Mass Spectrometry Instruments
Filter
Showing 271–300 of 487 results
| Brand | Reilap |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Novisar Apply Series |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Triple Quadrupole |
| Application Scope | Specialized |
| Mass Range | 5–2000 amu (extendable to 5–2200 amu) |
| Sensitivity | (1) ESI+, MRM mode: 1 pg reserpine, S/N ≥ 1,200,000:1 (up to 2,000,000:1) |
| (2) ESI−, MRM mode | 1 pg chloramphenicol, S/N ≥ 1,200,000:1 (up to 2,000,000:1) |
| Resolution | 0.4–2 amu |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | ROXY™ EC |
| Application | Online Electrochemical Cell for LC-MS Coupling |
| Compatibility | Universal MS Interface (Agilent, Thermo Fisher, Waters, SCIEX, Shimadzu) |
| Configuration | Flow-through electrochemical flow cell with integrated electrode cartridge and MS-compatible solvent handling |
| Regulatory Context | Designed for GLP-compliant metabolic stability screening and oxidative stress simulation studies |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX 7500+ System |
| Instrument Type | Triple Quadrupole (Tandem Quadrupole, QqQ) |
| Application Scope | Universal LC-MS/MS Analysis |
| MRM Transition Rate | 800 transitions/sec |
| Vacuum System Compatibility | Dry Pump Compatible |
| Regulatory Alignment | Designed for GLP/GMP-compliant laboratories |
| Software Platform | SCIEX OS |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Tandem Quadrupole Mass Spectrometer |
| Configuration | Acoustic Droplet Ejection (ADE) Coupled to Triple Quadrupole MS |
| Regulatory Design | Designed for GLP/GMP-Compliant Quantitative Bioanalysis |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail and Electronic Signatures |
| Throughput | Up to 3 samples per second |
| Workflow Integration | Direct ADE-to-MS Interface Without Chromatographic Separation |
| Application Focus | High-Throughput Quantitative Screening in Drug Discovery, ADME, and Clinical Biomarker Analysis |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Echo™ MS System |
| Pricing | Upon Request |
| Application Scope | General-Purpose High-Throughput Quantitative Analysis |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Echo™ MS+ System |
| Configuration Options | Integrated with SCIEX Triple Quad™ 6500+ System or ZenoTOF™ 7600 System |
| Sample Introduction Method | Contactless Acoustic Droplet Ejection (ADE) |
| Throughput | Up to 1 sample per second |
| Compatibility | Standard 384-well and 1536-well microplates |
| Interface | Orthogonal Probe Ionization (OPI) Source |
| Regulatory Alignment | Designed for GLP/GMP-compliant workflows |
| Software Platform | SCIEX OS v2.4 or later |
| Brand | SCIEX |
|---|---|
| Origin | Singapore |
| Instrument Type | Tandem Quadrupole (Triple Quad™) or QTRAP® Mass Spectrometer |
| Flow Rate Range | 1–200 µL/min |
| Ion Source | OptiFlow™ Turbo V with Integrated Column Heater (up to 90 °C) |
| Spray Technology | SteadySpray™ Probe with Smart Probe Recognition |
| LC Platform | M5 Microflow LC featuring Microfluidic Flow Control™ |
| Column Compatibility | Phenomenex MicroFlow™ Columns |
| Software | SCIEX OS with MultiQuant™ MRMPilot™ and MasterView™ |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, ISO/IEC 17025-aligned workflows |
| Sample Introduction | Auto-sampler with vial-bottom sensing and jet-wash pump |
| Hardware Interface | Tool-free, hand-tight standard fittings with audible click confirmation |
| Gradient Delivery | Dual-pump architecture supporting direct injection and trap-elute modes |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP 4500 System |
| Category | Hybrid Triple Quadrupole / Linear Ion Trap Mass Spectrometer |
| Regulatory Status | Research-Use-Only (RUO), Not FDA-cleared or CE-IVD marked |
| Compliance | Designed for GLP/GMP-compliant laboratories |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP® 6500+ |
| Instrument Type | Hybrid Triple Quadrupole/Linear Ion Trap |
| Mass Range | Up to m/z 2,000 |
| Sensitivity | >10× improvement in detection sensitivity |
| Resolution | Unit mass resolution |
| Accurate Mass Capability | Not applicable (non-high-resolution platform) |
| Ionization Sources | IonDrive Turbo V, TurboIonSpray®, APCI, DuoSpray™, NanoSpray® III, SelexION®+ DMS, LDTD, LESA Clarity, Digital PicoView, NanoSource |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Triple Quad 6500+ |
| Instrument Type | Tandem Quadrupole (QqQ) LC-MS/MS System |
| Mass Range | 2000 m/z |
| Dynamic Range | 6 orders of magnitude |
| Polarity Switching Time | 5 ms |
| Scan Speed | 12,000 Da/sec |
| Ion Sources | IonDrive Turbo V, TurboIonSpray, APCI, DuoSpray, PhotoSpray, NanoSpray III, LDTD, LESA Clarity, Digital PicoView |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX Triple Quad 7500 LC-MS/MS System |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) Mass Spectrometer |
| Configuration | LC-MS/MS with QTRAP® Ready Architecture |
| Application Scope | Universal Quantitative and Qualitative Analysis in Life Sciences, Clinical Research, Environmental, Food Safety, and Forensic Laboratories |
| Regulatory Compliance | Designed for GLP/GMP-compliant environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Triple Quad™ 3500 |
| Configuration | ESI/APCI Turbo V™ Ion Source |
| Collision Cell | Curved LINAC™ |
| Regulatory Compliance | Designed for GLP/GMP and FDA 21 CFR Part 11–ready workflows (software-dependent) |
| Application Scope | Small-molecule quantitation in pharmaceutical, clinical research, forensic, food safety, and environmental laboratories |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Triple Quad™ 3500 |
| Instrument Type | Tandem Quadrupole Mass Spectrometer (QqQ) |
| Mass Range | 5–2000 Da |
| Ion Source | Turbo V™ Electrospray Ionization (ESI)/Atmospheric Pressure Chemical Ionization (APCI) Source |
| Collision Cell | Curved LINAC® Collision Cell |
| Ion Guide | QJet® Ion Guide |
| Front-End Optics | High-Pressure Q0 |
| Detection System | AcQuRate® Pulsed Counting Detector |
| Duty Cycle | Optimized for Fast LC and High-Throughput Quantitation |
| Regulatory Compliance Support | FDA 21 CFR Part 11, GLP/GMP Data Integrity Frameworks |
| Brand | SCIEX |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Triple Quad™ 5500+ System – QTRAP® Ready |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Mass Range | Not Specified |
| Sensitivity | Not Specified |
| Resolution | Not Specified |
| Mass Accuracy | Not Specified |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 5500+ System |
| Application Scope | General-Purpose Quantitative and Qualitative LC-MS/MS Analysis |
| Regulatory Status | Not Registered or Filed with NMPA for Clinical Diagnostics or Therapeutic Use |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | 6500+ System |
| Application Field | Universal |
| Mass Range (m/z) | Up to 2000 |
| MRM Scan Speed | Up to 12,000 Da/s |
| Polarity Switching Time | 5 ms |
| Linear Dynamic Range | 6 orders of magnitude |
| Ion Source | IonDrive™ Turbo V |
| Optional Technology | SelexION™+ Differential Mobility Spectrometry |
| Detection Mode | Triple Quadrupole + Linear Ion Trap (QTRAP®) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | 7500 |
| Instrument Type | Tandem Quadrupole (Triple Quad™) |
| Configuration | QTRAP®-Ready |
| Application Scope | Universal Quantitative and Qualitative Analysis |
| Flow Rate Compatibility | 1 µL/min to 3 mL/min |
| Polarity Switching Speed | <5 ms |
| Dynamic Range | 6 decades |
| Software Platform | SCIEX OS |
| Detector | High-Energy Electron Multiplier (HEM) |
| Regulatory Compliance | Designed for GLP/GMP, FDA 21 CFR Part 11–compliant workflows |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Time-of-Flight (TOF) Hybrid Quadrupole-TOF Mass Spectrometer |
| Model | TripleTOF 6600 |
| Resolution | 10,000 (FWHM at m/z 956) |
| Sensitivity | ≤10 amol β-galactosidase tryptic peptide (S/N ≥10) |
| Mass Accuracy | ≤10 ppm RMS (calibrated) |
| Mass Stability | ≤10 ppm over 24 h |
| Acquisition Rate | Up to 100 Hz MS/MS spectra |
| Linear Dynamic Range | 5 orders of magnitude |
| Q1 m/z Range | Up to 2250 Th |
| SWATH Window Flexibility | 2–25 Da variable width, up to 200 windows per cycle |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF® 5600+ |
| Mass Analyzer Type | Time-of-Flight (TOF) with Quadrupole Precursor Selection |
| Ion Source | Turbo V™ Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) |
| Additional Separation Technology | SelexION® Differential Ion Mobility Spectrometry (DIMS) |
| Data Acquisition Mode | SWATH® Acquisition (Data-Independent Acquisition, DIA) |
| Regulatory Compliance | Designed for 21 CFR Part 11–compliant environments |
| Application Focus | Quantitative and Qualitative LC-MS/MS in Drug Discovery, Proteomics, Metabolomics, and Impurity Profiling |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF® 6600 |
| Instrument Type | Quadrupole Time-of-Flight (QTOF) Mass Spectrometer |
| Ion Source | Turbo V™ Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) |
| Additional Technology | SelexION® Differential Ion Mobility Spectrometry (DIMS) |
| Data Acquisition Mode | SWATH® Acquisition (Data-Independent Acquisition, DIA) |
| LC Compatibility | Analytical-, Micro-, Nano-flow LC and Capillary Electrophoresis–Electrospray Ionization (CESI) |
| Brand | SCIEX |
|---|---|
| Origin | Singapore |
| Model | TripleTOF® 6600+ LC-MS/MS System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Category | Liquid Chromatography Tandem Mass Spectrometry System |
| Compliance | Designed for GLP/GMP, FDA 21 CFR Part 11–ready workflows |
| Software Platform | Analyst® TF 1.8 with SWATH® Acquisition support |
| Ion Source Flexibility | OptiFlow® Pro Micro/Nano ESI and SelexION® Differential Mobility Separation (DMS) compatible |
| Data Acquisition Mode | Data-Independent Acquisition (DIA) via SWATH® technology |
| Architecture | High-stability TOF ion optics with segmented ion entrance lens and windowed ionization control |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF™ 6600+ System |
| Category | Hybrid Quadrupole-Time-of-Flight Mass Spectrometer (Q-TOF MS) |
| Configuration | LC-MS/MS Platform for High-Resolution Accurate-Mass (HRAM) Analysis |
| Intended Use | Discovery and Quantitative Proteomics, Metabolomics, Lipidomics, and Small-Molecule Applications |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Configuration | Liquid Chromatography-Mass Spectrometry (LC-MS) Platform |
| Intended Use | Biopharmaceutical Characterization and Peptide Mapping |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500B QTOF System |
| Application Domain | Biopharmaceutical Characterization |
| Regulatory Status | Research-Use-Only (RUO), Not FDA-Cleared or CE-IVD Certified |
| Instrument Type | Quadrupole Time-of-Flight Liquid Chromatography Mass Spectrometer (LC-QTOF) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500R QTOF |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Configuration | LC-MS/MS Platform |
| Ion Source | Turbo V™ Ion Source (N-type ion path architecture) |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration, over 24 h) |
| Resolution | ≥ 35,000 FWHM (at m/z 622) |
| Mass Range | m/z 5–2,000 |
| Dynamic Range | > 5 orders of magnitude (linear) |
| Acquisition Modes | IDA, MRMHR, SWATH® Acquisition, MSᴱ, Full Scan + MS/MS |
| Software | SCIEX OS v2.4 or later |
| Compliance | Designed for GLP/GMP environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500R QTOF System |
| Application Domain | General-purpose LC-MS/MS Analysis |
| Compliance | Not registered as medical device in China |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX ZenoTOF 7600+ System |
| Instrument Type | Hybrid Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Broad-spectrum Proteomics, Biomarker Discovery, Translational Research, Clinical Assay Development |
| Acquisition Mode | ZT Scan DIA (Data-Independent Acquisition with Quadrupole Dimensionality), DDA, Targeted MS/MS |
| Scan Speed | Up to 640 Hz |
| Fragmentation Technology | Electron-Activated Dissociation (EAD) |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration) |
| Mass Resolution | > 35,000 FWHM (at m/z 200) |
| Dynamic Range | > 4 orders of magnitude |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX ZenoTOF 8600 System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Universal (Small Molecules to Intact Proteins) |
| Ion Source | OptiFlow Pro Turbo Ionization Source |
| Mass Analysis Technology | Zeno™ Trap-Enhanced TOF with High-Frequency Pulsed Injection |
| Max MS/MS Scan Rate | 858 Hz (dependent on mass range and acquisition mode) |
| Quadrupole Scanning Speed | up to 4000 Da/s |
| Fragmentation Modes | CID, EAD (Electron-Activated Dissociation) up to 50 eV in both positive and negative ion modes |
| Vacuum System | Oil-Free Dry Pumping |
| Software Platform | SCIEX OS 4.0 with Real-Time Performance Monitoring, Health Diagnostics & Auto-Tuning |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX ZenoTOF® 7600 System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Universal |
| Mass Range | >40,000 Da |
| Sensitivity Enhancement | 5–20× vs. prior-generation Q-TOF |
| Resolution | >42,000 (FWHM at m/z 1,222) |
| Mass Accuracy | <1 ppm (external calibration) |
| Pressure Range | 0–1024 bar (HPLC/UHPLC compatible) |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | 1–1200 m/z |
| Resolution | 0.7–4 amu (full width at half maximum, FWHM) |
| Detection Limit (IDL) | <1 fg (octafluoronaphthalene, OFN) |
| Scan Speed | ≥14,000 amu/sec |
| Oven Ramp Rate | ≥125 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Ion Source | High-Temperature Inert Dual-Filament Electron Ionization Source |
| Pre-filter | Dual-Axis Pre-quadrupole |
| Detector | Long-Life Extended-Dynamic-Range Electron Multiplier |
| Vacuum System | High-Capacity Turbomolecular Pump (≥300 L/s N₂) |
| Flow Control | Digital Electronic Flow Control (EFC) on All Inlets and Detectors |