Industry-specific Instruments
Filter
Showing 1291–1320 of 2171 results
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | B121 |
| Price | USD 1,200 (FOB Beijing) |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Measurement Principle | Guarded Three-Electrode Ring Method |
| Resistance Range | 1.0×10³ – 2.0×10¹² Ω |
| Resistivity Range | 1.0×10³ – 2.0×10¹² Ω·m |
| Sheet Resistance Range | 1.0×10⁴ – 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ – 0.1×10¹² Ω (auto-ranging) |
| Power Supply | 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 × 90 × 275 mm |
| Net Weight | ≤3.0 kg |
| Standard Electrode | Triple-ring coaxial electrode (center cylinder Ø50 mm × 40 mm h |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWR |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Heating Power | 2.5 kW |
| Heating Medium | Methyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt, 20 L required) |
| Sample Stands | Three independent test stations per bath |
| Deformation Measurement | Linear encoder-based dial indicator (resolution 0.001 mm, accuracy ±0.01 mm) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Heating Rates | 120 ±5 °C/h (12 ±1 °C/6 min) or 50 ±3 °C/h (5 ±0.5 °C/6 min) |
| Deformation Range | −0.1 to 5.0 mm |
| Cooling Method | Natural convection above 150 °C |
| Maximum Settable Temperature | 300 °C with over-temperature cut-off |
| Load Rod + Indenter Mass | 88 g |
| Standard Loads | Vicat GA = 10.0 N ±0.2 N (1000 g), GB = 50.0 N ±1.0 N (5000 g) |
| HDT fiber stress options | 0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C) |
| Compliance | ASTM D1525, ASTM D648, ISO 306:2004, ISO 75-1:2013, GB/T 1633–2000, GB/T 1634.1–2004, GB 8802 |
| Brand | Nosaka |
|---|---|
| Origin | Japan |
| Model | EKITEN-Read |
| Capsule Sizes | #00, #0, #1, #2, #3, #4 |
| Production Rate | 500–2,500 capsules/hour |
| Fill Volume Range | 0.075–0.85 mL |
| Fill Temperature Control | Ambient to 75 °C |
| Power Supply | 200 V, 3-phase, 50/60 Hz, 15 A |
| Compressed Air Requirement | 0.5 MPa |
| Dimensions (W×D×H) | 1,450 × 715 × 1,470 mm |
| Weight | 600 kg |
| Sealing Method | Heat-activated polymer tape seal |
| Drying Method | Filtered ambient-air convection (non-thermal) |
| Orientation Correction | Force-free quadrisectional alignment |
| Vacuum-Assisted Capping | Integrated vacuum-decompression system for bubble-free cap-body junction |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | 10012006 |
| Operating Temperature Range | −80 °C to +100 °C |
| Sample Capacity | 5 specimens (ASTM D1329) or 10 specimens (ISO R 974) |
| Cooling Options | Dual-coil test bath with compatibility for liquid nitrogen, external cryogenic chiller, or dry-ice-based regulation |
| Bath Volume | 25 L |
| Integrated Dual-Stage Compressor System | Yes (−80 °C capability) |
| Compliance Standards | ASTM D1329, ISO R 974, TR-Test method |
| Safety Features | Automatic pendulum release mechanism, guarded sample positioning, mechanical interlock for operator protection |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | HDT/VICAT |
| Maximum Temperature | 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤0.2 °C |
| Temperature Stability (Oil Bath Fluctuation) | ±0.2 °C |
| Heating Rates | 50 °C/hr, 120 °C/hr, or Custom |
| Displacement Resolution | 0.001 mm |
| Displacement Accuracy | <0.01 mm |
| Sample Immersion Depth | ≥35 mm |
| Span Between Supports (HDT) | 100 mm (optional 64 mm) |
| Sample Length (HDT) | Up to 102 mm |
| Test Stations | 6 independent positions |
| Weight Load Range | 1–2048 g (binary HDT weights), plus 10 N and 50 N VICAT needles |
| Cooling System | Integrated stainless-steel water-jacketed oil bath with external 18 °C coolant |
| Safety Features | Nitrogen purge interface, physical barrier (mesh screen) between heating/stirring components and sample zone, dual stirrers and heater isolated from test chamber |
| Compliance | ASTM D648, ASTM D1525, ISO 75-1/2/3, ISO 306, GB/T 1634, GB/T 1633, DIN 53461 |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | TearATS-200 |
| Maximum Force | 100 N |
| Force Resolution | 0.1 mN |
| Accuracy | ±1% of full scale |
| Measurement Units | mN, N |
| Display | 7-inch color touchscreen interface |
| Data Output | USB 2.0, RS-232 |
| Sample Clamping System | Integrated notch-and-grip fixture |
| Pendulum System | Triple-mass calibrated pendulum with motorized lift mechanism |
| Calibration | Built-in calibration control system |
| Data Storage | Up to 20 test results with parameter tagging |
| Compliance | ASTM D1922, ASTM D1938, ISO 6383-1, ISO 6383-2, TAPPI T414, GB/T 455 |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabMaster-aw neo |
| Measurement Range | 0.0300–1.000 aw |
| Accuracy | ±0.0001 aw |
| Temperature Control Range | 0–60 °C |
| Temperature Stability | ±0.01 °C |
| Display | 240 × 480 LCD |
| Dimensions | 260 × 440 × 220 mm |
| Weight | 9.8 kg |
| Power Supply | 90–260 V, 50/60 Hz, max. 65 W |
| Protection Rating | IP21 |
| Interface | RS-232, USB, D-Sub 9M/9F |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabMaster-aw neo |
| Measurement Range | 0.0300–1.000 aw |
| Temperature Control Range | 0–60 °C |
| Temperature Stability | ±0.01 °C |
| Display | 240 × 480 LCD |
| Interface | RS-232, USB, D-Sub 9M/9F |
| Dimensions | 260 × 440 × 220 mm |
| Weight | 9.8 kg |
| Power Supply | 90–260 VAC, 50/60 Hz, max. 65 W |
| Protection Class | IP21 |
| Sensor Technology | NOVALYTE® Electrolytic Conductivity Sensor (Contactless, Maintenance-Free) |
| Calibration Standards | Factory-supplied saturated salt solutions (4–100% RH equivalent) |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabStart-aw |
| Instrument Type | Portable |
| Measurement Range | 0.030–1.000 aw |
| Accuracy | ±0.01 aw |
| Temperature Range | 15–30 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Backlit LCD (shows aw, temperature, RH%) |
| Weight | 1 kg |
| Sample Cup Capacity | 20 reusable cups included |
| Calibration Standard | Non-consumable, multi-year service life |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabStart-aw |
| Measurement Range | 0.030–1.000 aw |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Sensor Type | CM-4 Capacitive Electrolyte Sensor |
| Temperature Control | None (ambient measurement only) |
| Temperature Range for Measurement | 15–30 °C |
| Temperature Accuracy | ±0.3 K |
| Resolution | 0.01 aw |
| Accuracy | ±0.03 aw |
| Display | Backlit LCD (aw, °C, %RH) |
| Sample Cups | 20 reusable stainless-steel cups included |
| Data Storage | None (real-time readout only) |
| Power Supply | 90–264 VAC, 50–60 Hz |
| Dimensions (H×W×D) | 85 × 140 × 225 mm |
| Weight | 1.2 kg |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabSwift-aw |
| Instrument Type | Portable |
| Measurement Range | 0.03–1.000 a<sub>w</sub> |
| Accuracy | ±0.001 a<sub>w</sub> |
| Temperature Operating Range | 5–45 °C |
| Host Weight | 1.2 kg |
| Calibration | Factory-performed 6-point calibration |
| Data Storage | Integrated SD card |
| Display | Large LCD |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabSwift-aw |
| Measurement Range | 0.03–1.000 aw |
| Resolution | 0.01 aw |
| Accuracy | ±0.01 aw |
| Temperature Range | 5–45 °C |
| Temperature Accuracy | ±0.15 K |
| Weight | 1.2 kg |
| Data Storage | SD card |
| Calibration | Factory 6-point certified calibration |
| Sensor Type | CM-2 dual-electrolyte resistive sensor |
| Compliance | NIST-traceable, FDA-recommended, ISO 21807 compliant |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Temperature Control Range | 15–30 °C |
| Accuracy | ±0.001 aw |
| Temperature Accuracy | ±0.1 °C |
| Display | Full-color TFT touchscreen |
| Probe Type | Patented Resistive Electrolyte Sensor (REMS) |
| Standard Reference | Long-life saturated salt solution standards |
| Host Weight | 1 kg |
| Compliance | NIST-traceable calibration, FDA-recognized methodology, ISO 21807, AOAC 975.34, USP <1112> |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Operating Temperature | 5–45 °C |
| Temperature Control Range | 15–30 °C |
| Temperature Accuracy | ±0.15 K |
| Water Activity Resolution | 0.01 aw |
| Water Activity Accuracy | ±0.005 aw |
| Display | Large LCD touch screen |
| Data Storage | Internal memory for test data and methods |
| Connectivity | SD card, RS-232, USB |
| Dimensions (H×W×D) | 105 × 200 × 300 mm |
| Weight | 2.8 kg |
| Brand | NORMALAB |
|---|---|
| Origin | France |
| Model | NTB Classic |
| Temperature Range | Ambient to 250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.02 °C |
| Temperature Display Resolution | 0.1 °C |
| Controller Precision | 0.01 °C |
| Test Positions | 6–9 |
| Compliance | ASTM D130, ASTM D4048, ISO 2160, IP 154, DIN 51759, NF M 07-015, GB/T 5096, SH/T 0023 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HY-760BX |
| Pricing | Upon Request |
| Control System | PLC-based Touchscreen Interface |
| Test Stations | 12 independent channels |
| Max. Sample Capacity | 12 specimens (standard configuration) |
| Specimen Type | Dumbbell-shaped or square cross-section rubber/plastic strips |
| Clamping Method | Four-sided mechanical clamping |
| Stroke Adjustment Range | 0–100 mm (continuously adjustable) |
| Test Speed | 60–300 rpm ±10 rpm |
| Drive Mechanism | Motor-driven eccentric cam + precision linkage system with linear guide columns |
| Failure Detection | Real-time individual channel break detection with autonomous counter halt |
| Safety Features | Interlocked transparent safety guard enclosure |
| Compliance Standards | GB/T 1688–2021, ISO 6943:1985, ASTM D430–18, DIN 53509-1:2006 |
| Brand | OASIS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LZ-7000 |
| Detection Method | Combined Spectrophotometric and Dry-Chemistry Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 36 |
| Measurement Error | ≤5% |
| Limit of Detection (LOD) | 0.01 mg/kg |
| Display | Color capacitive touchscreen |
| Storage | MicroSD (TF) card expandable |
| Connectivity | Wi-Fi, Bluetooth, Ethernet |
| Interfaces | USB 2.0, RJ45 Ethernet, HDMI |
| Power Supply | DC 12 V (adapter included) |
| Battery | Built-in high-capacity rechargeable Li-ion battery |
| Processor | Multi-core 1.8 GHz ARM-based SoC |
| Data Output | Integrated thermal printer + external printer support |
| GPS | Built-in GNSS module for geotagging |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA FIM |
| Detection Principle | High-Resolution Flow Imaging Microscopy (HiRes-FIM) |
| Particle Size Range | 0.2 µm – 2 mm |
| Camera Options | 12 MP monochrome or color, high-frame-rate sensor |
| Auto-focus | Real-time autofocus without focus beads |
| Magnification Switching | Tool-free, RFID-recognized modular objectives |
| Compliance | USP <788>, USP <789>, Ph. Eur. 2.9.19, ISO 14644-1, FDA 21 CFR Part 11, GLP/GMP-ready |
| Software | SMILLA View v5.x with audit trail, electronic signatures, LIMS integration via ASTM E1384 / LADS framework |
| Cleaning | Fully automated post-run rinse and backflush cycle |
| Pump Configurations | MACRO (peristaltic), MICRO1 (single syringe), MICRO2 (dual alternating syringe), HYBRID (peristaltic + syringe) |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 122-90 |
| Pricing | Upon Request |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 127-40 |
| Pricing | Upon Request |
| Design | Floor-Standing |
| Standard Bit | 1.0″ dia × 6″ length |
| Optional Bits | 0.5″, 0.75″, 1.5″ dia × 6″ length |
| Cooling System | Integrated Water-Cooling with Rotating Swivel Coupling & Shut-Off Valve |
| Splash Guard | Included |
| Accessories | Drain Pan, 6″ Adjustable Clamp, Cooling Hose |
| Dimensions (W×D×H) | 41 cm × 76 cm × 170 cm |
| Weight | 106.6 kg |
| Power Requirement | 220 V, 50/60 Hz |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Model | 171-04 / 171-192-1 |
| Max Temperature | 260 °C |
| Max Pressure | 2000 psi (standard tank) / 5000 psi (threaded tank) |
| Sample Volume | 500 mL |
| Heating Power | 800 W (four 200 W heaters) |
| Power Supply | 115–220 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 25.4 × 45.7 × 106.7 cm |
| Weight | 24.1 kg |
| Pressure Source | Nitrogen (≥10.343 MPa / 1500 psi supply) |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Model | 170-01-3 / 170-01-2 / 170-181-1-N etc. |
| Max Temp | 204°C |
| Max Pressure | 1500 / 2000 / 5000 psi |
| Sample Volume | 175 mL |
| Heating Power | 400 W |
| Dimensions | 19.1 × 27.9 × 59.7 cm |
| Weight | 12.3 kg |
| Voltage | 220 V |
| Pressure Source | N₂ or CO₂ Cartridge |
| Certifications | ASME BPVC Section VIII compliant vessel design, traceable serial-numbered test cells with material and pressure certification |
| Key | Brand: OFITE |
|---|---|
| Origin | USA |
| Model | 120-285-230-DAS |
| Maximum Load Capacity | 40,000 lbf (178 kN) |
| Maximum Pressure | 10,000 psi (based on 4 in² surface area of 2″ cement cube) |
| Adjustable Loading Rate | 250–40,000 lbf/min (in 250 lbf/min increments) |
| Minimum Load Threshold | 1,000 lbf |
| Minimum Pressure | 250 psi |
| Dimensions (W×D×H) | 23″ × 23″ × 26.5″ (58 × 58 × 67 cm) |
| Weight | 102 kg |
| Power Supply | 230 V, 50 Hz |
| Compliance | API RP 10B-2 (Cement), API RP 19C (Proppant) |
| Safety Features | Interlocked safety guard, burst disc, overpressure alarm, self-aligning platens |
| Control Interface | Windows-based software with RS-232 and Ethernet connectivity |
| Sample Types | Cylindrical and cubic cement specimens |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 152-16-1 |
| Price | Upon Request |
| Motor Power | 1 HP |
| Max Speed | 10,000 rpm |
| Speed Control | Continuously Variable |
| Sample Volume Range | 1 mL to 12 L |
| Flow Rate | 20 L/min |
| Display | Digital Tachometer, Programmable Integral Timer, Real-Time Current Monitoring |
| Interface | Touchscreen Control Panel |
| Dimensions (W×D×H) | 94 × 31 × 51 cm |
| Weight | 25 kg |
| Voltage | 220 V |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 113-00 |
| Price | Upon Request |
| Power Supply | 220 V |
| Pneumatic Supply | 60–100 PSI |
| Sample Chamber Capacity | 350 mL |
| Mud Density Range | 0.83–18.0 lb/gal |
| Maximum Torque | 100 lbf·in |
| Torque Accuracy | ±0.1% of Full Scale |
| Maximum Lateral Load | 60 lbf |
| Maximum Rotational Speed | 200 rpm |
| Circulation Pump Speed | 20–500 rpm |
| Calibration Reference (Water) | μ = 0.32–0.36 |
| Test Cell Material | Acrylic |
| Rotating Shaft Material | AISI 4140 Steel, 37 HRC |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 120-70-1 |
| Quotation | Upon Request |
| Max Pressure | 13.8 MPa |
| Max Temperature | 232.2 °C |
| Temperature Control Accuracy | ±1.0 °C (digital PID) |
| Sample Cup Rotation Speed | 200 rpm |
| Sample Volume | 500 mL |
| Filtrate Collection Time | 30 min |
| Filtrate Volume Reporting Unit | cm³ (cc) |
| Power Supply | 220 V, 50 Hz, 10 A |
| Cooling Water Requirement | 40 PSI |
| Nitrogen Supply Range | 13.8–17.2 MPa |
| Dimensions (packed) | 97 × 66 × 86 cm |
| Weight (packed) | 99.8 kg |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 122-186-101 |
| Pricing | Upon Request |
| Max Pressure | 3,000 psi (20.7 MPa) |
| Max Temperature | 400 °F (204.4 °C) |
| Height | 10 in (25 cm) |
| Diameter | 2.75 in (7 cm) |
| Weight | 13.5 lb (6.3 kg) |
| Component Set | #122-186-001 (Cylinder Body), #122-186-002 (Split Brass Insert), #122-186-003 (End Cap), #122-186-010 (O-Ring), #122-186-501 (Handle) |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 127-00 |
| Pricing | Upon Request |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 127-68-1 |
| Pricing | Upon Request |
| Motor | Leeson, 1/3 HP, 5.8 A, 1725 RPM |
| Arbor Size | 5/8" |
| Blade Capacity | 8"–10" |
| Manual Cutting Depth | 3" |
| Powered Feed Cutting Depth | 2-5/8" |
| Max Jaw Opening | 3-1/4" |
| Table Dimensions | 15-3/8" × 19-1/2" (391 × 495 mm) |
| Overall Dimensions | 27" × 17" × 19" (686 × 432 × 483 mm) |
| Net Weight | 70 lb (31.8 kg) |
| Shipping Weight | 80 lb |
| Voltage/Frequency | 230 V, 50 Hz |
| Blade Spec | 10" × 0.040" × 5/8" bore, sintered diamond-impregnated |
| Feed Rate | 3/16" per minute (single-speed powered feed) |
| Construction | Cast aluminum housing, worktable, blade guard, and power feed enclosure |
| Safety Shield | PETG high-impact copolymer |
| Bearing Assembly | Sealed arbor-bearing unit |
| Clutch Mechanism | Brass friction clutch plate |
| Base Material | 1/2" polypropylene |
| Vise System | Vertical rock vise with 360° rotation capability in manual mode |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Model | 130 |
| Max Pressure | 16,000 psi (110.3 MPa) |
| Max Temperature | 400 °F (204.4 °C) |
| Temperature Control | Digital PID with ±1 °F resolution |
| Heating Power | 2500 W (optional 5000 W) |
| Mixer Speed | 150 rpm |
| Chamber Material | 316 Stainless Steel |
| Power Supply | 220 V, 50/60 Hz, 25 A |
| Dimensions | 25 × 16 × 20 in (63.5 × 40.6 × 50.8 cm) |
| Weight | 215 lb (97.6 kg) |
| Air/N₂ Supply Required | 100–150 psi (690–1035 kPa) |
| Cooling Water Supply Required | 40 psi (276 kPa) |
| Compliance | API RP 10B-2 (ISO 10426-2) |