BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
ModelICP2060T
Price RangeUSD 70,000 – 100,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Regional CategoryDomestic (China)
ModelICP 2060T (Petrochemical-Optimized)
Instrument TypeSequential Scanning ICP-OES
Detection Limit0.5–10 ppb
Precision (RSD)≤1.5%
Long-Term Stability (2 h)≤2.0%
Wavelength Range190–500 nm (with 3600 l/mm grating)
Optical Resolution≤0.008 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelAFS200T
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelAAS9000
Instrument TypeIntegrated Flame/GF AAS
MonochromatorCzerny-Turner with 1800 lines/mm grating, 230 nm blaze
Optical SystemDouble-beam
DetectorSolid-state CCD array
Background CorrectionD₂ lamp + Self-absorption (AAS)
Wavelength Range190–900 nm
Wavelength Accuracy±0.25 nm
Wavelength Repeatability< 0.05 nm
Spectral Bandwidth0.1/0.2/0.4/0.7/1.4 nm (auto-switchable)
Flame Cu Detection Limit< 0.006 µg/mL
GF Cd Detection Limit≤ 1.0 pg
Flame Cu Precision (RSD)< 0.8%
GF Cd Precision (RSD)≤ 2% (auto-injection), ≤ 5% (manual)
Temperature Control Range (GF)Room temp – 3000 °C
Max GF Ramp Rate3000 °C/s
Safety ComplianceIntegrated gas leak, flame status, cooling water flow, and graphite furnace temperature monitoring per IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Instrument TypeFull-Spectrum Simultaneous ICP-OES
Detection Limit1–10 µg/L (ppb) for most elements
Precision (Short-Term)RSD < 0.5%
Stability (2-hr)RSD < 1.0%
Wavelength Range165–900 nm
Optical Resolution< 0.0068 nm @ 200 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOES8000S
Price RangeUSD 28,000 – 70,000
Instrument TypeFull-Spectrum Direct-Reading
Detection Limit≤0.001 wt%
Repeatability≤1.5% RSD
Stability≤1.2% RSD
Wavelength Range140–680 nm
Optical Resolution10 pm
Spectrometer DesignPaschen-Runge mounting with 400 mm Rowland circle diameter
Grating3600 lines/mm concave holographic grating
DetectorHigh-performance linear CMOS array
Excitation SourceFully digital plasma spark source with HEPS (High-Energy Pre-Spark) technology
Analysis Time<40 s per sample
Argon ConsumptionOptimized low-flow gas system
Operating Temperature15–30 °C
Relative Humidity≤70% RH
Power Requirement220 V ±5%, 50 Hz, single-phase, ground resistance <1 Ω
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelLIBS8000
Instrument TypeHandheld
Weight1.9 kg
Display5.0-inch Touchscreen
IP RatingIP54
Laser Wavelength1064 nm
Plasma Temperature>10,000 K
Spatial Resolution<1 µm
Spectral RangeTypically 190–900 nm (standard configuration)
Language Support8 languages (English, Chinese, French, Italian, Spanish, German, Indonesian, Polish)
Data IntegrationMES/LIMS/ERP-compatible via Ethernet/USB/Wi-Fi
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
CategoryDomestic
ModelICP-3000
Instrument TypeFull-Spectrum Direct-Reading
Detection LimitsZn 213.856 nm: 0.47 µg/L
Ni 231.604 nm1.73 µg/L
Mn 257.61 nm0.18 µg/L
Cr 267.716 nm1.18 µg/L
Cu 324.754 nm1.1 µg/L
Ba 445.403 nm0.1 µg/L
Precision (RSD)<0.5%
Long-Term Stability (2 h RSD)<1.0%
Wavelength Range165–900 nm
Optical Resolution6.8 pm @ 200 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyray Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelAFS200
Instrument TypeDual-Channel Atomic Fluorescence Spectrometer
Element CoverageAs, Sb, Bi, Hg, Se, Te, Pb, Sn, Ge, Zn, Cd (11 elements)
Detection Limit (DL)As/Sb/Bi ≤ 0.01 ng/mL
Precision (RSD)≤ 1%
Linear Dynamic Range> 3 orders of magnitude
Gas ControlIntegrated solenoid valve manifold (AFS200N/P) or dual-channel Mass Flow Controller (MFC), resolution 1 mL/min (AFS200T/S)
Hydride GenerationDiscontinuous flow with dual peristaltic pumps (N/T) or sequential injection combined with peristaltic pump (P/S)
AtomizerShielded quartz tube with low-temperature flame ignition
Optical SystemNon-dispersive design with high-efficiency photomultiplier tube (PMT) detection
SoftwareProprietary Windows-based AFS workstation with GLP-compliant audit trail, auto-calibration, and report generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (PRC)
ModelICP 3200
Instrument TypeFull-Spectrum Direct-Reading ICP-OES
Power SupplyFrequency-Convertible RF Generator
Optical ConfigurationDual-View (Axial & Radial) Simultaneous Observation
Spectral Coverage165–900 nm
DetectorBack-Illuminated CCD with Deep Depletion Technology
Resolution≤0.007 nm at 200 nm
Wavelength CalibrationAutomated 2D Spatial Mapping Algorithm
Software ComplianceSupports Audit Trail, User Access Levels, and Electronic Signature per FDA 21 CFR Part 11 Requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSkyRay Instrument
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelAAS6000
Instrument TypeFlame Atomic Absorption Spectrometer
Wavelength Range190–900 nm
Spectral Bandwidth0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm (auto-switching)
Grating1800 lines/mm, blaze wavelength 230 nm
Wavelength Accuracy±0.25 nm
Wavelength Repeatability< 0.10 nm
Resolution< 0.3 nm
Characteristic Concentration (Cu)< 0.025 µg/mL per 1% absorption
Detection Limit (Cu)< 0.006 µg/mL
Precision (Cu)< 0.8% RSD
Baseline Stability0.003 Abs (static), 0.004 Abs (dynamic)
Background CorrectionD₂ lamp + Self-absorption (up to 1 A)