Karl Fischer Moisture Analyzer
Filter
Showing 1–30 of 220 results
| Brand | Aboni |
|---|---|
| Origin | Germany |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Sample Form | Solids, Powders, Films |
| Measuring Principle | Hydride-Generation Gas Evolution (CaH₂ Reaction) |
| Absolute Range | 0.2–30 mg H₂O |
| Relative Range | 0.0005–5 % w/w |
| Reproducibility | ±0.1 mg H₂O (at 1 mg), ±0.3 mg H₂O (at 20 mg) |
| Sample Weight | 0.01–50 g (up to 100 g, density-dependent) |
| Sample Volume | ~50 cm³ |
| Test Temperature | 50–210 °C (1 °C increments) |
| Ambient Air Monitoring | Temp (0.1 °C), RH (0.1 %), Pressure (1 mbar) |
| Reagent | Calcium Hydride (CaH₂) powder (~0.1 g/test) |
| Power Supply | 100/115/230 VAC |
| Dimensions | 285 × 170 × 250 mm (H×W×D) |
| Weight | 4.6 kg |
| Interface | Bidirectional RS-232 |
| PC Requirements | Windows® 98/ME/2000/NT/XP with RS-232 or USB (via adapter) |
| Compliance | ISO 15512 |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | ZSD-1 |
| Titration Method | Manual Volumetric Karl Fischer |
| Moisture Range | 0.02% – 100% |
| Resolution | 0.05 mL |
| Minimum Dispensing Increment | 0.1 mL |
| Polarization Voltage | −20 mV |
| Sensitivity | 1 × 10⁻⁶ A |
| Endpoint Delay | 10 ± 2 s |
| Titration Flow Rate | 0.1 mL/s |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 18 W |
| Display | LED digital (mL) |
| Endpoint Indication | Visual LED + audible buzzer |
| Stirring | Continuously variable speed motor |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | ZSD-2 |
| Titration Method | Fully Automated Volumetric Karl Fischer Titration |
| Moisture Range | 0.02% – 100% |
| Polarization Voltage | −20 mV |
| Sensitivity | 10⁻⁶ A |
| Endpoint Delay | 10 ± 2 s |
| Resolution | 0.01 mL |
| Titration Flow Rate | 0.01 mL/s |
| Display | LED Digital (mL) |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 18 W |
| Display Accuracy Error | ≤2% |
| [Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | ZSD-2J |
| Titration Method | Fully Automatic Volumetric Karl Fischer Titration |
| Measurement Principle | Volumetric Coulometric Dual-Mode (Volumetric Mode Standard) |
| Moisture Range | 0.01% – 100% (w/w) |
| Resolution | 0.01 mL |
| Accuracy | ≤2% RSD |
| Minimum Dispensing Volume | Auto-controlled by Precision Burette Drive |
| Endpoint Detection | Resistive (3 selectable thresholds: 500 Ω, 1.5 kΩ, 2 kΩ) |
| Endpoint Delay | Adjustable 10–300 s |
| Stirring Control | PWM-driven Stepless Speed Regulation |
| System Sealing | Closed-loop Reagent Handling with Auto Solvent Replacement & Waste Discharge |
| Display | High-Resolution Color LCD with Full Chinese GUI] |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQV-2200 |
| Pricing | Upon Request |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KF-1 |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 18 W |
| Operating Environment | 5–35 °C, <80% RH |
| Dimensions (L×W×H) | 345 × 245 × 140 mm |
| Measurement Range | 30 ppm to 100% w/w |
| Titration System | Standardized burette interface (interchangeable with common volumetric burettes) |
| Stirring | Electromagnetic, continuously variable speed control |
| Waste Disposal | Dry air pressure-assisted expulsion |
| Safety Design | Fully enclosed reaction system |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KF-1B |
| Measurement Range | 30 ppm to 100% (typical range: 0.03–90%) |
| Water Equivalence Precision | RSD ≤3% (using water standard) |
| Power Supply | AC 220 ± 22 V |
| Dimensions (W×D×H) | 335 × 260 × 130 mm |
| Weight | 6 kg |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KF-3 |
| Price | USD 2,780 (excl. VAT & shipping) |
| Measurement Principle | Volumetric Karl Fischer Titration |
| Water Range | 0.1–500 mg H₂O |
| Water Concentration Range | 10 ppm – 100% w/w |
| Burette Capacity | 20 mL |
| Minimum Dispensing Increment | 0.005 mL |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 225 × 290 × 210 mm |
| Net Weight | 3.0 kg |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MA-1 |
| Pricing | USD 4,200 (FOB Shanghai) |
| Titration Mode | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1 ppm |
| Moisture Content Range | 10 ppm – 100% (w/w) |
| Measurement Accuracy | ±0.001 mg H₂O |
| Minimum Dispensing Volume | 0.001 mL |
| Titration Control Precision | ±0.001 mL |
| Power Supply | 220 V AC, 50/60 Hz |
| Data Storage Capacity | 200 test records |
| Compliance | ISO 8533, ASTM E203, DIN EN ISO 12937, JIS Z 8831, GB/T 6283, USP <921> |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MA-10 |
| Pricing | USD 5,600 (FOB Shanghai) |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1 ppm (H₂O) |
| Moisture Range | 5 ppm – 100% (w/w) |
| Accuracy | ±0.0005 mL titrant |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | ±0.001 mL |
| Repeatability | ≤0.005% RSD |
| Linearity Correlation Coefficient | ≥0.999 |
| Burette Volume Accuracy | ±0.0002 mL |
| Relative Error | ≤0.2% |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 30 ppm – 100% (w/w H₂O) |
| Accuracy | ≤ ±0.002 mL |
| Minimum Dispensing Volume | 0.01 mL |
| Resolution | 0.01 mL |
| Repeatability | ≤ 0.01 mL |
| Linearity Correlation Coefficient | ≥ 0.998 |
| Burette Capacity | >25 mL |
| Detection Current Sensitivity | 10⁻⁶ A |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 30 ppm to 100% (typical working range: 0.03–90%) |
| Measurement Accuracy | ±0.3% RSD |
| Minimum Dispensing Volume | 0.01 mL |
| Power Supply | AC 220 V ± 10%, 50/60 Hz |
| Compliance | Designed for GLP-compliant environments |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Model | MA-2 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 10 µg H₂O |
| Moisture Range | 0.0001% (1 ppm) to 100% w/w |
| Accuracy | ±3 µg for 10–1000 µg H₂O |
| Titration Rate | Up to 0.6 mg/min |
| Electrolysis Current | Auto-controlled, up to 400 mA |
| Detection Threshold | 0.1 µg H₂O |
| Power Supply | AC 220 V ±10%, 50 Hz ±5 Hz |
| Operating Temperature | 5–40 °C |
| Display | LED digital readout |
| Compliance | ASTM D6304, ISO 760, USP <921>, EP 2.5.12, GB/T 7600, GB 6283, SH/T 0246, GB/T 11133, GB/T 11146, GB/T 18619.1, and other national & pharmacopoeial standards for coulometric KF titration |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Model | MA-2A |
| Instrument Type | Coulometric Karl Fischer Moisture Titrator |
| Moisture Range | 1 ppm to 100% (3 µg – 1000 mg H₂O) |
| Sensitivity Threshold | 0.1 µg H₂O |
| Accuracy | ±2 µg for 3–1000 µg H₂O |
| Electrolysis Current Output | 0–400 mA (auto-controlled) |
| Display | 240 × 64 dot-matrix LCD (blue backlight) |
| Readout Units | % w/w, µg H₂O |
| Minimum Sample Injection Volume | 0.001 mL |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 30 W |
| Operating Temperature | 5–40 °C |
| Operating Humidity | ≤85% RH |
| Dimensions | 300 × 250 × 100 mm (W × D × H) |
| Interface | RS-232 printer port |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Model | MA-2B |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 3 µg – 100 mg (equivalent to 3 ppm – 100% w/w, depending on sample mass) |
| Accuracy | ±2 µg (for 3–1 mg water), ±0.2% (for 1–100 mg water, excluding sampling error) |
| Sensitivity | 0.1 µg |
| Minimum Sample Delivery Resolution | 1/2000 |
| Display | 240 × 64 dot-matrix LCD (blue backlight) |
| Built-in Clock | Non-volatile real-time clock (year/month/day/week/hour/minute/second |
| Operating Environment | 0–50 °C, ≤85% RH |
| Power Consumption | 30 W |
| Dimensions | 300 × 250 × 100 mm |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Model | MA-3 |
| Instrument Type | Volumetric & Coulometric Karl Fischer Titrator |
| Moisture Range | 0.1 ppm to 100% (w/w) |
| Measurement Precision | ±0.1 µg for water mass ≤ 1 mg |
| Minimum Dispensing Resolution | 1/2000 of full stroke |
| Display | 7-inch color LCD touchscreen |
| Data Storage | Up to 999 test records with timestamp, sample ID, operator ID, and result export capability |
| Compliance | Fully aligned with GB/T 7600, GB 6283, SH/T 0246, SH/T 0255, GB/T 11133, GB/T 7380, GB 10670, GB/T 606, GB/T 8350, GB/T 8351, GB/T 3776.1, GB/T 6023, GB/T 3727, GB/T 7376, GB/T 18619.1, GB/T 512, GB/T 1600, GB/T 11146, GB/T 12717, GB/T 5074, GB/T 18826, and Chinese Pharmacopoeia (ChP) general chapter <0832> for Karl Fischer titration |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 ppm |
| Moisture Content Range | 0.00001% (0.1 ppm) to 100% |
| Measurement Accuracy | ±0.1 ppm |
| Minimum Dispensing Volume | 0.5 µL |
| Titration Control Precision | ±0.1 mV |
| Repeatability | ≤0.0002% RSD |
| Linearity Correlation Coefficient | ≥0.9999 |
| Power Consumption | <50 W |
| Operating Voltage | AC 220 V ±10%, 50 Hz |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤85% RH (non-condensing) |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Model | SKF-1(A) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100 wt% H₂O |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 0.0005 mL (1/2000 of 1 mL syringe) |
| Endpoint Detection | Dual Platinum Electrode Polarization Voltage Method |
| Resolution | 0.01 mL |
| Repeatability | ≤0.01 mL |
| Linearity Correlation Coefficient | ≥0.998 |
| Fluidic System | Fully Enclosed |
| Compatible Reagents | Standard Pyridine-Based or Pyridine-Free KF Reagents |
| Power Supply | 220 ± 22 V, 50 ± 1 Hz |
| Data Output | Integrated Thermal Printer (A-model only) |
| Rapid Titration Mode | Enabled |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CAT 7500 |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µA |
| Water Content Range | 1 ppm to 100% w/w |
| Accuracy | ≤0.05% |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Burette Control Precision | 0.15% |
| Display | 3.5″ 1/4 VGA TFT color screen (320 × 240 pixels) |
| Burette Options | 5 mL / 10 mL / 20 mL borosilicate glass (DURAN® 3.3), PTFE piston & valve |
| Electrode Interface | Dual platinum electrode (2 × 4 mm), polarization voltage adjustable 40–220 mV |
| Communication | 2 × USB-A, 1 × USB-B, 2 × RS232 |
| Dimensions (W×H×D) | 153 × 45 × 296 mm |
| Weight | 2.3 kg (host), 3.5 kg (complete system, excluding magnetic stirrer TM235KF) |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-2S |
| Titration Mode | Fully Automated |
| Method Type | Dual-Mode (Coulometric & Volumetric Karl Fischer) |
| Measurement Resolution | 0.01 μA |
| Water Content Range | 0.01 mg to 100% w/w |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | 0.1 μA |
| Drift Compensation | Automatic background drift correction (drift <5 µg H₂O/min) |
| Detection Limit | 0.01 mg H₂O |
| Sample Forms | Liquids, solids, gases, pastes |
| Display & Interface | Bilingual (Chinese/English) LCD with real-time titration curve visualization |
| Data Output | GLP/GMP-compliant report formats (%, ppm, mg), statistical analysis capability |
| Software | Embedded titration monitoring software with firmware upgrade support |
| Compliance | Designed for ISO 8533, ASTM E203, USP <921>, and EP 2.5.12 environments |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-3S |
| Titration Mode | Fully Automatic |
| Method Principle | Volumetric & Coulometric Karl Fischer Titration |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ±10 ppm |
| Minimum Dispensing Volume | 0.1 µL (1/20000 of burette volume) |
| Titration Control Precision | 0.1 µL |
| Polarization Voltage Output | 0–2550 mV (10 mV step, <±3% error) |
| Max Polarization Current | 5 mA |
| Current Range | 0–200 µA |
| Effective Current Accuracy | ±0.1 µA |
| Drift Compensation | Auto/manual background subtraction |
| Data Output Compliance | GLP/GMP-compliant reporting format |
| Interface | RS-232C (printer & PC connection) |
| Method Storage | 100 protocols |
| Optional | Dead-stop titration capability with accessory kit |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZDJ-600S |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ≤0.2% RSD |
| Minimum Dispensing Volume | 5 µL |
| Burette Precision | 1/20,000 |
| Burette Capacity | 10 mL (standard) |
| Burette Accuracy | ±10 µL @ 10 mL |
| Polarization Current Range | 0–200 µA |
| Polarization Voltage Range | 0–2550 mV |
| Polarization Voltage Step | 10 mV |
| Effective Current Accuracy | Better than ±0.1 µA |
| Repeatability (Pure Water) | <1% RSD |
| Standardization Repeatability | ±0.5% of mean across three consecutive runs |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T930 |
| Titration Method | Fully Automated Volumetric Karl Fischer |
| Moisture Range | 0.001–100% (recommended: 0.1–100%) |
| Polarization Current Range | 1–24 µA |
| Polarization Current Resolution | 0.01 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.0001 mL |
| Standard Burette Capacity | 5 mL (optional: 1 mL or 10 mL) |
| Burette Accuracy | ±0.01 mL (1 mL), ±0.01 mL (5 mL), ±0.02 mL (10 mL) |
| Drift Resolution | 0.1 µg/min |
| Dynamic Delivery Rate | 0.02 µL/s to 0.1 mL/s (auto-switching) |
| Sample Cell Volume | 120 mL |
| Stirring | Integrated Magnetic Stirrer (manual/automatic modes) |
| Display | 10-inch capacitive TFT touchscreen |
| Data Storage | 8 GB internal flash memory |
| Export Formats | Excel, PDF |
| Communication Interfaces | Wi-Fi, USB, RS-232, BNC |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Compliance | FDA 21 CFR Part 11 (audit trail, role-based access control, electronic signatures) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T931 |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 10 µg H₂O to 200 mg H₂O |
| Water Content Range | 0.0001%–100% (w/w) |
| Measurement Resolution | 0.001 µg H₂O (0.093 µg H₂O detection limit) |
| Current Resolution | 0.01 µA |
| Polarization Current Range | 1–24 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Electrolysis Current Options | 1, 2, 5, 10, 20, 50, 100, 200, 400 mA |
| Max. Electrolysis Rate | 37.34 µg H₂O/s (2240 µg H₂O/min) |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.001 mL |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Output Voltage | 24 V DC |
| Data Storage | 8 GB internal flash memory |
| Display | 10-inch capacitive TFT touchscreen (Android-based UI) |
| Compliance | FDA 21 CFR Part 11, audit trail, four-tier user permission system, electronic signature, data integrity controls |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | AQ-300 |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Dimensions (W × D) | 310 mm × 270 mm |
| Interface | Dual RS-232C ports |
| Compliance | Designed for ISO 8533, ASTM E203, and USP <921> moisture determination protocols |
| Software Integration | Compatible with PC-based data acquisition and GLP-compliant reporting systems |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | AQV-300 |
| Titration Method | Fully Automatic Volumetric Karl Fischer Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Dimensions (W × D) | 310 mm × 270 mm |
| Interface | Dual RS-232C ports |
| Compliance | Designed for GLP-compliant environments |
| Software Integration | Compatible with standard PC-based data acquisition and balance synchronization |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | MOICO-A19 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Display | 8.4-inch Color TFT Touchscreen with 16-Step Tilt Adjustment |
| Data Storage | USB Flash Drive Interface |
| Output | Built-in 58-mm Thermal Printer |
| Simultaneous Analysis | Up to 4 Independent Moisture Determinations |
| Stirrer Speed Control | 40 Adjustable Steps via LED Indication |
| Electrolytic Cell | Single-Chamber Coulometric Cell (No Catholyte or Diaphragm Required) |
| Status Indication | Tri-color LED + Dual-color Operation LED |
| Audio Guidance | Integrated Voice Prompt System |
| Blank Subtraction | Rapid Automatic Blank Compensation |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | MOIVO-A19 |
| Titration Method | Fully Automatic Volumetric Titration |
| Measurement Principle | Coulometric & Volumetric Karl Fischer (KF) Titration |
| Moisture Range | 10 ppm to 100% w/w |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Display | 8.4-inch Color TFT Touchscreen with 16-angle Adjustable LCD Mount |
| Data Interface | USB Host, LAN (Ethernet), Web-based Remote Access |
| Printer | Built-in Thermal Printer (58 mm paper width) |
| User Management | Password-protected User Authentication with Role-Based Access Control |
| Status Indication | Dual-color LED + Tri-color Status Lamp |
| Electrode/Stirrer | Motorized Stirrer with 40-step Adjustable Speed (LED Bar Graph Display) |
| Reagent Handling | Auto-Purge Function (1–99 cycles), Reagent Return (Refill & Recirculation) |
| Burette Head | Quick-release, Tool-free Burette Tip Assembly |
| Compliance | Designed for GLP/GMP environments |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 µL |
| Moisture Content Range | 0.001–100% w/w |
| Accuracy | ≤0.15% RSD |
| Minimum Dispensing Volume | 0.2 µL |
| Titration Control Precision | 1.0 µL |
| Electrode Configuration | Dual Platinum Electrode |
| Endpoint Detection | Bipotentiometric (Double-Pt) |
| Average Analysis Time | <3 min per sample |
| Data Storage Capacity | 10 method/sample records |
| Operating Ambient Humidity | ≤80% RH |
| Power Supply | 110–220 V AC, 50 Hz |
| Dimensions (L×W×H) | 320 × 240 × 410 mm |
| Net Weight | 5.5 kg |
| Auxiliary Functions | Titration Delay, Endpoint Hold Delay |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 1.0 µL |
| Moisture Range | 0.001–100% w/w |
| Accuracy (RSD) | ≤1.0% |
| Minimum Dispensing Volume | 5 µL (20 mL High-Precision Burette) |
| Repeatability | ±3.0% RSD |
| Linearity (r²) | ≥0.99 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Capacity | 20 mL |
| Titration Control Precision | ±5.0 µL |
| Power Supply | 110–240 V AC, 50–63 Hz |
| Data Storage | Internal Memory with Auto-Save Function |