Medical Instruments
Filter
Showing 151–180 of 254 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PELORIS II |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ST4020 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TP1020 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Macro SpinColumnTM |
| Pricing | Upon Request |
| Brand | MagnaBioSciences |
|---|---|
| Origin | USA |
| Model | ADS |
| Type | Research-Grade Magnetic Assay Development System |
| Detection Principle | Superparamagnetic Nanoparticle-Based Quantitative Immunoassay |
| Compatibility | Lateral Flow Assays (LFAs), Microfluidic Immunoassays |
| Read Time | ≤15 s per test strip (up to 6 detection zones) |
| Dynamic Range | 4-log linear quantification |
| Sample Matrix Tolerance | Whole blood, serum, plasma, food homogenates, wastewater, soil extracts |
| Regulatory Context | Designed for R&D use under GLP-compliant workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SYS-NVSL |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MASTER-SUR/NM |
| Pricing | Upon Request |
| Refractive Index Range (nD) | 1.3330–1.3660 |
| Urine Specific Gravity Scale | 1.000–1.060 (graduation: 0.001) |
| Serum Protein Scale | 0.0–12.0 g/100 mL (graduation: 0.2 g/100 mL) |
| Prism Material | Acid- and Salt-Resistant Resin |
| Dimensions | 3.2 × 3.4 × 20.3 cm |
| Weight | 105 g |
| Temperature Compensation | Manual only (no ATC) |
| Optional Accessory | RE-2391-50M Micro-sample Prism Cover |
| Consumable | RE-2391-59M Dedicated Daylight Plate |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MF-830 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MF200 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | OEM Supplier |
| Country of Origin | Lithuania |
| Model | MicrUs Pro |
| Spatial Resolution | 30 µm |
| Temporal Resolution | 7.5 ns |
| Gray Scale Levels | 16–256 |
| Time Gain Compensation (TGC) | Adjustable |
| Measurement Capabilities | Distance, Area, Perimeter, Angle, Volume, Stenosis Ratio, Time, Velocity, Heart Rate |
| Dynamic Range | 12 dB to 54 dB |
| Display Modes | B, B+B, 4B, B+M, M |
| Maximum Penetration Depth | 50 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ER-4000 VitalView Series |
| Quotation | Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiracleBox |
| Pricing | Available Upon Request |
| Temperature Range | 0°C to Ambient |
| Temperature Accuracy | ±1°C |
| Thawing Time (Bovine Serum) | ≤20 min |
| Cooling-to-Setpoint Time (Bovine Serum) | ≤12 min |
| Sample Compatibility | Standard Racks, Tube Holders, 96-Well Collection Plates |
| Control Method | Dry-Programmed Heating/Cooling |
| Interface | Touchscreen with Real-Time Sample Temperature Display |
| Multi-Zone Temperature Control | Yes |
| Modular Integration Capability | Yes |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FLIPR Penta |
| Pricing | Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Molecular Devices, Inc. |
| Product Category | Imported Laboratory Automation Equipment |
| Model | StakMax |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Multi-Equilibrium DIALYZERTM |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MyoVIEW II |
| Pricing | Available Upon Request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | MHW-3 |
| Coarse Movement Range (X/Y/Z) | 30 mm |
| Fine Movement Range (X/Y/Z) | 2 mm per full knob rotation |
| Minimum Graduation | 0.2 µm |
| Coarse Knob Travel per Full Rotation | ~4 mm |
| Fine Knob Travel per Full Rotation | 50 µm |
| Control Unit Dimensions | 115 × 115 × 132 mm, 1.6 kg |
| Drive Unit Dimensions | 155 × 155 × 100 mm, 0.9 kg |
| Hydraulic Tubing Length | 0.9 m |
| Included Accessories | B-9 Ball Joint, H-12 Electrode Holder, Allen Wrench |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EDUMR-I |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 15 mm |
| Effective Sample Volume | Ø12.5 mm × H25 mm |
| Image Linearity (x/y/z) | >90% |
| Spatial Resolution | <0.08 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | EDUMR-MRI |
| Type | Benchtop NMR Imaging System for Education |
| Magnet Field Strength | 0.5 T (Permanent Magnet) |
| Operating Frequency | ~21.3 MHz (¹H) |
| Gradient Strength | ≥15 G/cm |
| RF Coil Options | Standard 25 mm & 50 mm Diameter Surface Coils |
| Data Interface | USB 3.0 + Ethernet |
| Software Platform | EDU-Imaging Suite v4.x with DICOM Export, K-Space Access, and Pulse Sequence Editor |
| Compliance | CE Marked, Meets IEC 61000-6-3/6-4 EMI/EMC Requirements |
| Safety Class | Class I, EN 61010-1 |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-MRI |
| Pricing | Available Upon Request |
| Brand | Meiko Rikka |
|---|---|
| Origin | Japan |
| Model Numbers | 290CN, 290EA, 290CO, 290H2S, 290PQ, 290OP, 290PA |
| Detection Time | ≤60 s per test |
| Sample Volume | 10 mL whole blood |
| Sample Type | Human peripheral venous or capillary blood |
| Loading Mode | Semi-automatic manual insertion |
| Detection Limits | Malathion ≥0.004% (w/v), Dichlorvos ≥0.008% (w/v), Glufosinate ≥0.02% (w/v), Glyphosate ≥0.02% (w/v) |
| Regulatory Compliance | Designed per Japanese National Police Agency Forensic Guidelines (NPA-FG-2018), ISO 15197:2013 principles for qualitative point-of-care toxicant screening |
| Brand | Meiko Rikka |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 290CO |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | NR-16 |
| Pricing | Available Upon Request |
| Brand | Octadem |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | Octadem Biotech Co., Ltd. (Wuxi) |
| Model | ACR-2000 |
| Detection Principle | Transmission Turbidimetry & Photometric Quantification |
| Sample Throughput | 4 samples/12 min |
| Data Storage | Internal high-capacity memory with USB export |
| Calibration | Onboard QC calibration with traceable standards |
| Regulatory Compliance | Meets GB/T 26124–2010 (Clinical Chemistry Analyzers), aligned with CLSI EP15-A3 and ISO 15197:2013 for precision requirements |
| Intended Use | Quantitative determination of urinary albumin and creatinine to calculate UACR for early diabetic kidney disease (DKD) screening in primary care settings |
| Brand | Olympus |
|---|---|
| Country of Origin | Japan |
| Model | BF-1TQ290 |
| Insertion Tube Outer Diameter | 6.0 mm |
| Distal Tip Outer Diameter | 5.9 mm |
| Working Length | 600 mm |
| Field of View | 120° |
| Direction of View | Forward |
| Depth of Field | 2–100 mm |
| Instrument Channel ID | 3.0 mm |
| Minimum Focusing Distance | 3.0 mm from distal tip |
| Insertion Tube Rotation | ±120° |
| Compatible Light Source | Olympus CLV-290SL / CLV-290 |
| Compatible Video Processor | Olympus CV-290 |
| NBI (Narrow Band Imaging) | Yes |
| Range ID Function | Yes |
| Waterproof One-Touch Connector | Yes |
| High-Frequency Electrocautery Compatible | Yes |
| Laser Compatibility | Nd:YAG and 810 nm Diode Lasers |
| EBUS-Compatible | Yes |
| Reprocessing Compatibility | Fully compatible with Olympus ETD series cleaners/disinfectors and drying cabinets |
| Sterilization Compatibility | Ethylene Oxide (ETO) and Plasma Sterilization supported |
| Brand | Olympus |
|---|---|
| Country of Origin | Japan |
| Model | CV-170 + GIF-H170 + CF-H170L/i |
| Regulatory Clearance | China NMPA Import Registration No. 20152221796 (CV-170), 20143222972 (GIF-H170), 20143222973 (CF-H170L), 20143222945 (CF-H170i) |
| Power Input | 100–240 V AC, 50/60 Hz ±1 Hz |
| Dimensions (W×H×D) | 295 × 145 × 425 mm |
| Weight | 11.0 kg |
| Light Source | Integrated Long-Life LED |
| Video Output | HD-SDI, SD-SDI, DVI-D, RGB/YPbPr (1080i), Composite/Y/C (480i/576i) |
| Image Storage | MAJ-1925 Portable Memory (2 GB, TIFF/JPEG compression) |
| Compatibility | EVIS 100/130/140, OLYMPUS 150, EXERA 160, EXERA II 180, GI/BF/VISERA Series Endoscopes |
| Brand | OPTI |
|---|---|
| Origin | USA |
| Model | OPTI LION |
| Type | Dry-chemistry, Single-use Cartridge-based Electrolyte Analyzer |
| Measurement Parameters | pH, Na⁺, K⁺, Cl⁻, Ca²⁺ (including ionized calcium and standardized corrected calcium at pH 7.4) |
| Interface | Color Touchscreen with Multilingual Support (including English) |
| Barcode Scanner | Integrated |
| Quality Control | On-board QC with Statistical Analysis (Mean, SD, CV, Levey-Jennings charts) |
| Software | FDA 21 CFR Part 11–compliant firmware with Lifetime Free Updates |
| Regulatory Status | CE-IVD, FDA 510(k)-cleared |
| Compliance | Meets CLIA, ISO 15197, ISO 22870, and ASTM E2573 standards for point-of-care and core laboratory use |
| Brand | OPTI |
|---|---|
| Origin | USA |
| Model | OPTI R |
| Measurement Principles | Optical Fluorescence (pO₂), Severinghaus-type CO₂ Sensor (pCO₂), Potentiometric Ion-Selective Electrodes (pH, Na⁺, K⁺, Ca²⁺), Spectrophotometric Hemoglobin Detection (tHb, SO₂) |
| Sample Type | Whole blood (arterial, venous, capillary), heparinized |
| Test Time | ≤ 60 seconds per sample |
| Cartridge Capacity | 50 tests per single-use disposable cartridge |
| Onboard QC | Three-level automated quality control with integrated calibrators |
| Data Storage | 300 patient results + 60 days of QC records (3 levels) |
| Interface | Built-in barcode scanner, RS232/USB, LIS/HIS-compatible software |
| Display | 7-inch color touchscreen with intuitive graphical UI |
| Regulatory Compliance | FDA 510(k) cleared, CE IVD, ISO 13485 certified |
| Origin | USA |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | P3 |
| Pricing | Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Paragon XHD |
| Price Range | USD 0–140,000 (FOB) |
| Spatial Resolution | 80–100 µm |
| Temporal Resolution | 30 fps |
| Gray Scale | 256 levels |
| Time-Gain Compensation (TGC) | 8 adjustable segments |
| Measurement Functions | Distance, Circumference, Area, Volume, Depth, Angle |
| Dynamic Range | 30–150 dB |
| Display Modes | B-mode + Color Doppler + Pulsed-Wave Doppler (B+C+PW) |
| Maximum Penetration Depth | 50 mm |
