Infrared Spectrometer
Filter
Showing 91–120 of 186 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR 702L |
| Instrument Type | In-line / Flow-through Process Analytical Technology (PAT) System |
| Spectral Range | 4000–800 cm⁻¹ |
| Detector | Solid-State Cooled MCT (Mercury Cadmium Telluride) |
| Optical Interface | Fiber-Optic Probe Coupling (No Purge Gas Required) |
| Configuration | Benchtop, Stackable, Vent-Hood Compatible |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR™ 45m, ReactIR™ 45p |
| Instrument Type | In-situ, Real-time Online FTIR Spectrometer |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 2000:1 |
| Scan Speed | Not specified (typical for high-stability process-grade FTIR) |
| Probe Materials | Diamond, Silicon, Zirconia ATR crystals |
| Wetted Materials | Hastelloy®, Gold |
| Temperature Range | −80 °C to 200 °C (optional up to 300 °C) |
| Pressure Rating | Vacuum to 7 bar (optional up to 350 bar) |
| Probe Diameters | 6.35 mm, 9.5 mm, 16 mm, 25.4 mm |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | I-Series |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 4000–7500 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Scan Speed | 8 s per spectrum |
| Signal-to-Noise Ratio | <1% (RMS, 100 scans) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ across 4000–7500 cm⁻¹ |
| Brand | MKS |
|---|---|
| Origin | USA |
| Model | MG6030 |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 10 ppb to 100% (gas-phase concentration) |
| Spectral Resolution | 0.5–128 cm⁻¹ |
| Scan Speed | 5 scans/sec at 0.5 cm⁻¹ |
| Detector | Liquid-nitrogen-cooled or thermoelectrically cooled MCT (HgCdTe) |
| Optical Path Length | 5.11 m |
| Purge Gas | Dry N₂ or CO₂-free air (dew point < −70 °C), flow rate 0.2 L/min |
| Pressure Sensor | MKS Baratron® capacitance manometer |
| Sample Temperature Range | Ambient to 200 °C |
| Sample Flow Rate | 0.2–10 L/min |
| Sample Pressure Range | 0.01–4 atm |
| Enclosure Material | Nickel-plated aluminum or 316 stainless steel |
| Weight | 50 kg |
| Dimensions | 445 mm (W) × 318 mm (H) × 648 mm (D) |
| Power | 110/220 VAC, 50/60 Hz, 3 A |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 490–8500 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Scan Speed | ≤3 s per spectrum |
| Signal-to-Noise Ratio | 15,000:1 |
| Optical Path Design | Low-volume, heated long/short-path gas cell |
| Gas Cell Temperature Control | ±1 °C |
| Operating Ambient | IP50 (optional IP53) |
| Power Supply | 100–240 VAC ±10%, 50–60 Hz ±3 Hz |
| Power Consumption | 550 W (startup), 200 W (steady-state), +400 W (gas cell heater max) |
| Sample Gas Flow Rate | 0–10 LPM |
| Calibration Gas Requirements | Certified standard gases traceable to NIST or equivalent |
| Brand | MVI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Vista-IR |
| Instrument Category | Laser-Based Infrared Spectrometer |
| Instrument Type | Laboratory Benchtop System |
| Wavenumber Range | 760–4400 cm⁻¹ |
| Spatial Resolution | <10 nm |
| Spectral Resolution | <2 cm⁻¹ |
| Scan Rate | 10 spectra/sec |
| Signal-to-Noise Ratio | 100:1 |
| Brand | Neaspec |
|---|---|
| Origin | Germany |
| Model | o-FTIR |
| Instrument Type | Laboratory-based FTIR Spectrometer |
| Spatial Resolution | 10 nm |
| Spectral Resolution | 3.0 cm⁻¹ |
| Acquisition Speed | 3 spectra/s |
| Signal-to-Noise Ratio | 80:1 |
| Spectral Range | 0.5–20 µm (Visible to Mid-IR) |
| Illumination Mode | Reflection-mode AFM tip illumination |
| Detection | Interferometric scattering near-field detection with background-free architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | Nicolet 6700, Nicolet 8700 |
| Instrument Type | Fourier Transform Infrared (FT-IR) Spectrometer |
| Spectral Range | 27,000–15 cm⁻¹ |
| Resolution | 0.09 cm⁻¹ (max), 0.4 cm⁻¹ (standard) |
| SNR | 50,000:1 (peak-to-peak, 1-min scan) |
| Interferometer | Digitally Controlled ETC-Driven VECTRA™ with 130,000 dynamic adjustments/sec |
| Light Source | Electronically Temperature-Controlled (ETC) EverGlo™ IR Source (US Patent #US5291022) |
| Detector Options | Plug-and-Play Mid-IR, Far-IR, UV-Vis, and Liquid-Nitrogen-Cooled MCT (18-h hold time) |
| Data Interface | USB 2.0 |
| Software Platform | OMNIC™ with FDA 21 CFR Part 11 Compliance Support |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Brand | ONUEE |
|---|---|
| Origin | France |
| Model | EMIR-PAS |
| Instrument Type | Tunable Quantum Cascade Laser-Based Mid-IR Photoacoustic Spectrometer |
| Detection Principle | Laser Photoacoustic Spectroscopy (LPAS) |
| Key Gases | H₂O, NO, NO₂, CO, CO₂, NH₃, CH₄, N₂O, SF₆ |
| Detection Limit | Sub-ppm (gas-dependent) |
| Accuracy | <1% of reading or LOD |
| Repeatability | <1% of reading or LOD |
| Response Time (T90) | Typically <5 s |
| Measurement Frequency | Up to 10 Hz |
| Sample Flow Rate | <80 mL/min |
| Cell Volume | 1 mL |
| Operating Pressure | 0.5–2 bar.a (requires integrated pressure sensor) |
| Power Supply | 24 V DC, ~10 W |
| Communication | RS485, Modbus RTU |
| Dimensions | 115 × 170 × 108 mm |
| Weight | <2 kg |
| Environmental Operating Range | 10–30 °C, 0–95% RH (non-condensing) |
| Compliance | Designed for industrial integration in EPA-, ISO-, and IEC-compliant monitoring systems |
| Brand | Optec |
|---|---|
| Origin | Beijing, China |
| Model | PEM |
| Instrument Type | Portable |
| Spectral Range | 1–50 µm |
| Scan Speed | 3 s per measurement |
| Measurement Principle | Directional-Hemispherical Reflectance (DHR) via Integrating Sphere Reflectometry |
| Output Parameters | Hemispherical Emissivity, Directional-Hemispherical Reflectance at 20° and 60° incidence |
| Measured Bands | Dual-band simultaneous output — 3–5 µm and 8–14 µm (PEM100) |
| Accuracy | ±0.01 (PEM10), ±0.02 (PEM100) |
| Repeatability | ±0.005 (PEM10), ±0.01 (PEM100) |
| Incidence Angles | 20° normal incidence (PEM10) |
| Calibration Standard | Gold-coated reference mirror |
| Power Supply | Rechargeable Li-ion battery |
| Weight | 0.6 kg (PEM10), <1.0 kg (PEM100), both including battery |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Price Range | USD 1,400 – 140,000 |
| Brand | Paeonia Innovations |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Instrument Type | Online |
| Wavenumber Range | 900–1800 cm⁻¹ |
| Dimensions | 50 × 55 × 60 mm |
| Weight | 450 g |
| Response Time | 0.3 s |
| Operating Pressure | 0–5 bar |
| Operating Temperature | −15 °C to +60 °C |
| Flow Path Fitting | 1/8″ NPT or Swagelok |
| Power Supply | 5 V DC via USB-C |
| Software Platform | Windows 10 & 11 Native Application for Real-Time Data Acquisition and Instrument Control |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectrum 3 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Instrument Category | Fourier Transform Type |
| Wavenumber Range | Not Specified |
| Resolution | Not Specified |
| Scan Speed | Up to 100 scans/sec |
| Signal-to-Noise Ratio | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | L160000A |
| Instrument Type | Benchtop Laboratory FT-IR Spectrometer |
| Wavenumber Range | 350–7500 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Wavenumber Accuracy | ±0.1 cm⁻¹ |
| Wavenumber Precision | ±0.01 cm⁻¹ |
| Signal-to-Noise Ratio | 9,300:1 (5 scans, peak-to-peak), 32,000:1 (60 sec scan, peak-to-peak) |
| Detector | High-performance DTGS or optional MCT |
| Interferometer | DynaScan™ permanent alignment, no moving mirrors |
| Beamsplitter | KBr-coated |
| Optical Enclosure | Sealed, desiccated cavity with OpticsGuard™ moisture protection |
| Dimensions | 450 × 300 × 210 mm |
| Weight | 13 kg |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spectrum Two |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Instrument Category | Fourier Transform Infrared (FTIR) Spectrometer |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spotlight 400/400N |
| Instrument Type | Laboratory FT-IR Imaging System |
| Detector Architecture | Patented Linear Array MCT Detector |
| Spectral Range | Up to 720 cm⁻¹ (Mid-IR) and Extended NIR Capability |
| Spatial Resolution | 1.56 µm (ATR mode), 6.25 µm / 25 µm / 50 µm (Transmission/Reflection modes) |
| Imaging Speed | Up to 170 spectra/sec |
| Scan Modes | Single-region, Multi-region, Unattended Overnight Acquisition |
| Sample Stage | Motorized, High-Precision, Repeatability ±0.001% |
| Optional Accessories | Imaging ATR, Large-Area Sample Stage |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 160-1900 |
| Type | Laboratory-Scale IR Sample Preparation Accessory |
| Material | Hardened Stainless Steel |
| Sample Diameter | 13 mm |
| Vacuum Interface | Standard Negative-Pressure Port |
| Includes | Stainless Steel Base with Vacuum Port, 13 mm Die Cavity, Two Polished Pressure Anvils, Precision-Machined Plunger, Two O-Rings (for Plunger Seal and Base Mounting) |
| Surface Finish | Mirror-Polished Contact Surfaces |
| Compliance | Designed for ASTM E1252 and USP <1119> FTIR Sample Preparation Protocols |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 160-8010 |
| Purity | Spectroscopic Grade |
| Form | Fine Crystalline Powder |
| Packaging | 100 g Bottle |
| Application | FTIR Sample Preparation (Transmission Pellet & DRIFTS Background) |
| Compliance | Meets ASTM E1421 and ISO 18387 specifications for IR-transparent matrix materials |
| Storage | Desiccated, Room Temperature |
| Hygroscopicity | High — Requires Handling in Dry Atmosphere (<10% RH) |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 16x-xxx (Compatible with TL011-1000 configuration) |
| Mounting Interface | Universal FTIR Beam Port |
| Incident Angle | 30° ± 0.5° |
| Sample Holder Options | 3/8", 1/4", and 3/16" diameter sample caps |
| Optical Path | Fixed-angle, non-adjustable specular geometry |
| Compatibility | Bruker Tensor, Thermo Nicolet iS Series, PerkinElmer Frontier, Agilent Cary 630/670, Shimadzu IRTracer, and domestic FTIR systems with standard KBr beam path exit |
| Material | Gold-coated aluminum mirror optics (R > 98% @ 4000–400 cm⁻¹) |
| Weight | 185 g |
| Dimensions (L×W×H) | 82 × 54 × 32 mm |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | P042-1000 |
| Compatibility | Varian, Shimadzu, Bruker, PerkinElmer FTIR spectrometers |
| Mounting | Base-mounted |
| Optical Design | Monolithic mirror construction |
| Adjustment | Micrometer-driven sample cup positioning |
| Performance | Optimized infrared beam path for high throughput and signal-to-noise ratio |
| Optional Variants | Gold-coated, NIR-specific, external large-sample, heated, and automated multi-sample versions |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 16XX-XX |
| Instrument Type | Laboratory FTIR Accessory |
| FTIR Spectral Range | 7800–400 cm⁻¹ |
| Optical Resolution | 0.5 cm⁻¹ |
| Scan Speed | 1 scan/sec |
| Signal-to-Noise Ratio | 15,000:1 |
| Temperature Control Range | Ambient to 200 °C |
| Window Material Options | CaF₂, BaF₂, ZnSe, KBr, CsI (selected per spectral region) |
| Window Dimensions | Ø32 mm × 3 mm thick |
| Clear Aperture | 13 mm diameter |
| Pathlength Options | Fixed via precision-machined metal spacers (e.g., 0.025 mm, 0.1 mm, 0.5 mm, 1.0 mm) |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Configuration | Universal Mounting Interface for FTIR Spectrometers |
| Mirror Coating | Electroless Gold (Au) |
| Incident Angle | 80° ± 0.5° |
| Polarization Capability | Manual Rotatable Polarizer Holder |
| Compatibility | Bruker, Shimadzu, Thermo Fisher Scientific, PerkinElmer, Varian (Agilent) FTIR Platforms |
| Optical Path | Fixed-geometry, Non-Imaging Grazing Incidence Beam Path |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Cell Volume | 38.5 mL |
| Path Length | 100 mm |
| Max Operating Temperature | 260 °C |
| Maximum Pressure Rating | 100 psi |
| Construction | Stainless Steel Body with O-ring Seals |
| Window Mounting | 38 × 6 mm Rectangular Aperture (Windows Not Included) |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Type | Manual or Motorized Polarizer |
| Mounting Format | Standard 2" × 3" Spectroscopy Sample Holder |
| Clear Aperture | Ø20 mm |
| Total Diameter | Ø25 mm |
| Angular Accuracy (Manual) | ±2° |
| Angular Accuracy (Motorized) | ±0.5° |
| Compatibility | Universal with FTIR spectrometers (including Pike ATR, 80° Mirror, Grazing Angle Accessories) |
| Control Interface | Manual rotation or RS-232/USB motorized positioning |
| Software Integration | AutoPRO™ for automated polarization-resolved spectral acquisition |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Optical Path Length Options | Fixed (2.4 m, 10 m, 22 m, 33 m) or Variable (1–16 m) |
| Temperature Control Range | –200 °C to +200 °C (±1.0 °C stability) |
| Window Materials | BaF₂, CaF₂, KBr, KRS-5, NaCl, ZnSe |
| Mirror Coating | Gold-coated stainless steel |
| Compatible FTIR Systems | Thermo Nicolet, Bruker Tensor/Vertex, Shimadzu IRTracer, Varian Excalibur |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Compatibility | Universal for 13 mm KBr pellets and thin films ≤ 0.5 mm thickness |
| Construction | Steel base plate with precision-machined alignment pins + magnetic stainless-steel cover plate |
| Application | FTIR transmission mode only |
| Mounting | Standard 25.4 mm (1") optical post or benchtop fixture |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Optical Path Length | 100 mm |
| Construction | Borosilicate Glass Body with Precision-Machined Aluminum Ring and Mounting Frame |
| Compatible Window Material | 25 mm × 4 mm (Thickness) IR-Transmissive Windows (e.g., KBr, ZnSe, CaF₂) |
| Mounting Interface | Standard FTIR Sample Compartment Compatibility (e.g., Thermo Nicolet, Bruker, PerkinElmer) |
| Brand | Pike Technologies |
|---|---|
| Material Options | KBr, ZnSe, CaF₂ |
| Diameter Options | 13–50 mm (standard increments) |
| Surface Quality | λ/4 @ 633 nm |
| Parallelism | < 10 arcsec |
| Coating | Optional AR coating (3–12 µm broadband) |
| Compliance | ASTM E1421-22 (IR Spectroscopy Calibration Standards), ISO 17025 traceable manufacturing |
| Packaging | Cleanroom-sealed, desiccated blister packs |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 16x-xxx |
| Pricing | Available Upon Request |
