |
| H Range | 0–20 wt% |
| C Range | 1–99 wt% |
| Sample Mass | 70–75 mg (air-dried, <0.2 mm) |
| Analysis Time | ~10–15 min (including isothermal holds at 300°C for 30 s, 500°C for 2 min, and 850°C for ~10 min) |
| Electrolysis Voltage | Coating: 10 V |
| Operational | 24 V |
| Electrolysis Current | >600 mA (initial), <70 mA (endpoint) |
| Accuracy | Complies with GB/T 15460–2003 (H: ±0.15 wt%, C: ±0.50 wt%) |
| Heating Rate | ~50 min to 850°C |
| Linearity & Stability | ±0.1% full scale |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSCQY-5000 |
| Measurement Principle | Coulometric–Gravimetric Method |
| Carbon Range | 1–99 wt% |
| Hydrogen Range | 1–20 wt% |
| Furnace Temp. | 850 °C ±10 °C (combustion), 400 °C ±10 °C (reduction) |
| Electrolysis Voltage | 24 V (main), 10 V (coating film) |
| Electrolysis Current | >500 mA (working), <70 mA (endpoint) |
| Test Duration | 9–13.5 min |
| Linearity of Coulometric Integrator | ±0.1% |
| Max. Permissible Error | H ≤0.15 wt%, C ≤0.50 wt% |
| Sample Particle Size | <0.2 mm |
| Heating Rate | 25–30 °C/min |
| Power Supply | 220 V ±10%, 50 Hz, 3 kW |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MiniLab EL |
| Application | Elemental Analysis of Lubricating Oils |
| Instrument Type | Benchtop/Field-Deployable Laboratory Analyzer |
| Compliance | Designed for ASTM D6595, ASTM D5185, ISO 8217, SAE J183, MIL-STD-3007 |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-24521 |
| Compliance | GB/T 24521–2009 |
| Sample Chamber Internal Diameter | 16.3 ± 0.05 mm |
| Compaction Mass | 6 kg (main weight), 1 kg (auxiliary weight) |
| Standard Steel Column Diameter | Φ16.3 ± 0.03 mm |
| Sieve Apertures | 0.315 mm and 0.500 mm (100 mm diameter × 50 mm height) |
| Particle Size Ranges | 0.315–0.500 mm (Φ2.5 mm sieve), 0.500–1.000 mm (Φ4 mm sieve) |
| Leveling Sensitivity | 1 mm/m (200 mm spirit level) |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-2801C-1 |
| Penetration Range | 0–700 dmm |
| Temperature Control Range | 0–65 °C |
| Temperature Stability | ±0.1 °C at 25 °C |
| Penetration Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Standard Needle | 50 mm length, 2.5 g ±0.05 g |
| Standard Cone | 102.5 g ±0.05 g |
| Timing Options | 5, 8, 10, 12, 30, 60 s (±0.1 s tolerance) |
| Bath Type | Rigid borosilicate glass cylinder with magnetic stirrer |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤300 W |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0595 |
| Measurement Range | 0–650 Penetration Units (0.1 mm) |
| Minimum Readout | 0.1 Penetration Unit |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 Penetration Unit |
| Timing Options | 5 s, 8 s, 10 s, 12 s, 30 s, 60 s (timing error < ±0.1 s) |
| Standard Cone Mass | 102.5 ± 0.05 g |
| Power Supply | AC 220 ± 10% V, 50 Hz, ≤300 W |
| Dimensions | 280 × 350 × 700 mm (L×W×H) |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0983 |
| Penetration Measurement Range | 0–700 dmm |
| Temperature Control Range | 0–65 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Penetration Resolution | 0.01 mm |
| Maximum Penetration Depth | ±1 dmm |
| Standard Cone (No. 1) | (102.5 ± 0.05) g |
| Cone Rod Mass | (47.5 ± 0.05) g |
| Timing Options | 5, 8, 10, 12, 30, 60 s (±0.1 s accuracy) |
| Power Supply | AC 220 V ±10 %, 50 Hz, ≤300 W |
| Dimensions (L×W×H) | 280 × 350 × 700 mm |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0983H |
| Penetration Range | 0–650 dmm |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Control Range | 0.00–50.00 °C |
| Temperature Stability | ±0.1 °C |
| Timing Range | 0–250 s |
| Timing Accuracy | ±0.1 s |
| LVDT Displacement Sensor Range | 0–66 mm |
| Displacement Resolution | 0.01 mm |
| Cone Mass (Type I) | 102.5 ± 0.05 g |
| Cone Rod Mass | 47.5 ± 0.05 g |
| Power Supply | 220 ± 10% VAC / 50 Hz |
| Net Weight | 12.5 kg |
| Dimensions (L×W×H) | 390 × 310 × 575 mm |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-154E |
| Penetration Range | 0–650 Penetration Units (0.1 mm per unit) |
| Minimum Readout | 0.1 Penetration Unit |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 Penetration Unit |
| Temperature Control Range | 0.00–50.00 °C (with ±0.1 °C stability) |
| Timing Accuracy | ±0.1 s (0–250 s programmable) |
| Displacement Sensor | Laser-based, 0–66 mm range, ±0.1 mm repeatability |
| Cone Assembly Mass | 37.5 g ±0.05 g (cone: 22.5 g ±0.025 g |
| rod | 15 g ±0.05 g) |
| Test Fixture | 200 mm diameter solid hemispherical PET support (Shore A hardness: 75–85) |
| Data Storage | 200 test records |
| Communication | RS-485 (MODBUS RTU), USB export |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-2102H |
| Measurement Range | 5–80 °C (water bath) / 32–162 °C (glycerol bath) |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 1.0–1.5 °C/min |
| Sample Capacity | 2 specimens simultaneously |
| Bath Vessel Dimensions | Ø110 mm × 130 mm H |
| Stirring | Adjustable magnetic stirrer |
| Data Storage | 200 test records (.csv export via USB) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Max. Power Consumption | 800 W |
| Net Weight | 12.0 kg |
| Dimensions (L×W×H) | 390 mm × 300 mm × 575 mm |
| Compliance | Chinese Pharmacopoeia 2020 Edition, General Chapter 2102 |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-22459D |
| Penetration Range | 0–650 dmm (0.1 mm increments) |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Control Range | 0.00–50.00 °C (±0.1 °C stability) |
| Timing Range | 0–250 s (±0.1 s accuracy) |
| LVDT Displacement Sensor | 0–66 mm range, ≤±0.1 mm repeatability |
| Standard Cone Assembly | Total mass 102.5 g ±0.05 g, cone rod mass 47.5 g ±0.05 g (conforms to GB/T 22459.1–2008) |
| Data Storage | 200 test records |
| Communication | RS-485 (MODBUS RTU), USB data export |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions | 390 × 310 × 575 mm (L×W×H) |
| Net Weight | 12.5 kg |
| Brand | MITONG |
|---|---|
| Model | SYP-476A |
| Origin | Shanghai, China |
| Measurement Range (H) | 0–20 wt% |
| Measurement Range (C) | 0–100 wt% |
| Combustion Furnace Temp | 850 °C ±3 °C |
| Conversion Furnace Temp | 350 °C ±3 °C |
| Temperature Control Accuracy | ±1 °C |
| H-Determination Time | 10 min |
| C-Determination Time | 15 min |
| Electrolytic Cell Dimensions | 250 mm length × 5 mm ID × 8 mm OD |
| Electrolysis Voltage (Coating) | 10 V |
| Operating Voltage | 24 V |
| Max Electrolysis Current | 600 mA |
| Endpoint Current | ≤65 mA |
| Heating Rate | 25–30 °C/min |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power | 3 kW |
| Heating Element | Ni-Cr Resistance Wire |
| Temperature Sensor | K-Type Thermocouple |
| Sample Size | ≤0.2 mm (80 mesh) |
| Sample Capacity | 1 per run |
| Compliance | GB/T 476–2008 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W 3/38 H |
| Application | PV Backsheet & Encapsulant Barrier Testing |
| Compliance | ASTM F1249 |
| Detection Range | 0.05–200 g/(m²·day) |
| Sensor Type | Patented Modulated Infrared Detector |
| Chamber Configuration | Dual removable test cells (4 samples per run) |
| Control System | Fully automated temperature, RH, and carrier gas flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Measurement Principle | Modulated IR detection of water vapor in carrier gas stream |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/38 H |
| Detection Limit | 0.05 g/(m²·day) |
| Measurement Range | 0.05–200 g/(m²·day) |
| Test Chambers | 4 independent horizontal dual-membrane chambers |
| Compliance | ASTM F1249 |
| Sensor Type | Modulated Infrared (Patented MOCON) |
| Environmental Control | Automated temperature, RH, and N₂ flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Software Interface | Local PC GUI or optional touchscreen HMI |
| Test Mode Options | QC pass/fail mode, reference film validation, triplicate testing |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/40 |
| Detection Limit | 0.000025 g/(pkg·day) |
| Test Chambers | 4 independent |
| Temperature Range | 10–50 °C |
| RH Range | 30–90 % RH |
| Sensor Type | Modulated Infrared (ASTM F1249 compliant) |
| Automation | Fully automated T/RH/flow control, motorized test cartridge exchange, integrated conditioning & purge |
| Interface | Touchscreen HMI with real-time parameter monitoring |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | AQUATRAN® Model 3 |
| Test Range (Film) | 0.00005–5 g/m²·day |
| Test Range (Container) | 0.00000025–0.025 g/pkg·day |
| Resolution | 0.00001 g/m²·day |
| Repeatability | ±0.00005 g/m²·day |
| Temperature Range | 5–50 °C (±0.2 °C at 100% RH) |
| Humidity Range (Detector Gas) | 5–90% RH & 100% RH |
| (Carrier Gas) | Dry |
| Test Chamber Options | Dual 50 cm² chambers |
| Compliance | ASTM F3299, ISO 15106-3, GB/T 21529-2008, YBB00092003-2015 |
| Brand | MOCON / Dansensor |
|---|---|
| Origin | Denmark |
| Model | CheckMate 4 |
| Measurement Gases | O₂ only or O₂ + CO₂ dual-sensor configuration |
| Detection Principle | Electrochemical (O₂) and Infrared (CO₂) |
| Sample Volume Required | < 2 mL |
| Data Storage Capacity | Up to 1,000,000 test records |
| User Profiles | Configurable individual logins with role-based access |
| Interface | 7-inch capacitive multi-touch LCD (English, Spanish, French, German, Chinese, Portuguese, Russian) |
| Connectivity | Ethernet (LAN), USB 2.0 (for barcode scanner, keyboard, printer, or data export via USB drive) |
| Sensor Module Design | Field-replaceable, pre-calibrated modular sensors |
| Compliance | Designed to support GLP/GMP environments |
| Calibration | Factory-calibrated |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor ISM-3 |
| Measurement Range | 1 ppm – 100 % O₂ (std. 0–20.9 %) |
| Accuracy | ±1% of reading |
| Sensor Type | Ceramic Solid-State Electrochemical |
| Response Time | <60 s (t₉₀) |
| Flow Rate | 125 mL/min |
| Warm-up Time | 10 min (operational), 20 min (full stabilization) |
| Calibration Interval | 12 months |
| Output Signal | 4–20 mA (standard), optional 0–10 V |
| Alarm Outputs | 2 programmable O₂ alarms + system fault alarm (max. 48 V, 1 A, SPST configurable) |
| Power Supply | 230 VAC ±10% / 115 VAC ±10%, 50–60 Hz |
| Enclosure Material | Stainless steel (IP65-rated housing) |
| Dimensions (H×W×D) | 125 × 185 × 125 mm (ISM-3i), 125 × 185 × 160 mm (ISM-3x w/ integrated display) |
| Weight | 3.7 kg (ISM-3i), 3.8 kg (ISM-3x) |
| Brand | Mocon |
|---|---|
| Model | Dansensor LeakMatic II |
| Origin | Denmark |
| Type | Online Non-Destructive CO₂-Based Leak Detection System for Modified Atmosphere Packaging (MAP) |
| Max. Test Speed | 4 cartons/min |
| Max. Package Dimensions (with fill) | 330 × 610 × 300 mm (L×W×H) |
| Sensor Type | Optical CO₂ Sensor |
| Test Pressure Range | Down to 300 mbar absolute |
| Warm-up Time | 1 min (cold start), 20 sec (from standby) |
| Number of Programmable Test Methods | 16 |
| Interface | Dual RS232 ports, Relay outputs (≤48 V/1 A) |
| Power Supply | 400 VAC |
| Weight | ~450 kg |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | LeakPointer 3 |
| Detection Limit | 50 µm |
| Test Cycle Time | 10 s per package |
| Max. Chamber Vacuum | –750 mbar |
| CO₂ Sensor Type | NDIR |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 100–260 VAC, 50/60 Hz |
| Dimensions (open lid) | 617 mm H × 543 mm W × 400 mm D |
| Weight | 20 kg |
| Data Storage Capacity | >1,000,000 test records |
| Compliance | CE-marked |
| Recommended CO₂ Ambient Level | <1500 ppm |
| Calibration Interval | Every 12 months |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | Lippke 5000 |
| Origin | Denmark |
| Application | Medical, Pharmaceutical & Food Packaging Seal Integrity Testing |
| Test Principles | Pressure Decay, Burst, Creep, Bubble, and Combined Testing |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Max Test Volume | 90 L |
| Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Power | 90–264 VAC, 47–63 Hz, ≤50 W |
| Dimensions | 284 × 236.5 × 185 mm |
| Weight | 3.4 kg |
| IP Rating | IP20 |
| Operating Temp | +2 °C to +25 °C |
| Humidity | 10–90% RH (non-condensing) |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor MAP Check 3 |
| Price Range | USD 6,800 – 13,600 |
| Oxygen Sensor Type | Electrochemical, Range: 0–100% O₂, Accuracy: ±0.01% abs (≤1% O₂), ±1% rel (>1% O₂) |
| CO₂ Sensor Type | Heated Dual-Beam NDIR, Range: 0–100% CO₂, Accuracy: ±0.5% abs, ±1.5% rel |
| Warm-up Time | 10 min (O₂), 8 min (CO₂) |
| Gas Flow Rate | 6–500 L/min |
| Inlet Pressure | 2–10 bar |
| Pressure Drop | 1 bar @ 10 bar inlet |
| Communication Interfaces | 2× RS232C, LAN 10/100 Mbit (Modbus TCP), USB, 4–20 mA / 0–10 V analog outputs, 24 VDC logic I/O |
| Power Supply | 103–132 / 207–264 VAC, auto-ranging, 47–63 Hz |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 8.5–11.5 kg |
| Enclosure Rating (optional) | IP45 (NEMA 3S) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Model | MAP Mix 9001 ME |
| Gas Channels | 2 or 3 |
| Flow Range | 20–400 L/min (40–850 SCFH) |
| Max Output Pressure | 6 bar |
| Input Pressure Range | 5.5–10 bar (varies by configuration) |
| Accuracy | ±2% (at 15–100% flow, 10–90% blend ratio) |
| Housing Material | Stainless Steel |
| Compliance | CE-marked |
| Dimensions (D×H×W) | 420 × 194 × 235 mm |
| Weight | 10–12 kg |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAP Mix Provectus |
| Price Range | USD 13,500 – 27,000 |
| Gas Types Supported | O₂, N₂, CO₂, Air, Ar (optional) |
| Mixing Configurations | 2-gas or 3-gas |
| Max Total Output Flow | 1500 L/min (3-gas mode) |
| Flow Accuracy | ±2% at ≥50 L/min |
| Input Pressure Range | 2–10 bar |
| Pressure Drop | ≤1 bar at 10 bar inlet |
| Flow Control Range per Gas | 6–500 L/min |
| Operating Temperature | 0–50 °C |
| Display | Touchscreen LCD |
| Connectivity | RS232 ×2, Ethernet (10/100 Mbit, Modbus TCP), USB, 24 VDC I/O |
| Power Supply | 103–132 / 207–264 VAC, 47–63 Hz or 24 VDC |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 12.0–14.0 kg |
| IP Rating (with optional kit) | IP45 (NEMA 3S) |
| Compliance | CE-marked |
| Predefined Programs | Up to 10 standard gas mixtures |
| Data Logging | Timestamped flow, pressure, mixture ratio, runtime, total consumption |
| Integration | Fully compatible with Dansensor MAP Check 3 gas analyzers |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiCheck 2 |
| Price Range | USD 13,500 – 27,000 |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optech-O2 P |
| Power Supply | USB-powered (2.5 W) |
| Operating Temperature | 5–40 °C (Headspace Mode), 10–35 °C (Dissolved O₂ Mode) |
| Measurement Principle | Fluorescence-based Confocal Optical Sensing |
| Detection Range (Headspace) | 0.050%–25% O₂ (500 ppm–250,000 ppm) |
| Detection Range (ImPULSE™ Adhesive Sensor) | 0.001%–25% O₂ (10 ppm–250,000 ppm) |
| Repeatability (Needle Probe, 0–150 mmHg) | ±0.100% O₂ or ±5% of reading (whichever is greater) |
| Repeatability (Needle Probe, 150–1000 mmHg) | ±0.015% O₂ or ±2% of reading (whichever is greater) |
| Repeatability (ImPULSE™ Sensor) | ±0.015% O₂ or ±3% of reading (whichever is greater) |
| Probe Dimensions (w/ Needle) | 4.83 × 3.30 × 15.24 cm (H×W×D) |
| Probe Dimensions (w/o Needle) | 4.83 × 3.30 × 22.86 cm (H×W×D) |
| Preheat Time | 20 min |
| Compliance | CE, CSA, UL certified |
| Pressure Compensation | Integrated for needle-based measurements |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 H |
| Detection Principle | Coulometric Sensor (ASTM D3985) |
| Compliance | ASTM D3985, ISO 18369-4:2017, GB/T 11417.7–2012 |
| Sensor Type | Absolute, Zero-Calibration Coulometric Sensor |
| Measurement Range | Ultra-Low to High OTR (O₂) |
| Application Focus | Rigid Gas Permeable (RGP) & Soft Hydrogel/Silicone Hydrogel Contact Lens Materials |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 |
| Detection Principle | Coulometric (COULOX®) Sensor-Based OTR Measurement |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 Ready (with optional software package) |
| Test Chamber | Horizontal, Interchangeable Sealed Test Cell with TruSeal® Dual-Gasket Design |
| Sample Handling | Manual single-sample loading per cycle |
| Typical OTR Range | 0.005–10,000 cm³/m²·day·atm (dependent on cell configuration and film barrier level) |
| Sensor Type | Absolute coulometric oxygen sensor (zero-calibration required) |
| Data Output | Real-time OTR curve, permeation onset time, steady-state slope calculation |