Life Science Instruments
Filter
Showing 5851–5880 of 6354 results
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WUS22 |
| Temperature Range | 20–80 °C |
| Heating Power | 550 W |
| Ultrasonic Frequency | 37 kHz |
| Oscillation Mode | Reciprocating |
| Oscillation Amplitude | 20 mm |
| Oscillation Speed | 20–200 rpm |
| Speed Control Accuracy | ±1 rpm |
| Timer Range | 1–199 min |
| Bath Tray Dimensions (W×D×H) | 315×205×55 mm |
| External Dimensions (L×W×H) | 800×340×390 mm |
| Drain Valve | Integrated side-mounted |
| Display | TFT touchscreen with real-time simultaneous display of set temperature, oscillation speed, and timer |
| Brand | -- |
|---|---|
| Origin | Canada |
| Manufacturer Type | General Distributor |
| Import Status | Imported |
| Model | WinCELL |
| Pricing | Upon Request |
| Brand | Regent Instruments |
|---|---|
| Origin | Canada |
| Model | WinDENDRO Basic, Standard, Density Editions |
| Scanner Compatibility | STD 4800LA (4800 dpi), LA 2400 (2400 dpi) |
| Minimum Resolvable Feature Size | 0.005 mm (STD 4800LA), 0.011 mm (LA 2400) |
| Max Scan Area | 216 × 280 mm (STD 4800LA), 300 × 430 mm (LA 2400) |
| Image Formats Supported | TIFF, JPEG, JPEG2000, PNG, BMP |
| TWAIN Compliance | Yes |
| Gray Levels | Up to 16-bit (Density Edition only) |
| Color Channel Selection | Yes (Density Edition only) |
| Calibration Support | Reference-based spatial calibration from digital photographs |
| Software Architecture | Windows-native, CPU/GPU-accelerated image segmentation and ring detection algorithms |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WINDIAS Image Analysis System |
| Pricing | Available Upon Request |
| Maximum Scanning Area (Flatbed) | 400 × 370 mm |
| Maximum Scanning Area (Conveyor) | 250 × 290 mm |
| CCD Camera Resolution | 681 × 582 pixels |
| Area Measurement Accuracy | ≤4% |
| Frame Capture Rate | 1/25 s (50 Hz, real-time) |
| Software Image Resolution | 512 × 512 pixels, 24-bit color |
| Conveyor Speed Options | 60 / 100 / 140 / 190 mm/s |
| Max Conveyor Sample Width | 250 mm |
| Max Conveyor Sample Thickness | 5 mm |
| Camera Mount Height | 1150 mm |
| Flatbed Flattening Aid | Polypropylene sheet for curled leaf stabilization |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WinFOLIA |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WinRHIZO |
| Pricing | Upon Request |
| Optical Resolution | 4800 dpi (LC4800-II) / 2400 dpi (LA2400) |
| Scan Area (Roots & Needles) | 20 cm × 25 cm / 31 cm × 42 cm |
| Pixel Size | 0.008 mm × 0.008 mm (LC4800-II) / 0.011 mm × 0.011 mm (LA2400) |
| Optical Density Range | Up to 3.8 Dmax (LA2400 only) |
| Supported Image Formats | TIFF, JPEG |
| Software Editions | Basic, Standard, Professional |
| Brand | WIX |
|---|---|
| Origin | Shanghai, China |
| Model | WIX-autoPP Automated Western Blot Processing System |
| Throughput | Up to 24 membranes per run |
| Incubation Modules | 12 independently controlled modules |
| Temperature Control Range | 4–40 °C |
| Antibody Recovery Rate | ≥95% (up to 10 reuses) |
| Module Dimensions (optional) | 3×8 cm, 6×8 cm, or 9×8 cm |
| Membrane Wetting Maintenance | On-board wash buffer retention post-incubation |
| Fluidic Cross-Contamination Prevention | Automated in-line tubing rinse cycles |
| Compatibility | Open-platform design supports third-party primary/secondary antibodies and wash buffers |
| Brand | Workswell |
|---|---|
| Origin | Czech Republic |
| Model | WIC Infrared Thermal Imaging Camera for Animal Science |
| Resolution | 640 × 512 pixels |
| Thermal Sensitivity | 30 mK |
| Temperature Range | −25 °C to +150 °C (standard), optional up to +550 °C or +1500 °C with spectral filter |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz / 30 Hz |
| Spectral Band | 7.5–13.5 µm |
| Lens Options | 5°–69° FOV (9 mm–100 mm focal length) |
| Interface | USB 3.0 or GigE Vision compliant |
| IP Rating | IP65 |
| Software | WIRIS Suite with ROI analysis, multi-parameter environmental compensation, 14 color palettes, and time-synchronized imaging |
| Compliance | GenICam, USB3 Vision, IEEE 1588 Precision Time Protocol |
| Brand | Workswell |
|---|---|
| Origin | Czech Republic |
| Model | WIC Infrared Thermography Solution for Plant Science |
| Resolution | 640 × 512 pixels |
| Thermal Sensitivity | 0.03 °C (30 mK) |
| Temperature Range | −25 °C to +150 °C / −40 °C to +550 °C / up to +1500 °C with filter |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz |
| Spectral Band | 7.5–13.5 µm |
| Optional Lenses | 7.5 mm to 100 mm |
| Power Supply | USB 3.0 or PoE (GigE variant) |
| Interface | USB 3.0 or Gigabit Ethernet |
| Analog Video Output | PAL/NTSC (USB 3.0 variant) |
| SDK Support | Windows, Linux x86, Linux ARM, LabVIEW, MATLAB Simulink, Dewesoft |
| Calibration | NIST-traceable factory calibration available |
| Brand | WPI |
|---|---|
| Origin | USA |
| Model | EVOM2 |
| Power Supply | Rechargeable Battery (10 hr runtime) |
| Display | 4.5-digit LCD (1–9,999 Ω) |
| Electrode Interface | STX2 chopstick-style electrodes (4 mm wide × 1 mm thick) |
| Output | Isolated BNC analog output |
| Compliance | CE, RoHS |
| Cell Culture Compatibility | 6-, 12-, 24-, and 96-well Transwell®/HTS plates with permeable supports |
| Measurement Principle | AC-based four-electrode (2-current / 2-voltage) impedance spectroscopy at 12.5 Hz |
| Isolation | Galvanically isolated power architecture prevents electrode polarization, metal deposition, and tissue stimulation |
| Accessories Included | STX2 electrodes, calibration resistor, BNC cable, rechargeable battery pack, carrying case |
| Brand | WPI |
|---|---|
| Origin | USA |
| Model | EVOM AUTO |
| Electrode Configurations | 8-pair or 4-pair |
| Compatible Plates | 96-well and 24-well formats (MatTek, Millipore, Corning) |
| In-Cubator Design | Yes, CO₂-compatible |
| Cleaning Stations | 3 integrated stations (pre-, mid-, and post-measurement |
| Control Interface | Web-based software with collision protection algorithm |
| Data Transfer | Secure, encrypted cloud- and local-network-enabled transfer via dedicated mobile app |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanoliter2000 |
| Pricing | Upon Request |
| Brand | WPI |
|---|---|
| Origin | USA |
| Model | SYS-PV830 |
| Instrument Type | Automated |
| Reservoir Volume | 100 ms and 10 s pulse duration options |
| Pressure Control Modes | Positive pressure (injection), negative pressure (vacuum hold/suction), and maintenance pressure (anti-siphon bias) |
| Flow/Volume Range | 1–1000 pL per pulse (dependent on capillary geometry, pressure, and duration) |
| Pulse Duration Options | 100 ms and 10 s |
| Operating Pressure Range | 0–100 psi (adjustable in 0.1 psi increments) |
| Vacuum Range | 0–−25 psi |
| Compliance | ASTM F2149-01 (for microinjection system performance verification), ISO 13485 (design-controlled manufacturing environment), GLP-compliant data logging capability |
| Brand | WPI (World Precision Instruments) |
|---|---|
| Origin | USA |
| Model | SYS-PV840 |
| Type | Automated Microinjection & Electroporation System |
| Operating Pressure | Up to 87 PSI |
| Pulse Duration | 0.5 s |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultramicropump III |
| Pricing | Available Upon Request |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model No. | 106667 |
| Electrode Type | Combined ISE with Integrated Reference System |
| Measuring Ion | Fluoride (F⁻) |
| pH Range | 5–7 |
| Membrane Material | Lanthanum Fluoride (LaF₃) Crystal |
| DIN Standard Compliance | DIN 38404-7, DIN EN ISO 10304-1 |
| Output Signal | mV vs. Ag/AgCl reference |
| Temperature Range | 0–50 °C |
| Response Time | <2 min (t₉₀) |
| Detection Limit | ≤1 µg/L (0.05 µM) F⁻ |
| Storage Solution | 0.001 mol/L NaF or 10 g/L NaF standard solution |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Type | Ion-Selective Electrode (ISE) |
| Series | 500 (Half-Cell) and 800 (All-in-One Composite) |
| Connector Options | BNC or DIN |
| Measurement Range | Ion-specific, spanning from sub-ppb to saturated concentrations (e.g., F⁻: 0.02 mg/L to saturation |
| NH₄⁺ | 0.02–900 mg/L |
| NO₃⁻ | 0.4–62,000 mg/L) |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <781>, and EPA Method 9056A applications |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | OxiTop BOX |
| Temperature Range | 10–40 °C (±1 °C control accuracy) |
| Internal Volume | 180–500 L |
| Power Consumption | 160–380 W |
| Refrigerant | R-600a |
| Operating Ambient | 10–32 °C |
| Storage Ambient | −25–+50 °C |
| Transparent Glass Door | Yes |
| Internal Power Outlets | 1–4 (model-dependent) |
| Compliance | CE, IEC 61000-6-3/-6-4, EN 61326-1 (EMC & Safety) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | pH/ION 7320 |
| Display | Graphical monochrome LCD |
| Input Channels | Dual-channel (pH/ORP + ISE) |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.005 |
| ORP Range | ±1200.0 mV, ±2500 mV |
| ORP Accuracy | ±0.3 mV, ±1 mV |
| Ion Concentration Units | mg/L, mol/L, mg/kg, ppm, % |
| ISE Calibration | 2–7 points, linear & non-linear methods |
| Temperature Range | −5.0 to +105.0 °C |
| Temp. Accuracy | ±0.1 °C |
| CMC (Continuous Measurement Control) | Yes |
| Memory | 200 manual / 5000 automatic readings |
| Interface | Micro-USB |
| Power | Alkaline batteries or universal AC adapter |
| Dimensions | 190 × 240 × 80 mm (H × L × W) |
| Weight | 0.8 kg (1.0 kg with optional printer) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | SensoLyt 700IQ |
| Measuring Principle | Potentiometric pH/ORP with Built-in FET Pre-amplifier |
| Output | Digital IQ Interface (2-wire, power + data) |
| pH Range | 0.00–14.00 (electrode-dependent) |
| ORP Range | −2000 to +2000 mV |
| Temperature Measurement | NTC, −5 °C to +60 °C, ±0.5 K accuracy |
| Response Time (t₉₉) | <15 s |
| Pressure Rating | Up to 10 bar |
| IP Rating | IP68 |
| Materials | PVC sensor head, 316Ti stainless steel body |
| Cable Length Options | Via SACIQ-7.0 (order separately) |
| Compliance | EN 61326 Class B, FCC Class A, CE, cETLus |
| Lightning Protection | Integrated surge suppression |
| Calibration Modes | CAL TEC AUTO (auto-standard), CAL CON 2P, CAL CON 1P |
| Calibration Validation | Slope −50 to −62 mV/pH, Zero Offset −45 to +45 mV |
| Electrode Compatibility | SensoLyt SEA, SEA-HP, DWA, ECA, PtA |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | TS 608/2-i |
| Internal Capacity | 360 L |
| Temperature Range | 10–40 °C |
| Control Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Refrigerant | R-600a |
| Power Consumption | 160 W |
| External Dimensions (H×W×D) | 850 × 600 × 600 mm |
| Internal Dimensions (H×W×D) | 1452 × 470 × 440 mm |
| Net Weight | 34 kg |
| Internal Power Outlets | 2 × 230 V AC, 50 Hz |
| Transparent Double-Glazed Door | Yes |
| Compliance | IEC 61000-6-3, IEC 61000-6-2, EN 61326-1 (EMC for laboratory equipment), EN 61010-1 (Safety) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | TS 608/2-i |
| Air Circulation | Forced Convection |
| Control Method | Digital PID Temperature Control |
| Temperature Range | 10 °C to 40 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Capacity | 180 L |
| External Dimensions (H×W×D) | 850×600×600 mm |
| Refrigerant | R-600a |
| Operating Ambient Temperature | 10 °C to 32 °C |
| Storage Ambient Temperature | −10 °C to +50 °C |
| Power Consumption | 200 W |
| Net Weight | 34 kg |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Product Type | Imported Instrument |
| Model | Calypso II |
| Pricing | Available Upon Request |
| Brand | X-Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | X-Imaging HedylaX |
| Inoculation Modes | Solid-to-Liquid, Solid-to-Solid, Liquid-to-Solid, Liquid-to-Liquid |
| Colony Picking Accuracy | ≥98% (for colonies ≥1 mm in diameter) |
| Positioning Precision | ±0.15 mm (XY stage), ±0.05 mm (Z-axis) |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Smart Automated Cell Line Development System |
| Pricing | Available Upon Request |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Smart Automated Drug Screening System |
| Pricing | Upon Request |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Smart Mass Spectrometry Pre-analytical Automation System |
| Pricing | Available upon Request |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Smart Plasmid Construction and Extraction Automation System |
| Pricing | Available upon request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XD200-FL |
| Price | USD 6,300 (FOB Beijing) |
| Optical Design | Infinity-Corrected Optical System |
| Objective Mount | Quintuple Nosepiece |
| Eyepiece | Widefield WF10X (Field Number Φ22 mm) |
| Objective Lenses | Plan Achromatic PLL 10X/0.25 (WD 4.3 mm), 20X/0.40 (WD 8.0 mm), 40X/0.60 (WD 3.5 mm) |
| Fluorescence Excitation Bands | UV (330–400 nm), Violet (395–415 nm), Blue (420–485 nm), Green (460–550 nm) |
| Emission Filters | 425 nm, 455 nm, 515 nm, 590 nm |
| Light Sources | 100 W DC Mercury Arc Lamp (Fluorescence), 6 V/30 W Halogen Lamp (Transmitted Light) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment with Locking & Upper/Lower Limits |
| Fine Focus Graduation | 2 µm |
| Stage | Fixed Mechanical Stage (227 × 208 mm) |
| Condenser | Rotating Phase Contrast Annulus Condenser (WD 55 mm) |
| Eyepiece Tube | 45° Inclined, Interpupillary Distance 53–75 mm |