| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-V1 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Titrator |
| Moisture Content Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Measurement Resolution | 1 ppm |
| Endpoint Detection Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Water Titration Calibration Curve | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Configuration | 20 mL Long-Life Automatic Burette |
| Burette Dispensing Accuracy | ±0.001 mL (with 20 mL high-precision burette) |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV (endpoint detection) |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Titration Response | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Burette Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Titrant Delivery Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Endpoint Detection Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Titration Response | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Burette Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity (r²) | ≥ 0.998 |
| Polarization Voltage Range | 0–120 mV |
| Burette | 20 mL long-life automatic burette |
| Titration Control Accuracy | 0.001 mL |
| Power Supply | 110–240 VAC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Acetic Acid-Optimized) |
| Titration Mode | Fully Automated |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Titration Control | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity framework |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Dual-Mode Capable) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric Option Support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Titration Control Accuracy | ±0.5 µL (20 mL burette) |
| Display | 7-inch color touchscreen (English/Chinese UI) |
| Compliance | GLP-compliant audit trail, 3-tier user permission system, FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Dedicated for Ibuprofen Capsules |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-level user access control, FDA 21 CFR Part 11 ready configuration |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AKF-V6 |
| Pricing | USD 6,800 (FOB Shanghai) |
| Titration Mode | Fully Automated Volumetric Titration |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Volumetric & Coulometric Capable via Optional Module) |
| Measurement Resolution | 0.1 ppm |
| Water Content Range | 10 ppm – 100% (0.001% – 100% H₂O) |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (with 20 mL burette) |
| Repeatability | ≤ 0.3% RSD |
| Linearity Correlation Coefficient | ≥ 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Control Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records (expandable via USB export) |
| Brand | HOGON |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm – 100% (0.001–100 wt% H₂O) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Repeatability | ±0.3% |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Sample Stirring Platform | Integrated magnetic stirrer with speed control |
| Electrode Configuration | Dual-platinum indicator electrode |
| Cell Design | Hermetically sealed titration cell with desiccant guard |
| Drift Compensation | Automatic enabled |
| Endpoint Hold Time | 10 s |
| Titration Delay | 5 s |
| Maximum Sample Volume | 50 mL |
| Maximum Titration Time | 30 min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric & Coulometric Karl Fischer Titrator |
| Moisture Range | 10 ppm – 100% (0.001–100 wt% H₂O) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Repeatability | ±0.3% |
| Linearity (R²) | 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 VAC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm to 100% (0.001–100% H₂O) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Repeatability | ±0.3% |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Lactose-Specific |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Precision | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Dual-Mode Capable) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data handling |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001% – 100% w/w) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant data handling, 21 CFR Part 11–ready audit trail, ISO/IEC 17025–aligned operation |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (Starch-Optimized Configuration) |
| Moisture Range | 10 ppm – 100% H₂O (0.001% – 100% w/w) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AKF-V6 (2020 Release) |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 ppm |
| Moisture Content Range | 10 ppm – 100% (0.001% – 100% H₂O) |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (with 20 mL burette) |
| Repeatability | ±0.3% |
| Linearity of Water Titration | R² ≥ 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Control Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Series Karl Fischer Online Moisture Analyzer |
| Pricing | Upon Request |
| Titration Mode | Fully Automated |
| Instrument Type | Coulometric & Volumetric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 1 ppm to 100% w/w water content |
| Measurement Resolution | Potentiometric: ±0.1 mV (−2000 to +2000 mV) |
| pH | ±0.001 pH (0–20 pH) |
| Photometric | ±0.003 Abs (0–1 Abs) |
| Titration Accuracy | Volumetric dosing precision ≤1 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 100 ppm – 100% w/w |
| Titration Resolution | 0.05 mL |
| Burette Capacity | 10 mL (user-supplied) |
| Electrode | Dual Platinum Electrode |
| Polarization Voltage | −40 mV |
| Current Sensitivity | 1 µA |
| Endpoint Detection | Amperometric (fixed-current threshold with 10–15 s delay) |
| Stirring | Built-in infinitely variable-speed electromagnetic stirrer |
| Valve System | 3-way solenoid-driven bidirectional valve |
| Tubing Material | Chemically resistant polymer |
| Operating Temperature | 5–35 °C |
| Relative Humidity Limit | ≤80% RH |
| Waste Disposal | Integrated automatic waste ejection system |
| Compliance | Designed for GLP-compliant environments |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-3140WSA |
| Pricing Range | USD 7,000–14,000 (FOB) |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Measurement Range | 1 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±2 µg for 3–1000 µg H₂O |
| Minimum Dispensed Volume | 1 µL (via syringe) |
| Electrolytic Current Output | 0–400 mA |
| Electrolysis Rate | 2.2 mg/min (37 µg/s) |
| Power Consumption | 50 W |
| Operating Voltage | 100–240 VAC, 50/60 Hz |
| Dimensions | 400 × 260 × 240 mm (L×W×H) |
| Weight | 2.0 kg |
| Data Storage | 500 timestamped records with searchable filters (date range, sample ID) |
| Connectivity | Standard USB 2.0, RJ-45 Ethernet port |
| Display | 800×480 color TFT-LCD touchscreen with bilingual (English/Chinese) UI |
| Stirring Speed | 5 adjustable levels |
| Safety & Diagnostics | Real-time electrode open/short circuit detection, blank current auto-compensation, endpoint drift correction, overcurrent/overheat protection |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-344 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer Accessory |
| Measurement Resolution | 0.005 mL |
| Moisture Range | 10 ppm to 100% H₂O |
| Burette Accuracy (10 mL) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Titration Control Precision | ±0.5% |
| Heating Method | Surround-type heating of titration cell |
| Temperature Range | Ambient to 60 °C |
| Temperature Stability | ±3 °C |
| Power Supply | AC 100 V, 50/60 Hz, ~55 W |
| Dimensions (W×D×H) | 100 × 150 × 133 mm |
| Weight | 1.8 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512 |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512S |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Volume | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz, ~600 W |
| Heating Temperature Range | 50–1000 °C |
| Evaporation Tube Material | Quartz |
| Sample Boat Material | Quartz |
| Sample Capacity | 10 mL |
| Dimensions | 835(W) × 340(D) × 345(H) mm |
| Weight | 18 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-513 |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg to 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Heating Temperature Range | Ambient to 200 °C |
| Evaporator Capacity | 100 mL |
| Evaporator Material | Transparent Heated Borosilicate Glass |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 210 × 330 mm |
| Weight | 6 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-611 |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric or Coulometric Karl Fischer Moisture Analyzer Compatible |
| Measurement Resolution | 0.1 µg |
| Moisture Content Range | 1 ppm to 100% |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 0–16 mL |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHK-501 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Sample Capacity | 24 positions |
| Heating Temperature Range | Ambient to 300 °C (individually programmable per sample) |
| Heater Type | Quartz Infrared Heater |
| Power Supply | AC 100–120 / 220–240 V, 50/60 Hz, ~100 W |
| Dimensions (W×D×H) | 452 × 400 × 362 mm |
| Weight | 20 kg |