- All
- Favorite
- Popular
- Most rated
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | ICP2060T |
| Price Range | USD 70,000 – 100,000 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | GC5400 |
| Application Scope | General-purpose analytical chromatography |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | WDX400 |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VOC-2000 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | Total VOC (TVOC) Analyzer |
| Measurement Range | 0–40,000 ppm (isobutylene equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±10% of reading |
| Response Time (T90) | <4 seconds |
| Operating System | Android-based embedded OS |
| Display | 4-inch capacitive touchscreen |
| Compliance | HJ 1019–2019 (China Technical Guideline for Sampling VOCs in Soil and Groundwater) |
| Data Export | USB mass storage & wireless (Wi-Fi/Bluetooth) |
| Connectivity | Built-in Wi-Fi, Bluetooth 4.2, QR code sharing |
| Power | Rechargeable Li-ion battery (≥8 h typical operation) |
| Environmental Rating | IP54 |
| Weight | ≤420 g |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Domestic (China-made) |
| Model | GC-MS 6800 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Mass Range | 1.5–1000 amu |
| Resolution | Unit Mass Resolution |
| Sensitivity | ≥30:1 S/N (RMS) for 1 pg Octafluoronaphthalene (OFN) at m/z 272 |
| Scan Speed | Up to 10,000 amu/s |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | WDX200 |
| Pricing | Available Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | EDX 3200S PLUS |
| Configuration | Benchtop/Floor-standing |
| Industry Application | Energy & Petrochemicals |
| Energy Resolution | 125 eV |
| Detector | FAST-SDD |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | EDX3300S |
| Configuration | Benchtop/Floor-standing |
| Industry Application | Energy & Petrochemicals |
| Energy Resolution | 125 eV |
| Repeatability (RSD) | <5% |
| Detector | FAST-SDD (Silicon Drift Detector) |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | EXPLORER 9000 |
| Application | Handheld / Portable |
| Industry-Specific Use | Soil and Atmospheric Environmental Monitoring |
| Elemental Range | Mg (Z=12) to U (Z=92) |
| Concentration Range | 1 ppm to 99.99% |
| Energy Resolution | 125 eV |
| Repeatability | RSD ≤ 1% at concentrations >10× LOD |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EDX 4500A |
| Configuration | Benchtop/Floor-standing |
| Application Scope | General-purpose Inorganic Elemental Analysis |
| Automation | 23-position Automatic Sample Changer Integrated |
| Light Element Capability | Optimized for Na–Cl (Z = 11–17) via Intelligent Vacuum System |
| Regulatory Context | Compliant with ISO 8258 (control charting), ASTM E1621 (XRF for metals), and GB/T 176–2017 (cement analysis) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | ICP-MS 2000 Series |
| Mass Analyzer Type | Quadrupole Mass Spectrometer |
| Intended Use | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Meets or exceeds GB/T 35791–2018 (Chinese National Standard for ICP-MS Performance Verification) |
| Software Platform | Windows 2000/XP/Vista/7 (32-bit & 64-bit) Compatible Control System |
| Sample Introduction | Integrated Peltier-Cooled Glass Cyclonic Spray Chamber (–20 °C to +20 °C), One-Piece Quartz Concentric Torch, Open-Access Nebulizer Assembly |
| Vacuum Interface | Dual-Conical Interface with Removable Sampling Cone (1.1 mm orifice) and High-Salt/High-Sensitivity Skimmer Cone Options (0.75 mm standard) |
| Ion Optics | Asymmetrically Mounted Extraction & Deflection Lenses, ETP Dual-Mode Detector (Analog/Digital Switching), Computer-Controlled Auto-Tuning |
| Automation | 250-Position Autosampler (Ethernet-Controlled, Positioning Accuracy < 500 µm) |
| RF Generator | Solid-State Frequency-Tunable Generator with Cold Plasma Mode, Collision/Reaction Cell Mode, and Standard Mode Support |
| Collision/Reaction Cell | Hexapole-Based, H₂/He Mixed-Gas KED Mode Enabled |
| Detection Modes | Full-Scan, Peak-Hopping, Time-Resolved Analysis (TRA) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EVOCs-1000 |
| Pricing | Available Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | VOC-3800 |
| Detection Principle | Flame Ionization Detection (FID) & Photoionization Detection (PID) |
| Instrument Type | Portable |
| Configuration | Dual-sensor VOC Analyzer (FID + PID) |
| Response Time | FID: ≤3.5 s, PID: ≤3.5 s |
| Safety Certification | Intrinsically Safe (Ex ib IIB T4 Gb) |
| Hydrogen Supply | Solid-state hydrogen storage cartridge (rechargeable with deionized water) |
| Compliance | GB 20950–2020, GB 20951–2020, GB 20952–2020, HJ 733–2014, GB 37822–2019, HJ 1230–2021 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VOCs-800P |
| Detection Target | NMHC (Non-Methane Hydrocarbons) |
| Detection Limit | ≤0.07 mg/m³ |
| Response Time | ≤60 s |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EPM-100 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Measurement Principle | Beta-ray Absorption (C-14 source) |
| Safety Classification | Non-explosion-proof |
| Measurement Range | 0–20 mg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±20% (full scale) |
| Relative Error | ≤20% |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | EDX3600H |
| Form Factor | Benchtop / Floor-Standing |
| Application Scope | General-Purpose |
| Elemental Range | Na–U |
| Quantification Range | 0.1 ppm – 99.99 wt% |
| Energy Resolution | 125 eV (Mn Kα) |
| Repeatability | ≤0.05% RSD (for major elements >96 wt%) |
| Detector | FAST-SDD (Silicon Drift Detector) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic |
| Model | SEE100 |
| Configuration | Benchtop/Floor-standing |
| Application Domain | Soil & Atmospheric Environmental Monitoring |
| Elemental Range | S (16) to U (92) |
| Quantification Range | 0.1 ppm – 99.99% (matrix-dependent) |
| Energy Resolution | ≤125 eV at Mn Kα |
| Detector | FAST-SDD (Silicon Drift Detector) |
| Excitation Source | Adjustable X-ray Tube (5–55 kV, 50–1000 µA) |
| Measurement Time | 60–300 s per sample |
| Simultaneous Elements | ≥30 |
| Sample Forms | Solid, Powder, Slurry, Liquid |
| Compliance | HJ 780–2015, GBZ 115–2002, ISO 12847, ASTM D6388 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory Ion Chromatograph |
| Model | TIC-680 |
| Configuration | Benchtop Dual-Channel IC System with Electrolytic Eluent Generator and Multi-Detector Compatibility |
| Intended Use | General-purpose anion/cation analysis, speciation coupling (AFS/ICP/ICP-MS), and regulatory-compliant water testing per GB 5750.10–2023 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | POW-I |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-5000P |
| Pricing | Available Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EDX3600 |
| Form Factor | Benchtop/Floor-standing |
| Application Scope | General-purpose |
| Elemental Range | Na–U |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | 125 eV |
| Repeatability | 0.05% RSD (for major elements >96 wt%) |
| Detector | FAST-SDD |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | ICP 2060T (Petrochemical-Optimized) |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | 0.5–10 ppb |
| Precision (RSD) | ≤1.5% |
| Long-Term Stability (2 h) | ≤2.0% |
| Wavelength Range | 190–500 nm (with 3600 l/mm grating) |
| Optical Resolution | ≤0.008 nm |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Benchtop/Stand-Alone ED-XRF |
| Model | EDX1800B |
| Element Range | S (16) to U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | 125 eV (at Mn Kα) |
| Repeatability | ≤0.05% RSD (for major elements >96 wt%) |
| Detector | Si-PIN Semiconductor Detector |
| Dimensions (W×D×H) | 550 × 416 × 333 mm |
| Sample Chamber | 460 × 298 × 98 mm |
| Weight | 45 kg |
| Operating Temperature | 15–30 °C |
| Power Supply | AC 220 V ±5 V |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EDX3300S PLUS |
| Configuration | Benchtop / Floor-Standing |
| Instrument Class | Conventional ED-XRF |
| Industry-Specific Design | Energy & Petrochemical Applications |
| Measurement Principle | Monochromatic Side-Illumination ED-XRF |
Show next