Empowering Scientific Discovery

Jiasheng (Hong Kong) Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabPlant
OriginUnited Kingdom
ModelSD-Basic
Maximum Feed Rate1500 mL/h
Inlet Air Temperature RangeAmbient to 250 °C (standardly up to 200 °C, upgradeable)
Outlet Air Temperature RangeProgrammable, monitored in real time
Air Flow Rate70 m³/h (fixed)
Drying Residence Time1.0–2.0 s
Nozzle Orifice Diameter0.5 mm
Particle Size Distribution0.1–40 µm
Minimum Sample Volume20 mL
Heating Power3 kW
Dimensions (W×D×H)1100 × 500 × 500 mm
Weight60 kg
Electrical Supply220 V / 50 Hz
Pump CapacityUp to 32 mL/min (peristaltic)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDiosna
OriginGermany
ModelMiniLab
Sample TypeOrganic
Max. Batch Capacity3 L
Temperature Range<100 °C
Particle Size Range200 µm – 10 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabPlant
OriginUnited Kingdom
ModelSD-06
Max. Feed Rate32 mL/min
Inlet Temp. Range40–250 °C
Outlet Temp. ControlYes
Air Flow100–500 m³/h
Heating Power3 kW
Built-in Compressor2.0 m³/h @ 5 bar, up to 9 bar
Nozzle Diameter (Std.)0.5 mm
Particle Size Range0.1–40 µm
Drying Time1.0–2.0 s
Max. Throughput1.5 L/h (water), 2.0 L/h (organic solvents)
Dimensions (H×W×D)1110 × 825 × 600 mm
Weight80 kg
Voltage220 V / 50 Hz, 13 A
Material316L stainless steel frame, borosilicate glass drying chamber & cyclone
Solvent CompatibilityYes (with N₂ inerting option)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDiosna
OriginGermany
ModelP1-6
Maximum Batch Volume3 L
Temperature Range< 100 °C
Particle Size Range100–500 µm
Sample TypeOrganic
ComplianceGLP-aligned design, suitable for pharmaceutical development under ISO 22093 and ASTM E2500 guidance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabPlant
OriginUnited Kingdom
ModelSD-07AG
Maximum Feed Rate2000 mL/h (water equivalent)
Inlet Air Temperature RangeAmbient to 250 °C
Particle Size Output0.5 mm (typical median, adjustable via nozzle selection and process parameters)
Nozzle Orifice Options0.5 mm (standard), 0.7 mm, 1.0 mm, 2.0 mm
Air Flow Capacity500 m³/h
Heater Power4000 W
Pump Flow Range0–36 mL/min (peristaltic)
Chamber Diameter≥300 mm
Control Accuracy±1.0 °C
Integrated Oil-Free CompressorYes
Touchscreen InterfaceIndustrial IR Touch Panel with PLC-Based Control System
ComplianceDesigned for GMP-aligned laboratory environments
materials of construction304 stainless steel enclosure, 316 stainless steel & PTFE wetted parts