- All
- Favorite
- Popular
- Most rated
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | ICP2060T |
| Price Range | USD 70,000 – 100,000 |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | ICP 2060T (Petrochemical-Optimized) |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | 0.5–10 ppb |
| Precision (RSD) | ≤1.5% |
| Long-Term Stability (2 h) | ≤2.0% |
| Wavelength Range | 190–500 nm (with 3600 l/mm grating) |
| Optical Resolution | ≤0.008 nm |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 1–10 µg/L (ppb) for most elements |
| Precision (Short-Term) | RSD < 0.5% |
| Stability (2-hr) | RSD < 1.0% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | < 0.0068 nm @ 200 nm |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OES8000S |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | ≤0.001 wt% |
| Repeatability | ≤1.5% RSD |
| Stability | ≤1.2% RSD |
| Wavelength Range | 140–680 nm |
| Optical Resolution | 10 pm |
| Spectrometer Design | Paschen-Runge mounting with 400 mm Rowland circle diameter |
| Grating | 3600 lines/mm concave holographic grating |
| Detector | High-performance linear CMOS array |
| Excitation Source | Fully digital plasma spark source with HEPS (High-Energy Pre-Spark) technology |
| Analysis Time | <40 s per sample |
| Argon Consumption | Optimized low-flow gas system |
| Operating Temperature | 15–30 °C |
| Relative Humidity | ≤70% RH |
| Power Requirement | 220 V ±5%, 50 Hz, single-phase, ground resistance <1 Ω |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Domestic |
| Model | ICP-3000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limits | Zn 213.856 nm: 0.47 µg/L |
| Ni 231.604 nm | 1.73 µg/L |
| Mn 257.61 nm | 0.18 µg/L |
| Cr 267.716 nm | 1.18 µg/L |
| Cu 324.754 nm | 1.1 µg/L |
| Ba 445.403 nm | 0.1 µg/L |
| Precision (RSD) | <0.5% |
| Long-Term Stability (2 h RSD) | <1.0% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | 6.8 pm @ 200 nm |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | ICP 3200 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Power Supply | Frequency-Convertible RF Generator |
| Optical Configuration | Dual-View (Axial & Radial) Simultaneous Observation |
| Spectral Coverage | 165–900 nm |
| Detector | Back-Illuminated CCD with Deep Depletion Technology |
| Resolution | ≤0.007 nm at 200 nm |
| Wavelength Calibration | Automated 2D Spatial Mapping Algorithm |
| Software Compliance | Supports Audit Trail, User Access Levels, and Electronic Signature per FDA 21 CFR Part 11 Requirements |
Show next