Empowering Scientific Discovery

Jiasheng (Hong Kong) Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPSEUS/OPSIS
Country of OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model Series200 Series
Instrument TypeElectric Heating Digestion Instrument
Automation LevelFully Automatic
Digestion Positions10
Maximum Heating Temperature450 °C
Temperature Control Accuracy±0.5 °C
Heating PrincipleElectrical Resistive Heating
Reagent Channels1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPSEUS/OPSIS
OriginSweden
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelDI-310
Instrument TypeElectric Block Digestion System
Automation LevelFully Automatic
Digestion Positions20
Temperature RangeAmbient to 450 °C
Temperature Control Accuracy±0.5 °C
Heating PrincipleElectric Resistive Heating
Reagent Channels20
Power Supply220 V / 50 Hz, 1200 W
Max. Overtemperature Protection500 °C (alarm + auto-hold)
Programmable Ramp ProfilesYes
Digestion Time Range1–999 min
Integrated Lift MechanismMotorized Sample Rack Elevation/Depression
Sensor DiagnosticsAuto-detection, calibration status monitoring, and fault alerting
Compliance StandardsAOAC, EPA, DIN, ISO
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDiosna
OriginGermany
ModelMiniLab XP
Batch Capacity50–1,000 g (expandable to 3 kg)
Inlet Air Temperature RangeUp to 100 °C (digital display)
Temperature MonitoringInlet & outlet air
Spray SystemDual-fluid high-pressure nozzle with adjustable atomization and fan-air pressure
Power Supply380 V / 50 Hz, 7.5 kW
Dimensions (W×D×H)1290 × 890 × 1100 mm
Weight200 kg
Construction316L stainless steel contact parts, 304 stainless steel non-contact structural components
Control SystemSiemens PLC with HMI touchscreen interface
ComplianceDesigned to support GMP, ISO 9001, and FDA 21 CFR Part 11–ready data integrity workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDiosna
OriginGermany
ModelMidiLab RC
Coating Drum Volumes7 L / 12 L / 20 L
Batch Capacity2.0–16.0 kg
Max Inlet Air Temperature100 °C (digital display)
Max Airflow250 m³/h
Power Supply380 V / 50 Hz, 24 kW
Dimensions (W×D×H)288 × 99 × 191 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPUS/OPSIS
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDI-110
Instrument TypeElectric Heating Digestion System
Automation LevelFully Automatic
Reagent Reservoir Capacity2 L
Construction MaterialsBorosilicate Glass Condenser & Vessel, Fluoroelastomer (FKM) Tubing
Vacuum SourceIntegrated Acid-Resistant Negative-Pressure Pump
FootprintCompact Design for Benchtop Integration Adjacent to Digestion Units
Control Interface6-Step Programmable Suction Profile
ComplianceDesigned for ASTM D3682, ISO 11733, and EPA Method 3050B-Compatible Sample Prep Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPSEUS/OPSIS
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDI-220
Instrument TypeElectric Heating Digestion System
Automation LevelFully Automatic
Digestion Positions20
Max. Heating Temperature450 °C
Temperature Control Accuracy±0.5 °C
Heating PrincipleResistive Electric Heating
Reagent Channels20
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPSEUS/OPSIS
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDI-320
Instrument TypeElectric Heating Digestion System
Automation LevelFully Automatic
Digestion Positions20
Max. Heating Temperature450 °C
Temperature Control Accuracy±0.5 °C
Heating PrincipleResistive Electric Heating
Reagent Channels20
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPSS/OPSIS
OriginSweden
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelDI-210
Instrument TypeElectric Heating Digestion System
Automation LevelSemi-Automatic
Digestion Positions10
Max Heating Temperature450 °C
Temperature Control Accuracy±0.5 °C
Heating PrincipleResistive Electric Heating
Reagent Channels10
Sample CapacityUp to 15 mL liquid or 5 g solid per tube
Programmable Step Duration0–999 min per stage
Continuous Operation24 h
InterfaceRS232 and USB
DisplayLCD with real-time temperature & timer
Safety FeaturesOver-Temperature Protection with Audible Alarm
Cooling ModeAuto-cooling post-digestion
Temperature SensorSelf-Calibrating Electronic Sensor
Language OptionsMulti-Language UI (English, German, French, Spanish, Chinese)
UpgradeabilityHardware and firmware upgradable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPSS/OPSIS
OriginSweden
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelDI-320
PricingUpon Request
Digestion Capacity20 samples per batch
Digestion Time<60 min
Temperature RangeAmbient to 450 °C (digital display)
Temperature Control Accuracy±0.5 °C
Over-Temperature Protection500 °C with audible/visual alert
Heating Duration Setting1–999 min
Power Supply220 V / 50 Hz, 2200 W
ComplianceAOAC, EPA, DIN, ISO