Infrared Spectrometer
Filter
Showing 121–150 of 180 results
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | AtmosFIRair |
| Instrument Type | Portable FTIR Spectrometer |
| Wavenumber Range | 485–8500 cm⁻¹ |
| Resolution Options | 1, 2, 4, or 8 cm⁻¹ |
| Scan Speed | Up to 1 spectrum per second (resolution-dependent) |
| Signal-to-Noise Ratio | >20,000:1 (peak-to-peak, 1-min acquisition), >120,000:1 (RMS, 1-min acquisition) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Brand | PSC |
|---|---|
| Origin | USA |
| Model | mIRage |
| Instrument Type | Laboratory Benchtop System |
| Spectral Range | IR (3600–800 cm⁻¹), Raman (3900–200 cm⁻¹) |
| Spatial Resolution | ~500 nm |
| Measurement Mode | Non-contact, Reflection-Based Optical Photothermal Infrared (O-PTIR) |
| Compliance | Fully Compatible with ASTM E1252, ISO 18387, USP <1119>, FDA 21 CFR Part 11 (via optional audit-trail software module) |
| Software Platform | mIRage Pro v4.2 with GLP/GMP-ready data integrity controls |
| Brand | PSC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | mIRage-LS |
| Instrument Category | Laser-Based Infrared Spectrometer |
| Instrument Type | Laboratory Benchtop System |
| Wavenumber Range | 3600–800 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Scan Speed | 1 scan per 60 seconds |
| Signal-to-Noise Ratio (SNR) | 45,000:1 |
| Wavenumber Accuracy | ≤0.5 cm⁻¹ |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Microscope |
| Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio | 30,000:1 |
| Optical Magnification Range | 330× continuous (macro to micro, 10 mm × 13 mm to 30 µm × 40 µm) |
| Detector | Liquid Nitrogen-Cooled MCT (Mercury Cadmium Telluride) |
| Automation | Fully Motorized XYZ Stage with Digital Image-Based Auto-Targeting |
| Software | IRsolution with Integrated Chemical Imaging and Automated Contaminant Identification Algorithm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AIRsight |
| Instrument Type | Laboratory Benchtop System |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | IRPrestige-21 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.85 cm⁻¹ |
| Scan Velocity | 0.2–2.5 cm/s |
| Signal-to-Noise Ratio | 15,000:1 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Resolution | 0.9 cm⁻¹ |
| Scan Speed | 45 scans/min (at 4 cm⁻¹ resolution) |
| Signal-to-Noise Ratio | 30,000:1 |
| Form Factor | Compact, Dual-Orientational (Horizontal/Vertical Placement) |
| Sample Compartment | Large-volume chamber compatible with Shimadzu and third-party FTIR accessories |
| Software | IR Pilot with 23 preconfigured application workflows, qualitative identification module, and pass/fail foreign material analysis module |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | IRTracer-100 |
| Instrument Type | Laboratory Benchtop |
| Instrument Class | Fourier Transform Type |
| Price Range | USD 35,000 – 70,000 (FOB Japan) |
| Key Performance | SNR up to 60,000:1 (DLATGS detector, 4 cm⁻¹, 2,200 cm⁻¹ region, 1-min scan) |
| Spectral Resolution | 0.25–16 cm⁻¹ (user-selectable) |
| Acquisition Speed | Up to 20 spectra/sec (at 16 cm⁻¹) |
| Detector Options | DLATGS (standard), MCT (optional, liquid N₂-cooled) |
| Software Platform | LabSolutions IR v2.x or later |
| Compliance | FDA 21 CFR Part 11, PIC/S Annex 11, GLP/GMP-ready audit trail & electronic signature support |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IRXross |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 55,000:1 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIR |
| Pricing | Available Upon Request |
| Wavelength Ranges | SIR-1700: 400–1700 nm |
| SIR-2600 | 0.9–2.6 µm |
| SIR-3400 | 1–3.4 µm |
| SIR-5000 | 2–5 µm |
| SIR-6500 | 3.0–6.5 µm |
| Interface | USB 2.0 |
| Software | Integrated control and spectral analysis suite |
| Brand | SOC/SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SOC400 / SOC400T |
| Pricing | Available Upon Request |
| Brand | Specac |
|---|---|
| Origin | United Kingdom |
| Model | Atlas |
| Max Operating Temperature | 300 °C or 400 °C |
| Adjustable Film Thickness | 15, 25, 50, 100, 250, 500 µm |
| Sample Diameter | 29 mm |
| Configuration Options | Standalone press unit (15631/15800) or integrated press + manual 15-ton hydraulic press (15633/15810) |
| Compliance | Designed for ASTM E1252, ISO 18381, and USP <1118> FTIR sample preparation |
| Brand | Spectral Products |
|---|---|
| Origin | USA |
| Model | SM301 / SM301-EX |
| Instrument Type | Portable |
| Spectral Range | 1.0–3.0 µm (PbS) or 1.5–5.0 µm (PbSe) |
| Spectral Resolution | 10–30 nm (dependent on slit width and grating) |
| Detector | 256-element PbS or PbSe linear array |
| Pixel Size | 45 µm × 450 µm |
| Pixel Clock | up to 2 MHz |
| Data Output Rate | up to 4 MHz |
| Integration Time | 0.01–200 ms (onboard) |
| Slit Options | 10, 25, 50, 100 µm (default: 25 µm) |
| f/# | 3.5 |
| Cooling | TE-cooled to –15 °C ARO (down to –20 °C ARO optional) |
| Dark Noise | ~20 RMS counts (16-bit, balanced) |
| SNR | 4000:1 |
| Stray Light | < 0.1% |
| Interface | USB 1.1/2.0, 16-bit |
| Software | SM32Pro & SMProMX (Windows XP–10, 32/64-bit), DLL & SDK included |
| Dimensions | 173 × 120 × 98.1 mm |
| Weight | 2.5 kg |
| Optical Coupling | SMA 905 or FC connector |
| Trigger Modes | Free-running or external TTL |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | SP301 / SP301-EX |
| Pricing | Upon Request |
| Instrument Class | Optical Photothermal Infrared Spectrometer |
| Form Factor | Portable |
| Wavenumber Range | 3333–10000 cm⁻¹ (equivalent to 1.0–3.0 µm for PbS |
| Spectral Resolution | 10–30 nm (dependent on slit width and grating selection) |
| Signal-to-Noise Ratio | ≥20 RMS counts (16-bit digitization) |
| Detector Cooling | Thermoelectric (TE), down to –20 °C |
| Detector Type | Linear PbS or PbSe array (256 pixels, 45 µm × 450 µm active area) |
| Max Readout Rate | 2 MHz |
| Linearity | >90% |
| Pixel-to-Pixel Response Uniformity (peak-to-peak) | ±10% |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP304 |
| Instrument Class | Optical Photothermal Infrared Spectrometer |
| Form Factor | Portable |
| Wavelength Ranges | 0.9–1.7 µm, 0.9–2.05 µm, 0.9–2.2 µm, 0.9–2.5 µm |
| Spectral Resolution | >3 nm (overall, depending on configuration) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms integration time |
| Detector Types | 256- and 512-pixel TE-cooled InGaAs linear arrays |
| Pixel Dimensions | 25 × 250 µm or 25 × 500 µm (model-dependent) |
| Compliance | CE, RoHS, ISO 9001-aligned manufacturing & calibration protocols |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | ET10 |
| Instrument Type | Handheld Portable Emissometer |
| Spectral Bands | 3–5 µm and 8–12 µm |
| Measurement Principle | Directional-Hemispherical Reflectance (DHR) → Emissivity = 1 − R(λ) for Opaque Materials |
| Accuracy | ±1% |
| Repeatability | ±0.0002 |
| Incident Angle | 20° off-normal (quasi-normal illumination) |
| Sample Compatibility | Flat or curved surfaces (min. radius 6″ convex / 12″ concave) |
| Measurement Time | 7 s per dual-band acquisition |
| Warm-up Time | 90 s |
| Battery Life | 2 h (rechargeable NiMH) |
| Weight | 4.7 lbs (2.13 kg) with battery |
| Dimensions | H 11.54″ × L 9.04″ × W 3.72″ (293 × 229 × 94 mm) |
| IR Source | CoCrAl alloy filament, operated at ~1000 °C |
| Data Storage | 265 MB CompactFlash card |
| Output Formats | CSV and plain-text (compatible with Excel, MATLAB, Python pandas) |
| Operating Environment | 0–40 °C, non-condensing |
| Storage Range | −25 to 70 °C |
| Interface | Touch-enabled LCD PDA with graphical UI and soft keys |
| Modularity | Interchangeable measurement heads |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Nicolet iS10 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | Better than 0.4 cm⁻¹ |
| Scan Speed | 40 spectra/sec |
| Signal-to-Noise Ratio | >50,000:1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet Summit |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 8000–350 cm⁻¹ |
| Resolution | 0.5 cm⁻¹ |
| Scan Speed | 130,000 scans/sec |
| Signal-to-Noise Ratio | 40,000:1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TruDefender FT |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared Spectroscopy |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 2 scans/sec |
| Weight | 1.3 kg |
| Dimensions | 19.6 × 11.2 × 5.3 cm |
| Optical Interface | Diamond ATR Crystal |
| Environmental Rating | MIL-STD-810F & IP67 |
| Battery Life | >4 hours (rechargeable Li-ion or CR123A primary cells) |
| Operating Temperature | −25 °C to +40 °C |
| Data Export Formats | SPC, TXT, JPEG |
| Compliance | ASTM E2534 (for field-deployable chemical ID), GLP/GMP-ready audit trail support in firmware |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruDefender FTX |
| Instrument Category | Fourier Transform Infrared (FTIR) |
| Form Factor | Portable |
| Wavenumber Range | 4,000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Signal-to-Noise Ratio | ≥1,000:1 (typical, 32 scans, ambient conditions) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iS10 |
| Instrument Type | Fourier Transform |
| Optical Design | Sealed, Desiccated Interferometer with Dynamic Alignment |
| Detector | DTGS (Deuterated Triglycine Sulfate) |
| Scan Speed | Up to 5 scans/sec (standard mode) |
| Spectral Resolution | Adjustable down to 0.4 cm⁻¹ |
| Wavelength Range | 4000–400 cm⁻¹ |
| Beam Splitter | KBr |
| Compliance | ASTM E1421, ISO 18382, USP <1119>, GLP/GMP-ready data integrity architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet 6700 |
| Price Range | USD 32,000 – 38,500 (FOB) |
| Instrument Type | FT-IR |
| Configuration | Benchtop Laboratory System |
| Wavenumber Range | 7800 – 350 cm⁻¹ |
| Spectral Resolution | < 0.09 cm⁻¹ |
| Scan Speed | 130,000 scans per second (DSP-controlled interferometer) |
| Signal-to-Noise Ratio | 50,000:1 (peak-to-peak, 4 cm⁻¹, 1 min scan, KBr beam splitter, DTGS detector) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Nicolet Apex FTIR Spectrometer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Nicolet Series |
| Instrument Type | Laboratory-Based |
| Spectrometer Type | Fourier Transform (FT-IR & FT-Raman) |
| Application Domain | Molecular Spectroscopy & Surface Analysis |
| Compliance Framework | ASTM E1421, ISO 17025, USP <1119>, FDA 21 CFR Part 11 (Software Validation Ready), GLP/GMP-Ready Data Integrity Architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet iS10 |
| Instrument Type | Fourier Transform |
| Compliance Standards | ASTM E1421, NIST-traceable, USP <1119>, EP 2.2.24, JP 2.07, FDA 21 CFR Part 11 (with ValPro™ and OMNIC Security Suite) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS20 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | Not specified (custom-configurable per application) |
| Spectral Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 50,000:1 (at 4 cm⁻¹, 1 min scan, KBr beam splitter) |
| Wavenumber Accuracy | ±0.02 cm⁻¹ at 2000 cm⁻¹ |
| Optical Engine | LightDrive™ Interferometer Platform |
| Warranty | 10-year limited warranty on interferometer, laser, and IR source |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS5 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 350–7800 cm⁻¹ |
| Spectral Resolution | Better than 0.8 cm⁻¹ |
| Scan Speed | Up to 10 scans per second |
| Signal-to-Noise Ratio (SNR) | > 1 × 10⁵ (peak-to-peak, 4 cm⁻¹ resolution, 1 min scan) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iS5 |
| Instrument Type | Fourier Transform |
| Software Platform | OMNIC™ Spectroscopy Software |