| Brand | Quadro |
|---|---|
| Origin | Canada |
| Model | U5 Comil |
| Motor | 0.55 kW (3/4 HP) |
| Max Speed | 6500 rpm |
| Throughput | 50 g/hr – 150+ kg/hr |
| PSD (D50) | 150–300 µm |
| PSD (D90) | 300–2000+ µm |
| Design | Gapless conical mill architecture |
| Operation Modes | Dry and wet milling, granulation sizing, deagglomeration |
| Compliance | Designed for GMP-compliant pharmaceutical manufacturing environments |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | SO-260 |
| Instrument Type | Seed Flowability Tester |
| Moisture Measurement Range | 0–100% (optional integrated moisture module) |
| Weighing Resolution | 0.1 g |
| Sample Mass Capacity | 0–100 g |
| Heating Temperature Range | Ambient to 80 °C |
| Frame Dimensions | 750 × 750 × 2000 mm |
| Funnel Capacity | 37 L |
| Cylindrical Accumulation Chamber Volume | 49 L |
| Chamber Diameter | 500 mm |
| Chamber Height | 250 mm |
| Standard Discharge Orifice | DN60 |
| Optional Orifice Adapter | DN50 |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 5–6 bar |
| Bulk Density Range | 0.5–0.85 kg/L |
| Maximum Particle Size | 6 mm |
| Brand | OPSEUS/OPSIS |
|---|---|
| Country of Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | 200 Series |
| Instrument Type | Electric Heating Digestion Instrument |
| Automation Level | Fully Automatic |
| Digestion Positions | 10 |
| Maximum Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Electrical Resistive Heating |
| Reagent Channels | 1 |
| Brand | Caleva |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MBS-250 Spheronizer |
| Pricing | Upon Request |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N. 14 |
| Coating Capacity | 2–14 t/h |
| Liquid Dosing Range | 0.3–2.6 mL/kg, 0.9–4.2 mL/kg, 2.7–6.3 mL/kg, 3.7–8.6 mL/kg |
| Dual-Liquid Capability | Yes |
| Compliance | JKI Federal Research Centre Certified |
| Construction | Stainless Steel Mixing Drum with Nylon-Brush Auger |
| Dosing Principle | Patented Niklas Metering System (Mechanical Seed Roller + Precision Liquid Metering Wheel) |
| Liquid Delivery | Centrifugal Pump with Overflow-Regulated Metering Trough and Recirculation Loop |
| Optional Features | Dust Extraction Unit, Cross-Flow Sieve, Compressed Air Interface (for Pneumatic Actuation), Dual-Bagging Nozzle Adapter (DN 150 mm) |
| Brand | MultiGel |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MC100 |
| Pricing | Upon Request |
| Brand | Caleva |
|---|---|
| Origin | United Kingdom |
| Model | MLS |
| Voltage | 230 V or 110 V |
| Touchscreen | 7-inch capacitive LCD |
| Data Interface | 2 × USB 3.0, 2 × USB 2.0 |
| Machine Weight | 34 kg |
| Dimensions (W × D × H) | 505 × 600 × 420 mm |
| Mixing Capacity | 15–40 g (30–80 mL) |
| Extrusion Capacity | 10–80 g |
| Spheronization Capacity | 10–80 g |
| Main Impeller Speed | 10–250 rpm |
| Extruder Screw Speed | 90–150 rpm |
| Spheronizer Disc Speed | 500–4500 rpm |
| Die Orifice Standard | Ø1.0 mm × 1.0 mm square |
| Optional Dies | Ø0.5–3.0 mm round, multi-lobed profiles, variable thickness |
| Standard Spheronization Disc | 3 × 3 mm cross-hatched |
| Temperature Monitoring | Ambient & process zone |
| Motor Load Monitoring | 0–100% real-time reporting |
| Microscopy | Integrated USB digital microscope |
| Compliance Support | GLP-aligned data integrity, audit-trail-ready operation |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | InfraCheck |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating-based, Non-scanning Array Detector |
| Wavelength Range | 730–1100 nm (primary) / 1400–2500 nm (extended, per spec sheet) |
| Wavelength Resolution | 0.5 nm |
| Sampling Interval | 1 s |
| Measurement Modes | Diffuse Reflectance & Transmission |
| Chemometrics Software | RIMP |
| Dimensions | 345 × 385 × 200 mm |
| Weight | 16 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 30 W |
| Sample Volume | ~60 mL |
| Analysis Time | ~50 s |
| Sample Handling | Manual loading with rotating sample carousel |
| Interfaces | USB, Ethernet, Parallel Port |
| Environmental Protection | Dust- and moisture-resistant enclosure |
| Brand | OPIS / OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KD-200 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.05–240 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | RSD ≤ ±0.5% |
| Sample Weight Capacity | Solids ≤ 5 g, Liquids ≤ 20 mL |
| Recovery Rate | ≥ 99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 430 mm × 330 mm × 700 mm |
| Brand | OPISIS |
|---|---|
| Country of Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SX-110 |
| Quotation | Upon Request |
| Extraction Chamber Volume | 300 mL |
| Receiving Flask Volume | 230 mL |
| Temperature Range | 30–300 °C |
| Temperature Control Accuracy | ±1 °C |
| Number of Channels | 6 |
| Brand | SPG |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SPG Series |
| Pricing | Upon Request |
| Brand | Meridion |
|---|---|
| Origin | Germany |
| Model | LyoMotion LAB |
| Type | Dynamic Spray Freeze-Drying System (Rotating Drum Configuration) |
| Application | Laboratory-Scale Pharmaceutical & Biotech R&D |
| Vacuum Level | < 0.1 mbar |
| Condensation Capacity (24h) | < 5 kg |
| Chamber Volume | 0.3–2 L |
| Overall Dimensions | 790 × 2200 × 1990 mm |
| Weight | 950 kg |
| Power Supply | 230 V, 3 kW |
| Compressed Air Consumption | 5 m³/h @ 6 bar |
| Cooling Water Consumption | 5 L/min |
| Condenser Temperature | –75 °C |
| Drum Temperature Range | –50 °C to +50 °C |
| Control System | HMI-based PLC with Touchscreen Interface |
| Brand | OPSEUS/OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DI-310 |
| Instrument Type | Electric Block Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Temperature Range | Ambient to 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Electric Resistive Heating |
| Reagent Channels | 20 |
| Power Supply | 220 V / 50 Hz, 1200 W |
| Max. Overtemperature Protection | 500 °C (alarm + auto-hold) |
| Programmable Ramp Profiles | Yes |
| Digestion Time Range | 1–999 min |
| Integrated Lift Mechanism | Motorized Sample Rack Elevation/Depression |
| Sensor Diagnostics | Auto-detection, calibration status monitoring, and fault alerting |
| Compliance Standards | AOAC, EPA, DIN, ISO |
| Brand | SPG |
|---|---|
| Origin | Japan |
| Model | MN-125 |
| Maximum Operating Pressure | 0.3 MPa |
| Membrane Tube Diameter | φ10 mm |
| Total Length | 125 mm |
| Effective Membrane Length | 95 mm |
| Membrane Pore Size | 1 µm (customizable) |
| Membrane Material | SUS304 or SUS316 Stainless Steel |
| Sealing Material | FKM O-rings |
| Gas Inlet Connection | 6 mm OD tubing |
| Dimensions (W × D × H₁ × H₂) | 185 mm × 50 mm × 38 mm × (20–500 mm, adjustable stainless steel shaft length) |
| Optional accessories | secondary pressure regulators, stainless steel tubing, isolation valves, calibrated pressure transducers |
| Brand | Diosna |
|---|---|
| Origin | Germany |
| Model | SP-12-Plant |
| Control System | Siemens S7 PLC |
| Operating Software | Windows-based HMI with Excel integration |
| Mobility | Integrated mobile laboratory cabinet |
| Cleaning Options | Local washdown and CIP-capable |
| Temperature Sensing | PT-100 sensor embedded in stainless-steel mixing arm |
| Drive | Inverter-controlled motor |
| Scalability | Supports up to six SP-12 spiral mixers under centralized PLC control |
| Compliance | Designed for GLP-compliant food R&D environments |
| Brand | Meridion |
|---|---|
| Origin | Germany |
| Model | Continuous Spray Freeze-Drying System |
| Application | Laboratory-scale R&D to Pilot/Pharmaceutical Production (up to 20 kg/batch) |
| Vacuum Level | < 10 Pa (typical operating range for primary drying) |
| Condenser Capacity | ≥ 5 kg/24 h (standard configuration) |
| Overall Dimensions (L×W×H) | 2200 × 1800 × 2600 mm |
| Cooling Medium | Liquid nitrogen or closed-loop cryogenic refrigerant system |
| Particle Size Range | 200–800 µm (narrow distribution, CV < 15%) |
| Drying Time Reduction | Up to 50% vs. conventional shelf-based lyophilization |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/200 |
| Batch Capacity | 75–270 L |
| Throughput | 30 t/h |
| Control System | Integrated PLC with Weight & Time-Based Dosing |
| Liquid Dosing | Precision Metering Pumps + 20 L Weighing System |
| Powder Dosing | Synchronized Volumetric Feeders |
| Spray Nozzle | Fine-Mist Parabolic Distribution System |
| Compliance | Designed for ISO 9001-aligned seed treatment facilities, compatible with GLP/GMP documentation workflows |
| Brand | LabPlant |
|---|---|
| Origin | United Kingdom |
| Model | SD-Basic |
| Maximum Feed Rate | 1500 mL/h |
| Inlet Air Temperature Range | Ambient to 250 °C (standardly up to 200 °C, upgradeable) |
| Outlet Air Temperature Range | Programmable, monitored in real time |
| Air Flow Rate | 70 m³/h (fixed) |
| Drying Residence Time | 1.0–2.0 s |
| Nozzle Orifice Diameter | 0.5 mm |
| Particle Size Distribution | 0.1–40 µm |
| Minimum Sample Volume | 20 mL |
| Heating Power | 3 kW |
| Dimensions (W×D×H) | 1100 × 500 × 500 mm |
| Weight | 60 kg |
| Electrical Supply | 220 V / 50 Hz |
| Pump Capacity | Up to 32 mL/min (peristaltic) |
| Brand | VMI (France) |
|---|---|
| Origin | France |
| Model | Ultralab |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 998 × 447 × 430 mm |
| Processing Volume Range | 50–5000 mL |
| Main Rotor Speed | –50 to –5000 rpm |
| Auxiliary Agitator Speed | 10–250 rpm (bidirectional) |
| Power | 600 W |
| Weight | 70 kg |
| Jacket Pressure Rating | 0.5 bar (gauge) |
| Vessel Pressure Range | –0.96 to +0.4 bar (absolute) |
| Temperature Control | PT100 sensor integrated |
| Electrical Supply | Dual versions — 230 V / 50 Hz (Europlug F/G) or 110 V / 60 Hz (NEMA 5-15 B-type, 2 m cord) |
| Compliance Options | UL-certified variant available |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF12 |
| Active Area | 12 cm² |
| Piston Diameter | Ø100 mm |
| Mass | 6 kg |
| Max Contact Pressure | 2.5 N/mm² |
| Operating Temperature Range | −20 to 150 °C |
| Coolant–Cathode Outlet ΔT | ≤1 K at 5 A/cm² |
| Cooling/Heating Medium | External Liquid Circulator (not included) |
| Gas Inlet Fittings | Ø4 mm (fuel/air supply via Ø6 mm ports) |
| Electrical & Thermal Interface | Stainless Steel with Gold-Plated Contacts and FKM Seals |
| Actuation | Motorized 5/2 Solenoid Valve |
| Brand | FBF |
|---|---|
| Origin | Italy |
| Model | FBF7075 |
| Flow Rate | 8,000 L/h (fixed), variable via VFD option |
| Primary Homogenization Pressure | up to 250 bar (adjustable) |
| Secondary Homogenization Pressure | up to 50 bar (adjustable) |
| Maximum Sample Viscosity | 500 cP |
| Max. Inlet Particle Size | 500 µm |
| Max. Operating Temperature | 90 °C |
| Cleaning-in-Place (CIP) Time | 30 min |
| Sterilization-in-Place (SIP) Temperature | up to 145 °C |
| Cooling Water Requirement | 90–120 L/h at 2–6 bar |
| Main Motor | 75 kW, IP55 |
| Dimensions | 150 × 210 × 150 cm |
| Weight | 2500 kg |
| Power Supply | 380 V / 50 Hz |
| Brand | OPISIS |
|---|---|
| Origin | Sweden |
| Model | KD-200 |
| Instrument Type | Kjeldahl Distillation Unit |
| Automation Level | Semi-Automatic (Distillation Only) |
| Nitrogen Range | 0.05–240 mg N |
| Distillation Time | 2–4 min/sample |
| Repeatability | RSD ≤ ±0.5% |
| Sample Weight Capacity | ≤5 g (solid) or ≤20 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 430 mm × 330 mm × 700 mm |
| Weight | 30 kg |
| Brand | Diosna |
|---|---|
| Origin | Germany |
| Model | MiniLab XP |
| Batch Capacity | 50–1,000 g (expandable to 3 kg) |
| Inlet Air Temperature Range | Up to 100 °C (digital display) |
| Temperature Monitoring | Inlet & outlet air |
| Spray System | Dual-fluid high-pressure nozzle with adjustable atomization and fan-air pressure |
| Power Supply | 380 V / 50 Hz, 7.5 kW |
| Dimensions (W×D×H) | 1290 × 890 × 1100 mm |
| Weight | 200 kg |
| Construction | 316L stainless steel contact parts, 304 stainless steel non-contact structural components |
| Control System | Siemens PLC with HMI touchscreen interface |
| Compliance | Designed to support GMP, ISO 9001, and FDA 21 CFR Part 11–ready data integrity workflows |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | 300W PEM Fuel Cell Stack |
| Rated Power | 300 W (DC) |
| Output Voltage Range | 15–30 V DC |
| Nominal Current | 18 A |
| Operating Temperature | 5–55 °C |
| Electrical Efficiency | 45% @ 300 W |
| Fuel | 99.9% H₂ and ambient air |
| H₂ Consumption | 4.5 L/min (STP) |
| H₂ Inlet Pressure | 250–350 mbar(g) |
| Number of Cells | 30 |
| Cooling | Liquid-cooled |
| Interface | 1/4" internal thread (ISO 7/1) |
| Dimensions | 175 × 85 × 95 mm |
| Weight | 1.7 kg |