| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Domestic (China-made) |
| Model | GC-MS 6800 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Mass Range | 1.5–1000 amu |
| Resolution | Unit Mass Resolution |
| Sensitivity | ≥30:1 S/N (RMS) for 1 pg Octafluoronaphthalene (OFN) at m/z 272 |
| Scan Speed | Up to 10,000 amu/s |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | ICP-MS 2000 Series |
| Mass Analyzer Type | Quadrupole Mass Spectrometer |
| Intended Use | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Meets or exceeds GB/T 35791–2018 (Chinese National Standard for ICP-MS Performance Verification) |
| Software Platform | Windows 2000/XP/Vista/7 (32-bit & 64-bit) Compatible Control System |
| Sample Introduction | Integrated Peltier-Cooled Glass Cyclonic Spray Chamber (–20 °C to +20 °C), One-Piece Quartz Concentric Torch, Open-Access Nebulizer Assembly |
| Vacuum Interface | Dual-Conical Interface with Removable Sampling Cone (1.1 mm orifice) and High-Salt/High-Sensitivity Skimmer Cone Options (0.75 mm standard) |
| Ion Optics | Asymmetrically Mounted Extraction & Deflection Lenses, ETP Dual-Mode Detector (Analog/Digital Switching), Computer-Controlled Auto-Tuning |
| Automation | 250-Position Autosampler (Ethernet-Controlled, Positioning Accuracy < 500 µm) |
| RF Generator | Solid-State Frequency-Tunable Generator with Cold Plasma Mode, Collision/Reaction Cell Mode, and Standard Mode Support |
| Collision/Reaction Cell | Hexapole-Based, H₂/He Mixed-Gas KED Mode Enabled |
| Detection Modes | Full-Scan, Peak-Hopping, Time-Resolved Analysis (TRA) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | POW-I |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole LC-MS |
| Mass Range | m/z 10–2000 amu |
| Sensitivity | ≥50:1 S/N (RMS) for 10 pg reserpine in ESI+ mode |
| Resolution | Unit mass resolution (peak width at 10% height: ≤0.7 amu) |
| Mass Accuracy | ≤±0.20 amu |
| Ionization Sources | ESI (standard), APCI & APPI (optional) |
| Polarity Switching Time | ≤20 ms (−10 kV to +10 kV) |
| Vacuum System | High-speed imported turbomolecular pump |
| Software | ChemAnalyst v3.x with 21 CFR Part 11 compliance modules, audit trail, user privilege management, and GLP/GMP-ready workflow support |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TDM3000-MS |
| Mass Range | m/z 10–2000 amu |
| Sensitivity | >0.4 pg (positive ion mode), >0.8 pg (negative ion mode) |
| Analyzer Type | Single Quadrupole |
| Application Domain | Therapeutic Drug Monitoring (TDM)–Specific Clinical Use |
| Sample Throughput | Up to 150 samples per day |
| Online Sample Cleanup | Integrated protein/ phospholipid/salt removal via dual-column extraction and valve-switching architecture |
| Extraction Column Lifetime | ≥2000 injections |
| Ionization Source | Electrospray Ionization (ESI) |
| Detection Mode | Quantitative and Qualitative Analysis of Small Organic Molecules in Human Serum |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | microTyper MS |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Mass Resolution | R ≥ 500 |
| Sensitivity | Signal-to-Noise Ratio ≥ 100 |
| Mass Stability | ≤ 800 ppm |
| Mass Accuracy | ≤ 500 ppm |
| Mass Range | > 16,000 u |
| Repeatability | ≤ 0.06% |
| Ion Source | Matrix-Assisted Laser Desorption/Ionization (MALDI) |
| Detector | Large-Area Microchannel Plate (MCP) |
| Laser | Long-Life Nitrogen UV Laser (1–60 Hz Tunable) |
| Acquisition Rate | Up to 3 GHz sampling rate |
| Vacuum System | 320 L/s Turbo Molecular Pump |
| Sample Target | 96-well Reusable Stainless Steel Plate with 6 QC Spots |
| Exhaust Treatment | Triple-Stage Sterilization Unit |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | UPY-6800 |
| Quotation | Upon Request |
| Mass Analyzer Type | Single Quadrupole |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Sample Introduction | Integrated Pyrolyzer Module (Thermal Desorption/Pyrolysis Interface) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Conventional Gas Chromatograph with Electronic Flow and Pressure Control (EFC/EPC) |
| Ion Source | Dual-Filament Electron Ionization (EI) Source |
| Mass Analyzer | 180 mm Rod-Length Quadrupole with Pre-Filter RF Compensation |
| Mass Range | 1.5–1000 amu |
| Resolution | Unit Mass Resolution (UMR) |
| Sensitivity | ≥30:1 S/N for 1 pg Octafluoronaphthalene (OFN) in Full Scan Mode |
| Scan Speed | 10,000 amu/s |
| Library | NIST2014 Mass Spectral Library (Standard) |
| Compliance | Designed to Support GLP/GMP Data Integrity Requirements (Audit Trail, User Authentication, Electronic Signatures Optional via Software Configuration) |