| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Model | TOMs-F (T/PE) |
| Flow Rate | 46 L/min |
| Operating Temperature | 40–65 °C |
| Viscosity Range | 0–220 cSt (@ 40 °C) |
| Compatible Fluids | Mineral Oils, Synthetic Lubricants, Fire-Resistant Hydraulic Fluids (e.g., Phosphate Esters) |
| Power Supply | 480 V AC, 3 HP, 3-Phase (Optional) |
| Particle Removal Efficiency | β ≥ 1000 (at rated particle size) |
| Water Removal | Free & Dissolved Water via Membrane + Dry Nitrogen Purge |
| Acid Number Reduction | Yes, via Ion-Exchange Media |
| Optional Condition Monitoring | Particle Count, Water Content, Viscosity, Colorimetry, Temperature |
| Brand | Sonnen |
|---|---|
| Model | F22 |
| Application | Crude Fiber, Neutral Detergent Fiber (NDF), Acid Detergent Fiber (ADF), Acid Detergent Lignin (ADL), and Insoluble Dietary Fiber analysis |
| Principle | Standardized acid-base digestion (AOAC 978.10, AOAC 2002.04, ISO 13906, GB/T 6434–2022) |
| Filtration Technology | 25 µm pore-size filter bags (optional 15 µm or 10 µm) |
| Batch Capacity | 30 samples per run |
| Temperature Range | Ambient to 100 °C |
| Sample Mass per Bag | 0.1–5.0 g |
| Repeatability | ≤0.5% RSD |
| Temperature Control Accuracy | ±0.1 °C |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (W×D×H) | 373 × 500 × 450 mm |
| Weight | 25 kg |
| Safety | High-pressure sealed digestion chamber, no cooling water required, no glass components, operational in standard lab environment without fume hood |
| Brand | SOOHOW INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Model | DR100 |
| Power Supply | 220 VAC ±10%, 50 Hz (with 12 VDC/5 A adapter) |
| Sample Volume | 1 mL per analysis |
| Analysis Time | <10 min |
| Magnetic Field Gradient | >5.0 T/cm |
| Maximum Magnetic Flux Density | >1.5 T |
| Resolution | 0.1 (unitless reading scale) |
| Input Interface | Auto-sampling |
| Display | High-sensitivity capacitive touch screen |
| OS | Windows 7 |
| USB Ports | 4 × USB 2.0 |
| Network Interface | RJ45 Ethernet |
| Cleaning Solvent | Tetrachloroethylene (C₂Cl₄) |
| Brand | SOPTOP |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | SOPTOP Optics Co., Ltd. |
| Type | Domestic Industrial Vision Inspection System |
| Model | MINIRZJ-300 |
| Power Supply | AC 220 V |
| Total Power Consumption | 5000 W |
| Compressed Air Requirement | 0.5 MPa |
| Overall Dimensions (L×W×H) | 2000 × 1300 × 2100 mm |
| Weight | 1600 kg |
| X/Y/Z Transport Axis Repeatability | ±0.02 mm |
| Sorting Y/Z Axis Repeatability | ±0.02 mm / ±0.03 mm |
| Feeding & Detection Z/X Axis Repeatability | ±0.03 mm / ±0.02 mm |
| Field of View | 21 mm × 21 mm |
| Miss Detection Rate | <1% (typical) |
| Overkill Rate | <10% (typical) |
| UPH | ≥7000 (for ≤8×8 mm components, 10×10 tray, ≥80% pass rate) / ≥4000 (for ≥12×12 mm components, 7×7 tray, ≥80% pass rate) |
| Defect Localization Accuracy | ±2.1 µm (point), ±0.1° (angle) |
| Compatible Carrier Sizes | 115×115 mm, 115×135 mm, 101.5×101.5 mm |
| Supported Component Types | Square, round-threaded, screen-printed, dual-camera IR cut filter assemblies |
| Minimum Component Footprint | 4.5×4.5 mm |
| Detection Principle | Grayscale-based optical contrast analysis using high-resolution CCD imaging |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | AT Xtend |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 6–8 |
| Temperature Range | 30–40 °C |
| Rotational Speed Accuracy | ±1 rpm |
| Regulatory Compliance | 21 CFR Part 11–compliant software control |
| Applicable USP Methods | USP <711> (Apparatus 1, 2, 5, 6) |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | CE 7smart |
| Instrument Type | Online Dissolution Tester |
| Number of Dissolution Cells | 7 |
| Temperature Range | 20–45 °C (deviation < ±0.1 °C) |
| Temperature Accuracy | ±0.1 °C |
| Water Bath Temperature Resolution | ±0.2 °C |
| Water Bath Volume | 8 L |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | DT2 |
| Number of Disintegration Baskets | 2 |
| Bath Volume | 5.5 L |
| Temperature Range | 20–60 °C |
| Stroke Frequency | 30 ± 1 cycles/min |
| Detection Principle | Conductivity-based tablet contact sensing with USP-compliant stainless steel mesh |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | ST50 |
| Compliance | 21 CFR Part 11, USP <1217>, EP 2.9.8 |
| Measurement Range | 0–300 N (adjustable) |
| Force Resolution | 0.1 N |
| Positioning Accuracy | ±0.05 mm |
| Sample Handling | Up to 5 physical parameters per cycle (hardness, weight, thickness, diameter/length, width) |
| Data Output | CSV, PDF, XML |
| Safety | ESD-Safe Enclosure |
| Interface | 7-inch capacitive touchscreen with graphical workflow navigation |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-910A |
| Pricing | Available Upon Request |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-DR1505A |
| Pressure Mode | Vacuum (Reduced-Pressure) |
| Temperature Range (Distillation) | Ambient to 400 °C |
| Cold Bath Temperature Range | 5–80 °C |
| Compliance | ASTM D1160, ASTM D2892, ASTM D5236, ISO 3405, GB/T 6536 (Vacuum Mode Adaptation), IP 123 |
| Brand | -- |
|---|---|
| Origin | Japan |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | IPCE |
| Quotation | Upon Request |
| Measurement Mode | AC |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FDM 6000 |
| Type | Portable Instrument |
| Detection Principle | Surface Acoustic Wave (SAW) Sensor Technology |
| Measurement Range | 0.2–15% fuel dilution (v/v) |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 seconds per sample |
| Sample Volume | <1 mL |
| Power Source | Rechargeable lithium-ion battery |
| Data Storage | Up to 3 calibration curves |
| Display | Color touchscreen interface |
| Compliance | Designed for ASTM D7943-22 and ISO 4406-aligned maintenance practices |
| Software Guidance | Multilingual audio-assisted operation (including English voice prompts) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FDM 6000 |
| Instrument Type | Portable Analyzer |
| Detection Parameter | Fuel Dilution in Engine Oil |
| Measurement Principle | Surface Acoustic Wave (SAW) Sensor Analysis of Head-Space Vapor |
| Detection Range | 0.2–15% v/v Fuel Dilution |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 seconds per sample |
| Sample Volume Required | <1 mL |
| Power Source | Rechargeable Lithium-Ion Battery |
| Data Storage | Up to 3 Calibration Curves |
| Interface | Color Touchscreen with Audio Guidance (Multilingual, including English) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FDM 6000 Series |
| Product Type | Portable Instrument |
| Detection Parameter | Fuel Dilution in Engine Oil |
| Detection Principle | Surface Acoustic Wave (SAW) Sensor + Headspace Vapor Analysis per Henry’s Law |
| Detection Range | 0.2–15% v/v |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 s |
| Sample Volume | <1 mL |
| Power Supply | Rechargeable Li-ion Battery |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −30–85 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Weight | >3 kg |
| Dimensions | 17 × 20 × 13 cm |
| Environmental Rating | IP34, NEMA Enclosure |
| Shock & Vibration Compliance | MIL-STD-810G |
| Electrical Safety Certifications | FCC Class B, CE |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FDM Vial Kit (Qty 50) |
| Package | 50 vials per kit |
| Part Number | 346162035 |
| Application | Fuel dilution analysis in lubricating oil samples |
| Compliance | Designed for use with ASTM D3524, D7897, and ISO 3104-compliant instrumentation |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Product Type | Imported |
| Model | FDM Vial Kit (Qty 50) |
| Pricing | Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FerroCheck 2000 |
| Price | Upon Request |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −30–85 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Weight | >3 kg |
| Dimensions | 17 cm × 20 cm × 13 cm |
| Shock & Vibration Certification | MIL-STD-810G |
| Electrical Safety | FCC Class B, CE |
| Environmental Rating | NEMA 3R, IP34 |
| Sample Type | In-service lubricating oils and hydraulic fluids |
| Measurement Principle | Magnetic susceptibility-based ferrous particle quantification |
| Response Time | ≤30 seconds per sample |
| Detectable Ferrous Particle Size Range | ~1 µm to >1 mm |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FerroCheck 2000 |
| Type | Portable Instrument |
| Compliance | ASTM D8120 |
| Detection Principle | Magnetic Susceptibility-Based Impedance Measurement |
| Sample Volume | 1.5 mL (oil), 0.75 mL (grease) |
| Analysis Time | ≤30 s |
| Detection Limit | <3 ppm Fe |
| Repeatability | ±2% RSD |
| Power | Rechargeable Li-ion battery (4 h runtime) |
| Data Output | CSV, AMS OilView-compatible |
| Calibration | Pre-loaded with certified calibration standards |
| Temperature Compensation | Automatic real-time coil current balancing |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | FieldLab 58 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58 |
| Product Type | Portable Instrument |
| Detection Capabilities | Elemental Analysis (XRF), Particle Counting, Kinematic Viscosity at 40 °C, FTIR-based Oxidation, Nitration, Soot, Water, TAN/TBN, Fuel & Glycol Contamination |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 487.68 × 386.08 × 228.6 mm (L × W × H) |
| Compliance | ASTM D6595, D7690, D7883, D7621, D7943, ISO 11171, ISO 4406, ISO 21468, ISO 21469, USP <1058>, FDA 21 CFR Part 11 (audit trail enabled in software) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Instrument Type | Portable Infrared Spectrometer |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Detection Targets | Water, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Contamination Index |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference oils |
| Lubricant Compatibility | Mineral & synthetic engine oils, gear oils, turbine oils, hydraulic fluids, transmission fluids, greases, biodiesel, and fuel blends |
| Cleaning Method | Solvent-free |
| Measurement Principle | Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectroscopy |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Product Type | Portable Instrument |
| Detection Principle | Direct Reading Infrared (DIR) Spectroscopy |
| Compliance | ASTM D7889, ASTM E2412, ASTM D4739, ASTM D664, ASTM E1655 |
| Key Parameters | TAN (mg KOH/g), TBN (mg KOH/g), Oxidation (Abs/0.1 mm), Nitration (Abs/mm²), Sulfation (Abs/mm²), Water (ppm), Glycol (%), Soot (%), FAME (%), Residual Carbon, Additive Depletion, Fuel Dilution, Oil Mismatch Index, FFA (%), Total Glycerin, Antioxidant Content (%) |
| Sample Volume | 1–2 drops |
| Measurement Time | ~60 seconds |
| Power | Rechargeable Li-ion battery (≥6 h operation) |
| Dimensions | 240 × 140 × 70 mm |
| Weight | 1.4 kg |
| Software | FluidScan Manager (PC-based, with trend analysis, asset management, automated reporting, audit trail, and data synchronization) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluidScan 1000 Series |
| Instrument Type | Portable Analyzer |
| Measurement Parameters | Water Content, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Overall Oil Health Index |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference spectra (mineral & synthetic oils, greases, biodiesel, fuels) |
| Cleaning Method | Solvent-free |
| Detection Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Portability | Handheld, battery-operated, field-deployable |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluidScan |
| Product Type | Portable Instrument |
| Detection Parameters | Contaminants, Oxidation, Acid Number (AN), Base Number (BN), Water Content (Free & Dissolved), Fluid Identity |
| Compliance | ASTM D7889, JOAP Standards |
| Measurement Principle | Mid-Infrared (MIR) Absorption Spectroscopy |
| Sample Volume | 1 Drop (~50 µL) |
| Analysis Time | ≤ 60 Seconds |
| Onboard Database | > 800 Lubricant & Grease Reference Spectra |
| Calibration | Factory-Calibrated with Industry-Validated Algorithms |
| Reporting | Automated PDF Report Generation |
| Software Integration | FluidScan Manager (Windows-based Database & Trending Software) |
| Regulatory Support | Audit Trail, User Access Control, Data Export for GLP/GMP Environments |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-E |
| Portability | Portable |
| Compliance | ASTM D4815 |
| Detection Range | 0–20% and 70–98% ethanol in gasoline |
| Repeatability | ±0.2% (0–20%), ±1.0% (70–98%) |
| Analysis Time | <30 seconds |
| Wavelength | 9.6 µm (1045 cm⁻¹) |
| Power | 18 V DC, 3.3 A |
| Battery Life | >12 hours (rechargeable Li-ion) |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Interface | USB, RS-232 |
| Data Storage | Internal, password-protected |
| Display | Touchscreen LCD |
| Language Support | English, Spanish, French, Arabic |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-SP |
| Detection Limit (Water) | 0.3 ppm |
| Detection Limit (Soil) | 3 ppm |
| Wavelength | 3.4 μm (2930 cm⁻¹) |
| Power | 18 V DC, 3.3 A |
| Weight | 2.6 kg (net), 3.2 kg (with Li-ion battery) |
| Dimensions | 17 cm × 19.8 cm × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Analysis Time | 10–15 min (including extraction) |
| Repeatability | ±0.2 ppm |
| Communication Interface | USB |
| Compliance | EPA Method 1664, EPA Method 1164, ISO 9377-2 |
| Solvents | Hexane, Pentane, Cyclohexane, Vertrel MCA |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 |
| Product Type | Laboratory Instrument |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range (undiluted) | 15–320 cSt |
| Detection of Water Droplets & Air Bubbles | Yes |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Optional Modules | Ferrous Particle Monitoring (ppm + size distribution ≥25 µm), Morphological Imaging & Neural Network-Based Classification (≥20 µm), Kinematic & Dynamic Viscosity Measurement at 40 °C, Automated Sample Processor (ASP) for 24 samples |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 Series |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 10,000,000 particles/mL (<2% error) |
| Viscosity Compatibility | ISO VG 15–320 (no dilution required) |
| Ferrous Particle Detection Time | 20 s |
| Standards Compliance | ASTM D7596, ASTM D6786, ASTM D8120, ISO 4406, NAS 1638, SAE AS4059, NAVAIR 01-1A-17, GOST, HAL |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 Series |
| Type | Portable Instrument |
| Detection Parameters | Particle Counting, Ferrous Particle Concentration & Count (>25 µm), Morphological Wear Debris Classification, Free Water (ppm), Bubble/Contaminant Discrimination |
| Standards Compliance | ASTM D7596, ISO 4406, NAS1638, SAE AS4059, ASTM D6786, ISO 11171 |
| Imaging Technology | Direct High-Resolution CCD Imaging with Laser Illumination |
| Particle Size Range | ≥2 µm (morphology-resolved), ≥20 µm (automated classification), ≥25 µm (ferrous count) |
| Max Sample Contamination Tolerance | 5,000,000 particles/mL |
| Max Soot Tolerance | 2% w/w |
| Auto-Gain Control (AGC) | Yes |
| Onboard Data Management | Asset Tracking, Trend Analysis, Custom Cleanliness Thresholds |
| Dimensions | 35.6 cm H × 36.8 cm W × 78.7 cm D |
| Weight | 8.5 kg |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 230 |
| Detection Capabilities | Simultaneous particle counting, ferrous particle quantification (ppm & size distribution), and morphology-based wear debris classification |
| Particle Size Range (counting) | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range | 15–320 cSt (no dilution required) |
| Soot Tolerance | up to 2% (w/w) |
| Counting Uncertainty | <2% (statistical repeatability) |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Imaging Resolution | ≥20 µm for automated morphology classification |
| Ferrous Sensor Sensitivity | Sub-ppm detection limit for ferrous concentration |
| Analysis Time per Sample | ~4 minutes |