Empowering Scientific Discovery

Jiangsu Skyray Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelVOC-2000
Detection PrinciplePhotoionization Detection (PID)
Instrument TypePortable
Typical ConfigurationTotal VOC (TVOC) Analyzer
Measurement Range0–40,000 ppm (isobutylene equivalent)
Resolution0.1 ppm
Accuracy±10% of reading
Response Time (T90)<4 seconds
Operating SystemAndroid-based embedded OS
Display4-inch capacitive touchscreen
ComplianceHJ 1019–2019 (China Technical Guideline for Sampling VOCs in Soil and Groundwater)
Data ExportUSB mass storage & wireless (Wi-Fi/Bluetooth)
ConnectivityBuilt-in Wi-Fi, Bluetooth 4.2, QR code sharing
PowerRechargeable Li-ion battery (≥8 h typical operation)
Environmental RatingIP54
Weight≤420 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelEVOCs-1000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelVOC-3800
Detection PrincipleFlame Ionization Detection (FID) & Photoionization Detection (PID)
Instrument TypePortable
ConfigurationDual-sensor VOC Analyzer (FID + PID)
Response TimeFID: ≤3.5 s, PID: ≤3.5 s
Safety CertificationIntrinsically Safe (Ex ib IIB T4 Gb)
Hydrogen SupplySolid-state hydrogen storage cartridge (rechargeable with deionized water)
ComplianceGB 20950–2020, GB 20951–2020, GB 20952–2020, HJ 733–2014, GB 37822–2019, HJ 1230–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelVOCs-800P
Detection TargetNMHC (Non-Methane Hydrocarbons)
Detection Limit≤0.07 mg/m³
Response Time≤60 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelEPM-100
Price RangeUSD 7,000 – 14,000 (FOB)
Measurement PrincipleBeta-ray Absorption (C-14 source)
Safety ClassificationNon-explosion-proof
Measurement Range0–20 mg/m³
Resolution0.1 µg/m³
Accuracy±20% (full scale)
Relative Error≤20%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHM-5000P
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelEAQM-100S
Price RangeUSD 7,000 – 14,000 (FOB)
Measured ParametersSO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀, Temperature, Relative Humidity, Wind Speed, Wind Direction, Atmospheric Pressure, TVOC
Measurement PrinciplesOptical Scattering (PM), Electrochemical Sensors (CO, NO₂, SO₂, O₃), Photoionization Detection (TVOC), Capacitive/Thermal Hygrometry & Thermistor-based Temperature Sensing, Ultrasonic Anemometry (Wind), Piezoresistive Barometry
CalibrationDual-mode (Automated Zero/Span Drift Compensation + Manual Field Calibration via Remote Command)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelEHM-X100
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelTVOC-800
Detection PrinciplePhotoionization Detection (PID)
Instrument TypePortable
Typical ConfigurationTVOC Analyzer
Detection Range0–20 / 200 / 1000 ppm (field-selectable)
Resolution≤10 ppb
Accuracy≤±10% of Full Scale
Response Time≤20 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelVOC-9000
Instrument TypePortable
Detection PrincipleInfrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs)
Target AnalytesVolatile Organic Compounds (VOCs), including but not limited to methane, propane, butane, benzene, toluene, xylene, and C2–C4 aliphatic/aromatic hydrocarbons
Detection RangeQuantitative leak rate from 0.001 mL/s to >100 mL/s (per ISO 21876:2022 Annex B reference methodology)
Thermal Sensitivity (NETD)≤0.01 °C @ 30 °C
Spatial Resolution≤1.3 mrad (with 24° lens)
Minimum Detectable Leak Rate≤0.001 mL/s (as verified per HJ 733–2014 protocol using calibrated methane/propylene challenge gas)
Response Time<4 s (T90, per IEC 60079-29-1)
Operating Temperature Range–20 °C to +50 °C
Enclosure RatingIP54
Explosion ProtectionEx ic nC op is IIC T4 Gb / Ex ic nC op is IIIC T130°C Db (IEC 60079-0, -11, -15, -31)
Weight2.5 kg (including battery and standard lens)
Data StorageInternal SD card (up to 512 GB, FAT32 formatted), supporting synchronized thermal + visible image pairs and time-stamped video (.mp4, H.264)
Software CompatibilitySkyRay LDAR Pro v3.2 (Windows 10/11), supports ASTM D7039–23 compliant reporting, US EPA OOOOa audit-ready export, and GLP-compliant metadata logging (operator ID, GPS coordinates, timestamp, ambient conditions)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelWAOL2000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelHM3000P
PricingAvailable Upon Request
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detection Time<5 min (typical), as fast as 30 s
Detection Limits0.1–0.5 ppb (depending on element)
Upper Detection Range10–60 ppm
Electrode TypeDisposable or Reusable Screen-Printed Electrodes (SPE) / Mercury-Film Electrodes
Power SupplyRechargeable Li-ion battery (≥10 h continuous operation, ≥100 assays)
IP RatingIP67
DisplaySunlight-readable transflective LCD
Data Storage2000 measurement records
ConnectivityUSB 2.0, Bluetooth (optional thermal printer support)
SoftwarePC-based analytical suite with ASV method programming, polarogram visualization, calibration management, and audit-trail-enabled data export (CSV, PDF)
ComplianceEPA Methods 7063, 7472
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelEVOCs-2000
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Instrument TypeOnline Analytical System
Typical ConfigurationDual-Channel GC-Based VOC Analyzer (C₂–C₅ and C₆–C₁₂)
Measurement RangeQuantitative analysis of ≥57 speciated VOCs per HJ 1010–2018
ResolutionPeak resolution ≥1.0 for critical pairs — cyclopentane/isopentane, 2,3-dimethylpentane/2-methylhexane, and o-xylene/styrene
Accuracy±10% relative to certified reference standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHM-8000P
Instrument TypePortable
Detection MethodsAnodic Stripping Voltammetry (ASV) & Colorimetric Spectrophotometry
Supported Elements9 standard (expandable to 12)
Electrochemical Scan ModesLinear Sweep Voltammetry (LSV), Square Wave Voltammetry (SWV), Differential Pulse Voltammetry (DPV)
Operating SystemAndroid-based embedded OS
Display7-inch capacitive touchscreen
Data ConnectivityCloud synchronization, OTA firmware updates, wireless method library updates
ComplianceEPA Methods 7063, 7472
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable Gas Analyzer
ConfigurationTVOC Detection System
Detection PrincipleFlame Ionization Detection (FID) + Photoionization Detection (PID)
FID Range0–50,000 ppm
PID Range0–4,000 ppm
FID Resolution0.5 ppm
PID Resolution0.1 ppm
FID Accuracy±5% of reading or ±3 ppm (whichever is greater)
PID Accuracy<±5%
FID T90 Response Time≤3.5 s
PID T90 Response Time<3 s
Zero Recovery Time≤4 s
Battery Life≥10 h
H₂ Cylinder Capacity100 mL @ 20 MPa
H₂ Runtime>12 h (full charge)
Ignition SystemDual spark igniters
Displayed ParametersFlame temperature, battery level, pump power, H₂ pressure
CPUOcta-core Cortex-A53 (64-bit, 2.3 GHz)
Memory64 GB ROM + 4 GB RAM, expandable via 128 GB microSD
OSAndroid 9.0
ConnectivityUSB Type-C, Wi-Fi 802.11 a/b/g/n, Bluetooth 4.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelBIO3000
Price RangeUSD 14,000–42,500
Instrument TypePortable
Test OrganismBioluminescent Bacteria
Operating Temperature0–40 °C
Reagent Storage TemperatureRoom Temperature
Coefficient of Variation (Repeatability)<5%
Sample Throughput1 sample per run
Assay Time<25 min
Detection Range0–65,535 RLU
Inhibition Range0–100% (linear response 10–90%)
Spectral Sensitivity320–1100 nm
Power Supply220 V ±10%, 50 Hz
Weight450 g
Dimensions90 × 220 × 40 mm
IP RatingIP65
Battery Life>12 h continuous operation
Data Storage4 GB internal (expandable), >100,000 records
ConnectivityUSB, Bluetooth, Wi-Fi
Software PlatformAndroid-based embedded OS with guided workflow
Compatible Strains*Vibrio qinghaiensis* sp.-Q67, *Photobacterium phosphoreum*, or *Vibrio fischeri* (ISO 11348-3 compliant)
Bacterial Lyophilized Stock Stability12 months at –18 °C
Environmental Operating Conditions5–40 °C, 10–90% RH (at 25 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Detection PrincipleFlame Ionization Detection (FID)
ConfigurationTotal VOC Analyzer
Measurement Range0–500,000 ppm
Resolution0.5 ppm
Accuracy±0.5% of reading
Response Time (T90)3.6 s
ComplianceGB 37822–2019, HJ 733–2014
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelEPM-2050
Price RangeUSD 21,000 – 35,000 (FOB)
Measurement MethodBeta-ray Absorption (β-ray)
Measured ParametersPM₂.₅, PM₁₀, TSP
Radioisotope SourceCarbon-14 (¹⁴C), Activity ≤ 100 µCi
Detection Limit≤ 2 µg/m³ (24-hr avg)
Concentration Range0–1000 µg/m³ or 0–10,000 µg/m³
Resolution0.1 µg/m³
Accuracy≤ ±5% (24-hr avg)
Flow Rate16.67 L/min (±2% stability)
Measurement CycleAdjustable, ≤ 60 min
Parallelism≤ ±10%
Display IntervalDefault 1 hr, user-configurable
Operating Temp. (Analyzer)15–40 °C
Operating Humidity≤ 90% RH
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions (L×W×H)417 × 483 × 382 mm
Weight25 kg (analyzer), 7.5 kg (pump)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic Analytical Instrument
ModelEHM-X200
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM) & Direct Manufacturer
Regional ClassificationDomestic (PRC)
ModelHM-7000P
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelWM-3000P
Instrument TypePortable
Measurement PrincipleColorimetric Spectrophotometry (DAP/DPD-based for chlorine species
Measured ParametersFree Chlorine, Total Chlorine, Chemical Oxygen Demand (COD)
Measurement Range0.02–1000 mg/L
Accuracy≤ ±5% of reading
Repeatability≤ ±5% RSD
Resolution0.01 ppm
Limit of Detection0.01 ppm
Power SupplyTwo 1.5 V AA batteries (72 h continuous operation) or 220 VAC-to-3 VDC adapter
Data StorageInternal non-volatile memory with timestamped records (date, time, parameter ID, sample ID, result)
Ingress ProtectionIP41 (dust-protected, vertically dripping water resistant)
ComplianceDesigned to support ASTM D1253, ISO 7393-2 (chlorine), and ISO 6060 (COD) methodology alignment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCEMS-X100
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy±10%
Repeatability≤2%
Response TimeAs low as 5 minutes (dependent on flue gas conditions)
Long-term Stability≤5%
Measurable ElementsPb, Cu, Cd, Cr, Zn, Ni, and over 20 other heavy metals
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelEAD-100 Series
Price RangeUSD 1,400 – 7,000 (FOB)
Measurement PrincipleOptical Light Scattering
Measured ParametersPM₁₀, PM₂.₅
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCEMS-V100
Price RangeUSD 42,000–70,000 (FOB)
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Accuracy≤±5% F.S. (range >200 μmol/mol)
RepeatabilityRSD ≤3%
Response Time<5 min
Stability≤20% (emission standard ≥100 μmol/mol)
AnalytesTotal Hydrocarbons (THC), Methane (CH₄), Non-Methane Total Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes), Volatile Organic Compounds (VOCs)
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Detection Range0–50 / 500 / 5000 ppm (as CH₄, adjustable)
LOD0.05 ppm (0–50 ppm range)
Zero Drift±1% F.S. or 0.1 ppm
Span Drift±1% F.S. or 0.1 ppm
Analysis Cycle1 min (standard)
Sample Flow Rate600 mL/min (analysis)
Calibration IntervalUser-configurable (e.g., daily, weekly, monthly)
Output InterfaceModbus TCP, 4–20 mA, RS232, RS485
Operating Environment0–45 °C, <90% RH (non-condensing)
Storage−20–60 °C, <90% RH
Required GasesHigh-purity H₂, zero-air, N₂, CH₄ calibration gas
Power Supply220 V AC, 50/60 Hz, 1500 W
Enclosure19″ rack-mount industrial cabinet