| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (PRC) |
| Model | XD20 |
| Instrument Type | Inverted Fluorescence Microscope |
| Optical System | CSIS Infinity-Corrected Achromatic Optics |
| Illumination | 6V30W Halogen Lamp (Pre-centered) |
| Objective Working Distance | Long Working Distance (LWD) |
| Phase Contrast Capability | Yes |
| Fluorescence Excitation | Standard Filter Cube Set (e.g., DAPI/FITC/TRITC) |
| Brand | CSR Biotech |
|---|---|
| Origin | Guangdong, China |
| Model | Cell Xtreme |
| Technology | Structured Illumination Microscopy (SIM) & Multi-Illumination Optical Diffraction Tomography (MI-ODT) |
| Resolution | XY: 60 nm, Z: 200 nm |
| Field of View | MI-ODT: up to 138 × 138 µm @100× |
| MI-SIM | up to 150 × 150 µm @100× |
| Imaging Speed | up to 25 fps @16-bit, 4608 × 4608 pixels |
| Eyepiece Options | Olympus IX85 / IX83 / Nikon Ti2-E |
| Objective | Apo 100×/1.5 Oil |
| Light Source | Multi-color coupled laser illumination system |
| Brand | CSY (Shenzhen Csys Instrument Manufacturing Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Instrument Type | Semi-Automatic Microbial Pathogen Detection System |
| Detection Throughput | 16-well |
| Sample Types | Solid, Liquid, Surface Swabs |
| Detection Mode | Qualitative and Semi-Quantitative |
| Display | 7-inch Capacitive Touchscreen |
| OS | Android 9.0 (2 GB RAM + 16 GB ROM, expandable to 128 GB via microSD) |
| Connectivity | 4G LTE (universal band), Wi-Fi 802.11 b/g/n, Ethernet, RS232, Dual USB (A & B), GPS Module |
| Data Export | USB export in TXT or Excel (.xlsx) format |
| Reporting | Built-in thermal label printer |
| Data Management | Cloud-ready architecture with platform interoperability (HTTP/HTTPS API compliant) |
| Regulatory Alignment | Designed to support GLP-compliant workflows and aligns with analytical requirements of GB 29921–2013, ISO 6579-1:2017, and AOAC Official Method 2012.06 for Salmonella detection in food matrices |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CT-1 |
| Outer Diameter | 2.0 mm |
| Inner Diameter | 0.9 mm |
| Material | Polytetrafluoroethylene (PTFE) |
| Length | 1 m (standard) |
| Compatible with | NARISHIGE Oil-Hydraulic Micromanipulators and Injection Holders |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | CT-4 |
| Material | 304 Stainless Steel (optional PTFE-lined) |
| Outer Diameter | 2.0 mm |
| Length per Coil | 1 m (standard) |
| Working Pressure | up to 20 MPa |
| Temperature Range | −20 °C to +150 °C |
| Surface Finish | Electropolished, Ra < 0.4 µm |
| Compliance | ISO 13485, RoHS, REACH, FDA-compliant variants available |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HT200 |
| Pricing | Upon Request |
| Brand | Curiox |
|---|---|
| Origin | South Korea |
| Model | HT2100 |
| Nozzle Flow Rate | 5–20 µL/s |
| Maximum Droplet Volume | 80 µL |
| Microplate Format | 96-well Laminar Wash Plate |
| Total Infusion Flow Rate | 300 mL/min |
| Dilution Factor per Wash Cycle | 3.5× |
| Brand | Curiox |
|---|---|
| Model | Pluto |
| Origin | Jiangsu, China |
| Instrument Type | Automated Liquid Handling & Cell Processing System |
| Plate Compatibility | Standard 96-well plates, 96-well deep-well plates |
| Intended Use | Research-grade flow cytometry sample preparation |
| Configuration Options | Three throughput tiers (Low/Medium/High) with modular accessory support |
| Regulatory Context | Designed for GLP-compliant research environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Germany |
| Model | CyBio FeliX |
| Pricing | Available upon Request |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | C100TB / C100TF |
| Detection Time | 60 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 50 µL / 100 µL |
| Throughput | 12 or 24 samples per run |
| Detectable Cell Diameter | 4–200 µm |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +3°C to 55°C (at 25°C ambient), ±0.1°C at 37°C |
| Temperature Uniformity | ±0.3°C at 37°C (25°C ambient) |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% at 5% CO₂ (37°C) |
| Dimensions | Cultiv8150 — Depth 560 mm × Width 540 mm × Height 580 mm |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | H120B |
| Detection Time | 60 s per sample |
| Cell Concentration Range | 1×10²–2×10⁷ cells/mL |
| Sample Volume | 50 µL or 100 µL |
| Throughput Options | 12-well or 24-well sample carousel |
| Detectable Cell Diameter | 1–80 µm |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RoboSep-16 |
| Sample Throughput | 16 samples per run |
| Compliance | ISO 13485-certified quality management system |
| Brand | CYSEA |
|---|---|
| Model | STEMvision™ |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CyteFinder II |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CyteFinder II |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Membrane Area Compatibility | 0.1–2.5 m² (cassette & hollow-fiber modules) |
| Predefined Process Programs | UF Production, Normalized Water Permeability (NWP), Clean-in-Place (CIP), Water Rinse, Alkaline Hold |
| Regulatory Alignment | Designed to support GMP, FDA 21 CFR Part 11, and EU Annex 11 compliance requirements |
| Software Architecture | Embedded control with audit trail, user access levels, and electronic signature capability |
| System Flexibility | Modular configuration for lab-scale development, pilot-scale process validation, and small-batch cGMP manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | Manufactured in China under Cytiva’s global quality system |
| Manufacturer Type | Authorized Distributor |
| Model | Agile flux TFF Systems |
| Pricing | Available upon request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 28-9308-42 |
| Application | Preparative Chromatography for Protein Purification |
| Flow Rate Range | Up to 25 mL/min |
| Max System Pressure | 20 MPa (200 bar) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| pH Measurement Range | 0–14, Accuracy ±0.1 pH (pH 2–12) |
| Temperature Monitoring Range | 0–99 °C, Accuracy ±1.5 °C (4–45 °C) |
| Fraction Collection Volume | 0.1–50 mL |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95%, non-condensing |
| Power Consumption | 1100 W |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA avant |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Detection Range | UV 190–700 nm |
| System Pressure Rating | Up to 20 MPa |
| Flow Rate Range | 0.001–20 mL/min (AKTA avant 25) |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| UV Absorbance Range | –6 to +6 AU |
| pH Measurement Range | 0–14 pH units (±0.1 pH accuracy, pH 2–12) |
| Temperature Control Range | 4–35 °C |
| Column Pressure Differential Monitoring | Dual integrated pressure sensors (pre- and post-column) |
| Buffer Preparation | Integrated BufferPro with quaternary valve, 26 preconfigured buffer recipes, real-time composition display |
| Software Platform | UNICORN 6 with FDA 21 CFR Part 11 compliance, audit trail, electronic signatures, role-based access control |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA avant |
| Flow Rate Options | 25 mL/min (AKTA avant 25) or 150 mL/min (AKTA avant 150) |
| Pressure Rating | Up to 20 MPa (200 bar) |
| Software | UNICORN 7.x or later |
| Column Tracking | RFID-enabled column recognition |
| Fraction Collector | Integrated Peltier-cooled (4–15 °C) |
| Buffer Preparation | BufferPro™ automated in-line mixing |
| Compliance | Supports 21 CFR Part 11-compliant configurations with audit trail, electronic signatures, and user access control |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA crossflow |
| Application Range | 25 mL – 50 L |
| Pump Flow Rate (Feed) | Up to 600 mL/min |
| Pump Flow Rate (Permeate/Retentate) | Up to 200 mL/min |
| Membrane Area Capacity | Up to 0.1 m² |
| Control Software | UNICORN™ v7.x or later |
| Compliance | FDA 21 CFR Part 11, USP <1211>, ISO 13485, GMP/GLP-ready |
| Sanitization | Validated NaOH (1 M) CIP, ≥6-log reduction in microbial challenge testing |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux 6 |
| Configuration | Semi-automated TFF platform |
| Application Scope | Concentration, diafiltration, cell harvest & clarification |
| Membrane Compatibility | Hollow-fiber modules & cassette-type membrane packs |
| Operating Volume Range | 50 mL – 6 L |
| Control Interface | Integrated touchscreen with real-time parameter monitoring |
| Data Logging | Onboard process recording (time-stamped, user-ID traceable) |
| Regulatory Support | Compliant with FDA 21 CFR Part 11 audit trail requirements for GMP-relevant workflows |
| Service Framework | OptiRun lifecycle support program |
| Change Notification | Web-based Change Control Notification (CCN) service |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux 6 |
| Application Scope | Process Development & Small-Scale Production |
| Control Mode | Automated Endpoint & Constant Retentate Volume (CRV) |
| Data Handling | Real-Time Logging with Audit-Trail-Capable Software |
| Regulatory Compliance | Designed for GMP Environments |
| Installation & Qualification | IQ/OQ Support Available by Certified Engineers |
| User Interface | Integrated Touchscreen HMI |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA flux |
| Application Scope | Research, Filter Screening, Process Development, and Small-Scale Production |
| Control Mode | Semi-Automated with Endpoint & Constant Retentate Volume (CRV) Control |
| User Interface | Touchscreen HMI with Real-Time Process Monitoring & Data Logging |
| Membrane Compatibility | Hollow-Fiber Modules and Cassettes |
| Regulatory Support | IQ/OQ Documentation Available via Fast Trak Validation™ Service |
| Compliance Context | Designed to support GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux s |
| Application Scope | Research & Membrane Screening |
| Control Mode | Automated Endpoint Control, Constant Retentate Volume (CRV) Mode |
| User Interface | 7-inch High-Resolution Touchscreen with Real-Time Process Monitoring |
| Data Handling | Onboard Logging (CSV Export), Audit-Trail-Ready Event History |
| Compliance Context | Designed for GLP-compliant workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA go Protein Purification System |
| Flow Rate | 0.01–25 mL/min |
| Max Operating Pressure | 5 MPa |
| UV Wavelength | 280 nm |
| Conductivity Range | 0.01–999.99 mS/cm |
| pH Range (optional) | 0–14 |
| Path Length (flow cell) | 2 mm (optional 5 mm) |
| Dimensions (W×D×H) | 335 × 464 × 482 mm |
| Weight | 27 kg |
| Power Consumption (typical) | 100 W |
| Safety Certifications | 2006/42/EC (MD), 2004/108/EC (EMC), 1999/5/EC (R&TTE) |
| IP Rating | IP21 |
| Tubing ID | 0.5 mm |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA go |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | LED-based UV Monitor |
| Detection Wavelength | 280 nm |
| Pump Type | Precision Plunger Pump |
| Flow Rate Range | 0.01–25.00 mL/min |
| Pressure Range | 0–5 MPa (50 bar) |
| UV Cell Path Length | 2 mm (standard) or 5 mm |
| UV Absorbance Range | –6 to +6 AU |
| Conductivity Range | 0.01–999.99 mS/cm |
| Temperature Monitoring Range | 0–70 °C |
| Gradient Accuracy | ±2% B (2–98% B, 0.5–20 mL/min, 0.7–2 cP) |
| System Footprint | 335 × 464 mm |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA oligosynt™ |
| Price Range | USD 14,000 – 140,000 (est.) |
| Principle | Electrochemical Phosphoramidite Synthesis |
| Type | High-Throughput Benchtop Synthesizer |
| Synthesis Scale | 10 µmol – 12 mmol |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pcc |
| Application | Periodic Counter-Current Chromatography (PCC) for Protein Purification |
| Software | UNICORN™ Control Software |
| Configuration Options | 3-Column (3C) or 4-Column (4C) Setup |
| Regulatory Support | Change Control Notification (CCN) Service |
| Service Offering | OptiRun™ Lifecycle Support Program |
| Compliance Context | Designed for GMP-aligned process development and scale-up per ICH Q5, Q8, and Q9 principles |