Karl Fischer Moisture Analyzer
Filter
Showing 211–217 of 217 results
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Coulometric (Electrolytic Iodine Generation) |
| Moisture Measurement Range | 3 µg – 100 mg H₂O |
| Measurement Accuracy | ±20% at 3 µg H₂O |
| Minimum Dispensing Volume | 1 µL |
| Resolution | 0.1 µg H₂O |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions (W×D×H) | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Environmental Operating Conditions | 20–30 °C, ≤85% RH |
| Compliance Standards | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automated Coulometric Titration |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 3 µg – 100 mg (H₂O) |
| Accuracy | ±3 µg (for 3–1,000 µg), ±0.3% (for >1 mg, excluding sample weighing error) |
| Minimum Dispensing Increment | 1 µL |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Interface | RS-232 for balance & PC connectivity |
| Printer | Integrated thermal printer |
| Operating Environment | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions (W×D×H) | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic Coulometric Titration |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 3 µg – 100 mg (H₂O) |
| Accuracy | < 0.3% RSD |
| Minimum Dispensing Increment | 1/2000 |
| Titration Control Precision | ±3 µg for 3–1000 µg |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Operating Temperature | 20–30 °C |
| Relative Humidity Limit | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions (W×D×H) | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | TimePower |
|---|---|
| Model | TP653 |
| Type | Coulometric Karl Fischer Titrator |
| Measurement Principle | Coulometric Titration (Karl Fischer) |
| Water Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±1% at 100 µg, ±0.5% above 100 µg (excluding sample handling error) |
| Electrolysis Current | 0–400 mA |
| Display | Backlit Chinese LCD |
| Data Storage | Internal non-volatile memory |
| Printer | Thermal printer (36-character Chinese/ASCII output) |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <200 W |
| Dimensions (W×D×H) | 310 × 315 × 215 mm |
| Weight | 3.5 kg |
| Enclosure | Corrosion-resistant engineering plastic |
| Compliance | GB/T 1600, GB 7600, GB/T 683, GB/T 11133, SH/T 0246, SH/T 0255 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | KF-4 |
| Titration Method | Fully Automatic Volumetric Titration |
| Principle | Volumetric Karl Fischer Titration |
| Moisture Range | 10 ppm to 100% H₂O |
| Resolution | 0.1 µL (volumetric) |
| Accuracy | ±0.01% (relative) |
| Minimum Dispensing Volume | 0.005 mL |
| Titration Precision | ±0.1% RSD |
| Stirring Control | Multi-stage Adjustable |
| Display | Large LCD with Real-time Process Monitoring |
| Data Storage | Internal Memory + RS-232/USB Output |
| Dimensions (W×D×H) | 260 × 330 × 170 mm |
| Weight | 3.0 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | Designed for GLP-compliant environments |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | ST-1523 |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 1 µg to 200 mg |
| Resolution | 0.1 µg |
| Accuracy | ±3 µg for 5–1000 µg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZKF-1 |
| Price | USD 2,850 (FOB Shanghai) |
| Measurement Principle | Volumetric Karl Fischer Titration |
| Water Content Range | 0.001–100 wt% |
| Resolution | 0.01 mL |
| Repeatability (RSD) | ≤0.01 |
| Linearity Correlation Coefficient | ≥0.998 |
| Burette Accuracy | ±0.004 mL |
| Electrode System | Dual Platinum Electrodes with Polarization Voltage Endpoint Detection |
| Reagent Compatibility | Pyridine-based or Pyridine-Free KF Reagents |
| Display | High-Brightness LED Numeric Display |
| System Architecture | Fully Enclosed Fluidic Pathway |
| Safety Features | Toxic Vapor Containment, Real-Time Error Interruption, Air Purge Functionality |