Industry-specific Instruments
Filter
Showing 151–180 of 2098 results
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T1200 |
| Pricing | Available Upon Request |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T1200 PRO |
| Pricing | Available Upon Request |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T2400 PRO |
| Pricing | Available Upon Request |
| Brand | Angstrom |
|---|---|
| Origin | USA |
| Model | Angstrom-dep Powder ALD |
| Base Heating Range | 25–450 °C (optional up to 650 °C) |
| Substrate Uniformity | <1% (Al₂O₃ on 4″ wafer) |
| Precursor Lines | 4 / 6 / 8 configurable |
| Precursor Bottle Capacity & Temp | 100 mL, ambient to 250 °C |
| ALD Valves | Swagelok high-temp valves (150 / 200 / 250 °C options) |
| Carrier Gases | N₂ or Ar |
| Vacuum System | Alcatel mechanical pump (optional Pfeiffer turbomolecular or dry scroll pump) |
| Optional Modules | Load-lock chamber, glovebox integration, cryo-trap, ozone generator, plasma source, in-situ monitoring (QCM, ellipsometry, RGA), exhaust abatement |
| Brand | Ankersmid |
|---|---|
| Origin | Germany |
| Model | OilHealth Probe |
| Type | Online Instrument |
| Application | Lubricating Oil Condition Monitoring |
| Core Technology | Multi-parameter Spectroscopic Analysis (FTIR + Electrochemical RULER + Viscosity Correlation) |
| Compliance Context | Designed for ISO 4406, ASTM D7883 (RULER), ASTM E2412 (FTIR), and OEM lubricant life extension protocols |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FLA 2.1 |
| Price Range | USD 27,000 – 68,000 |
| Brand | Anoxomat |
|---|---|
| Origin | Netherlands |
| Model | GIGA-8dd |
| Input Impedance | 1 GΩ |
| Input Current | <1 pA |
| Signal Gain | 50× to 100× |
| Calibration Pulse | −50 mV |
| Adjustable DC Offset Range | ±0.5 V |
| Maximum Output Voltage | ±5 V |
| Sampling Rate | 100 Hz |
| ADC Resolution | 14-bit |
| Power Supply | 220 VAC / ±8 VDC |
| Interface | USB-connected analog-to-digital converter |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | APN-C |
| Price | USD 8,400 (approx. based on ¥59,800 at 1 USD = ¥7.1) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | APN-I |
| Price | USD 1,400 (approx.) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | APN-III |
| Price | USD 8,400 (approx.) |
| Function Type | Multi-analyte (simultaneous detection of multiple contaminants) |
| Sample Compatibility | Universal for liquid and homogenized food matrices |
| Wavelengths | 410 nm, 538 nm, 590 nm |
| Detection Time | ≤30 minutes per batch |
| Repeatability | ≤1% RSD |
| Detection Channels | 12-position automatic cuvette holder |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤±0.05 nm |
| Detector | Imported CCD sensor |
| Display | 10.1-inch high-resolution LCD |
| Interfaces | RS-232, USB 2.0, built-in thermal printer |
| Power Supply | 12 V DC (including automotive 12 V input) |
| Enclosure | Industrial-grade aluminum alloy portable case |
| Brand | ANPRO |
|---|---|
| Model | APN-M |
| Detection Principle | Colloidal Gold Immunochromatographic Quantitative Assay |
| Target Analyte | Lead (Pb) |
| Detection Limit | 0.02 ppm |
| Quantitative Range | 0–1 ppm |
| Sample Type | Preserved mustard greens and other food matrices |
| Display | Color resistive touchscreen |
| Data Output | Built-in thermal printer |
| Reagent Storage | Ambient-temperature stable test strips |
| Regulatory Alignment | Compliant with GB 5009.12–2023 (China National Food Safety Standard for Determination of Lead in Foods), supports GLP-aligned documentation workflows |
| Origin | Sichuan, China |
| Manufacturer | ANPRO Biotechnology Co., Ltd. |
| Category | Food-Specific Heavy Metal Rapid Detector |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | APN-R |
| Detection Targets | Lead (Pb), Chromium (Cr), and Multi-analyte Screening in Milk & Dairy Products |
| Automation Level | Semi-automatic |
| Throughput | 60 Samples/Hour |
| Detection Range (Pb) | 0–1 ppm (mg/kg) |
| Detection Range (Cr) | 0–5 ppm (mg/kg) |
| Repeatability (CV) | <3% |
| Accuracy | >80% |
| Onboard Storage | 2 GB |
| LOD (Pb in raw/pasteurized/UHT milk) | 0.001 ppm |
| LOD (Pb in other dairy matrices) | 0.01 ppm |
| LOD (Cr) | 0.1 ppm |
| Assay Time | 6 min per test |
| Reaction Temperature | 37 °C |
| Calibration | Pre-loaded multi-point standard curves for Pb, Cr, and 12+ additional analytes (e.g., Aflatoxin M1, Chloramphenicol, Melamine) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APN-S |
| Price | USD 6,800 (FOB) |
| Brand | Anpro |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | EV-X |
| Pricing | Upon Request |
| Brand | Anpro |
|---|---|
| Model | EV-X |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Automated Immunoassay Analyzer for Mycotoxins, Heavy Metals & Pesticide Residues |
| Compliance | GB 2761–2017, GB 2762–2022, LST 6111–2015 to LST 6114–2015, LST 6144–2023, LST 6145–2023 |
| Throughput | ≥20 samples/hour (40 test results/hour) |
| Sample Capacity | 10 independent reaction channels |
| Detection Principle | Quantitative Enzyme-Linked Immunosorbent Assay (ELISA) with photometric readout |
| Sample Types | Cereals, oilseeds, feedstuffs, edible oils, dairy products, traditional Chinese medicinal materials |
| Key Analytes | Aflatoxin B₁, Aflatoxin M₁, Total Aflatoxins, Deoxynivalenol (DON), Zearalenone (ZEN), Fumonisins, Ochratoxin A, T-2 Toxin, Pb, Cd, Cr, Cu, Acetamiprid, Emamectin benzoate, Isoprocarb, Carbaryl, Parathion-methyl, Lambda-cyhalothrin |
| LOD Range | 0.01–10 ppb (mycotoxins), 0.01–0.1 ppm (pesticides), 0.02–0.1 ppm (heavy metals) |
| Liquid Handling Accuracy | ≤1% CV |
| Automation Scope | Full unattended workflow — sample loading, extraction, dilution, reagent preheating, cartridge preheating, incubation, optical detection, and data upload |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | NJ-IA |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Detection Channels | 20 |
| Measurement Error | < 0.01 Absorbance Units |
| LOD (Dichlorvos) | ≤ 0.2 mg/L |
| Additional LODs | Parathion ≤ 0.8 mg/L, Chlorpyrifos ≤ 0.16 mg/L, Phoxim ≤ 0.2 mg/L, Methamidophos ≤ 1.2 mg/L, Carbaryl ≤ 0.24 mg/L, Malathion ≤ 1.5 mg/L, Carbofuran ≤ 0.04 mg/L, Methomyl ≤ 0.1 mg/L, Isoprocarb ≤ 0.28 mg/L, Omethoate ≤ 0.44 mg/L, Dichlorvos ≤ 0.1 mg/L |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SKJ-IA |
| Pricing | Upon Request |
| Function Type | Multi-analyte Quantitative Detection Platform |
| Sample Applicability | Universal for Grains, Feed, Fruits, Vegetables, Tea, Dairy Products |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | 15–30 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 independent optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SKJ-IA |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Versatility | Universal for Solid & Liquid Food Matrices |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤25 min |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 simultaneous independent channels |
| Detection Range (Cd & Pb) | 0–1 ppm |
| Regulatory Alignment | Designed to support ISO 17025-compliant workflows and GLP-aligned food safety testing |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SKJ-IA-01 |
| Instrument Class | Multi-Mycotoxin Immunoassay Analyzer |
| Detection Principle | Colloidal Gold-Based Lateral Flow Immunoassay (Quantitative) |
| Throughput | 6 samples per run |
| Assay Time per Sample | ≤10 min |
| Display | 7-inch capacitive touchscreen |
| Integrated Thermal Printer | Yes |
| Data Connectivity | Wi-Fi / USB / Optional 4G module |
| Regulatory Validation | Official evaluation reports issued by the State Grain Administration (China) for AFB1, DON, ZEN, and OTA |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | SKJ-IA-03 |
| Price Range | USD 7,000 – 14,000 |
| Detection Principle | Competitive Enzyme-Linked Immunosorbent Assay (ELISA) with Quantitative Lateral Flow Readout |
| Sample Throughput | 6 samples per run |
| Analysis Time | ≤10 minutes per sample |
| Target Analytes | Cd, Pb, Cu, Hg |
| Detection Ranges | Cd: 0–1 ppm |
| Pb | 0–1 ppm |
| Cu | 0–20 ppm |
| Hg | 0–0.3 ppm |
| Sample Types | Raw grains (rice, wheat, corn, barley), milled grain products, animal feed, feed ingredients, botanical herbal materials |
| Display | Color resistive touchscreen (≥7″) |
| Data Output | Onboard thermal printer, GPS-tagged CSV export via Wi-Fi/4G, API-compatible JSON upload to LIMS or cloud platforms |
| Regulatory Alignment | Compliant with GB 5009.15–2014 (Cd), GB 5009.12–2023 (Pb), and aligned with AOAC Official Method 2019.02 for immunoassay-based heavy metal screening in cereals |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-04 |
| Price Range | USD 7,000 – 14,000 |
| Functionality | Multi-analyte (Cd, Pb, Cu, Cr) |
| Sample Versatility | Universal for solid and liquid food matrices |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤25 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 parallel optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-05 |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Versatility | Universal for Herbal Materials, Decoction Pieces, Animal-derived Herbs |
| Optical Wavelength | 410 nm |
| Detection Time per Sample | ≤25 minutes |
| Repeatability (RSD) | ≤0.2% |
| Detection Channels | 6-channel simultaneous measurement |
| Detection Range | Cd 0.1–5 mg/kg, Pb 0.2–10 mg/kg, Cu 2–50 mg/kg |
| Accuracy | Cd ≥80%, Pb ≥80%, Cu ≥75% |
| Compliance Reference | Chinese Pharmacopoeia (2020 Ed., Vol. IV, General Chapter 0412 & 2341) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | SKJ-IA-C |
| Price | USD 7,000 (approx.) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | SKJ-IA-III |
| Function Type | Multi-Analyte (Heavy Metals, Mycotoxins, Pesticides) |
| Sample Compatibility | Universal (Grains, Feed, Fruits, Vegetables, Dairy, Tea) |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤18 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 parallel optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-Z |
| Instrument Category | Aflatoxin Analyzer |
| Detection Principle | Immunochromatographic Colloidal Gold Assay |
| Display | 7-inch Capacitive Touchscreen |
| Test Format | Single-use, individually packaged lateral flow test strips |
| Storage Condition | Ambient Temperature |
| Detection Time | ≤8 min per assay |
| LOD | 1 ppb |
| Quantitative Range | 2–150 ppb for AFB₁ and Total Aflatoxins (B₁+B₂+G₁+G₂) |
| Regulatory Alignment | Compliant with 2015 Edition of Chinese Pharmacopoeia (ChP), Section on Aflatoxin Testing for 19 TCM materials |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SKJ-IA/01 |
| Instrument Category | Multi-Mycotoxin Immunoassay Analyzer |
| Detection Principle | Lateral Flow Immunoassay with Colloidal Gold Quantification |
| Sample Throughput | 6 samples per run |
| Assay Time | 8–10 min per test |
| Display | 7-inch capacitive touchscreen |
| Integrated Thermal Printer | Yes |
| Data Connectivity | USB, Wi-Fi, Ethernet |
| Regulatory Validation | Verified by National Grain Administration Quality Inspection Center (China) for AFB1, DON, ZEN, OTA |
| Storage | Ambient (no refrigeration required for test strips) |
| Test Strip Format | Individually sealed single-use cassettes |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | SKJ-IA/02 |
| Instrument Category | Aflatoxin B1 Analyzer |
| Detection Principle | Immunochromatographic Colloidal Gold Quantification |
| Sample Throughput | 6 samples per run |
| Detection Time per Sample | ≤10 min |
| Display | 7-inch capacitive touchscreen |
| Integrated Thermal Printer | Yes |
| Test Strip Format | Individually packaged lateral flow strips, ambient storage stable |
| Regulatory Validation | Certified by the National Grain and Oils Quality Inspection Center (China) for AFB1, DON, ZEN, OTA, FB1, and T-2 toxin |
| Data Connectivity | Cloud-ready |
| Quantitation Range (AFB1) | 0–150 ppb |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | SKJ-IA/03 |
| Price Range | USD 8,500 – 11,500 |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | SKJ-IA/04 |
| Instrument Category | Multi-Mycotoxin Immunoassay Analyzer |
| Detection Principle | Lateral Flow Immunoassay with Colloidal Gold-Based Quantitative Signal Readout |
| Display | 7-inch Capacitive Touchscreen |
| Data Connectivity | Wi-Fi / USB / Optional Cloud API Integration |
| Sample Throughput | Up to 6 samples per run |
| Assay Time | ≤10 min per test |
| Storage Condition for Test Strips | Ambient (15–30 °C), Individually Sealed |
| Regulatory Validation | Certified by National Grain Quality Inspection Center (China) per GB/T 28717–2012 and relevant grain safety standards |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SKJ-IA/I |
| Pricing | Upon Request |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Applicability | Universal for Cereals, Feed, Fruits, Vegetables, Tea, Dairy |
| Wavelength | 410 nm |
| Assay Time | 25 minutes per sample |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 independent optical channels |
