Medical Instruments
Filter
Showing 181–210 of 254 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ML880 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PowerLab |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | Multiple Standardized Sizes |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 630297 / 630299 |
| Pricing | Available Upon Request |
| Tubing Length (630297) | 25.4 cm (10 in) |
| Tubing Length (630299) | 76.2 cm (30 in) |
| Connection Type | One Male Luer Lock + One Female Luer Lock |
| Maximum Pressure Rating | 1000 psi |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Ultra-Micro / Micro / Macro ProtipTM |
| Pricing | Available Upon Request |
| Brand | Raymetech |
|---|---|
| Origin | Jiangsu, China |
| Model | MMS100 |
| Type | Fully Manual Mechanical Micromanipulator |
| Positioning Resolution | Sub-micrometer (typical manual fine-adjustment capability) |
| Mounting | Standard 36 mm dovetail or M4/M6 threaded base interface |
| Material | Anodized aluminum alloy with stainless steel precision screws |
| Load Capacity | ≤ 200 g (static, tip-mounted) |
| Degrees of Freedom | 3-axis orthogonal translation (X/Y/Z) with coarse + fine dual-scale control |
| Repeatability | ≤ ±1 µm (under stable environmental conditions) |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | IFFM-E |
| Pump Speed Range | 0–99 digital steps |
| Dilution Ratio | 1:99 |
| High-Voltage Input | −100 to −1000 V (stability < 0.01%) |
| Spectral Response Range | 300–650 nm (peak sensitivity at 420 nm) |
| Photomultiplier Gain | 1×, 2×, 4×, 8×, 16× |
| Filter Cutoff Frequency | 10–100 Hz |
| Sampling Rate | 1–100 samples/s |
| Analog Signal Input Range | 0–5 V |
| Software | REMEX Chemiluminescence Data Acquisition & Kinetic Analysis Suite (fully localized Chinese UI) |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-B |
| Key Components | Integrated Electrochemical Analyzer, Multifunctional Chemiluminescence Detector, CNC Capillary Electrophoresis High-Voltage Power Supply, Microfluidic Chip Multi-Channel HV Power Supply, Flow Injection Sampler, and PMT-Based Luminescence Detection Module |
| Dynamic Range | >5 decades |
| Electrochemical Potential Range | ±10 V |
| Current Range | ±250 mA |
| CE HV Output | 0–20 kV / 0–300 µA |
| Microfluidic HV Output | 0–2000 V per channel (4 or 8 channels) |
| PMT Operating Voltage | −100 to −1000 V |
| Spectral Response | 300–650 nm (peak @ 420 nm) |
| Sampling Rate | 1–200 Hz |
| Integration Time | 0.001–10 s |
| Filter Frequencies | 10/20/50/100 Hz |
| Input Impedance (Electrochemical) | 10 MΩ |
| Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-1 |
| Dynamic Range | >6 orders of magnitude |
| PMT High-Voltage Supply | −100 V to −1000 V (stability ≤0.05%, current ≥5 mA) |
| Amplifier Gains | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV (p-p, 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 300–650 nm (λₘₐₓ = 420 nm) |
| Radiant Sensitivity | >1000 A/lm |
| Software Features | Real-time zero calibration, auto-gain control, peak/area quantitation, ASCII data export, serial communication interface |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Medical Instrument |
| Model | JANUS G3 Blood iQ |
| Pricing | Available Upon Request |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240T |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | Roche |
|---|---|
| Origin | Switzerland |
| Model | Cedex Bio / Cedex Bio HT |
| Principle | Continuous Flow (Channel-Based) Analysis |
| Reagents | Roche-Approved Only |
| Sample Type | Cell Culture Supernatant |
| Analyte Scope | Substrates, Metabolites, Products |
| Throughput | High (Cedex Bio HT), Standard (Cedex Bio) |
| Regulatory Context | Designed for GMP-aligned bioprocess monitoring and QC release testing |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | MP-500 |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMS |
| Pricing | Upon Request |
| Brand | Scintomics |
|---|---|
| Origin | Germany |
| Model | GRP 2V–6V Modular System |
| Configuration | Fully modular (base module + up to 5 valve modules + up to 4 syringe-driven distribution modules) |
| Regulatory Design Basis | Compliant with GMP, ISO 13485, and applicable IEC 61010-1 safety standards for Class II medical device manufacturing environments |
| Software Architecture | Windows-based control interface with audit trail, user access levels, and electronic signature support per FDA 21 CFR Part 11 requirements |
| Radiation Shielding | Integrated lead–tungsten composite shielding (≥15 cm Pb-equivalent for 511 keV photons) |
| Operating Environment | Designed for hot cell integration (Class C cleanroom compatible, IP54-rated modules) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECG Catheter |
| Pricing | Available Upon Request |
| Catheter Material | Polyimide Tubing |
| Effective Length | 15 cm (6") |
| Sizes | 1.1F (0.37 mm) and 2F (0.64 mm) |
| Electrode Material | Platinum |
| Electrode Length | 0.25 mm |
| Inter-Electrode Spacing | 0.5 mm and 1.0 mm (custom spacing available) |
| Electrode Configuration | Side-mounted at tip |
| Connector Type | Redel 14-pin |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT111B (Mouse), FT211B (Rat) |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Scisense FV892 |
| Pricing | Upon Request |
| Pressure Output | 1 V/100 mmHg (custom output ranges available) |
| Power Supply | External AC adapter, ±12 VDC |
| Dimensions (H × W × L) | 16.8 cm × 22.6 cm × 6.9 cm |
| Calibration Control | 10-position output gain switch |
| Catheter Cable Length Options | 91 cm or 152 cm |
| Output Interface | Standard BNC analog output |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Scisense PV Catheter Series (3F, 5F, 7F) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Scisense! |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VSL |
| Pricing | Available Upon Request |
| Brand | Selecta |
|---|---|
| Origin | Spain |
| Model | PhotometerS-2000 |
| Measurement Principle | Continuous Flow (Flow-Through Cuvette System) |
| Detection Reagents | Selecta-branded clinical reagent kits |
| Optical System | Dual-wavelength solid-state photodiode detector with 7 fixed interference filters (340, 405, 500, 546, 578, 620, 670 nm) |
| Bandwidth | 10 nm |
| Cuvette Volume | 30 µL |
| Absorbance Range | 0.000–2.500 ABS |
| Display Resolution | 0.001 ABS |
| Computational Resolution | 0.0001 ABS |
| Temperature Control | Peltier-heated sample holder (setpoints: 25 °C, 30 °C, 37 °C |
| Light Source | 6 V / 10 W tungsten-halogen lamp |
| Lamp Life-Saving Mode | Yes |
| Display | 640 × 240 pixel LCD, 256-color graphics |
| Data Interface | RS-232 serial port |
| Ambient Operating Conditions | 15–32 °C, ≤85% RH (non-condensing) |
| Internal Storage | Up to 134 assay methods, 1000 patient results |
| Preloaded Methods | 47 most common clinical assays (e.g., cholesterol, glucose, serum iron, LDH, AST, urea) |
| Curve Fitting Algorithms | Endpoint, Kinetic, Linear Regression, Multi-Point Calibration, Best-Fit Polynomial, Bichromatic Correction |
| Control Interface | Scroll wheel or external USB mouse |
| Dimensions (H×W×D) | 41.2 × 45.3 × 33 cm |
| Power Supply | 100–220 V AC, 50–60 Hz |
| Weight | 15 kg |
| Optional Accessory | BIO-BATH metal dry-block incubator (37 °C, 8-position, for 75 × 13 mm test tubes) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SN-01 |
| Pricing | Upon Request |
| Brand | SOOHOW INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | STS-A200 |
| Pricing Range | USD 14,000–21,000 |
| Architecture | Discrete Analytical System |
| Instrument Class | Low-Speed Fully Automated (0–400 rpm equivalent throughput logic) |
| Sample Types | Whole Blood, Serum, Plasma, Urine, Cerebrospinal Fluid (CSF) |
| Analyte Class | Specific Proteins (e.g., CRP, IgG, IgA, IgM, C3, C4, ASO, RF, HbA1c, etc.) |
| Throughput | 180 Tests per Hour |
| Optical Principle | Rate Nephelometry and/or Turbidimetry |
| Light Source | 12 V Long-Life Halogen Lamp |
| Wavelength Range | 340–700 nm (8 Fixed Wavelengths) |
| Reaction Temperature Control | 37.0 ± 0.1 °C via Solid-State Direct-Heating with Full-Circumference Thermal Sensors |
| Reaction Vessels | 40 UV-Transparent Cuvettes |
| Sample Capacity | 25 Tubes on 5-Position Rack-Based Continuous Feed |
| Dispensing Accuracy | ±5% at 3–30 µL (Sample), ±5% at 20–200 µL (Reagent) |
| Precision (CV) | ≤5% |
| Carryover | <1% |
| Stability (4h/8h) | Deviation (B) ≤ ±5% vs. Calibrator Assigned Values |
| Compliance | GB/T 14710–2009 (Environmental & Mechanical Robustness), GB 4793.1–2007 / GB 4793.9–2013 / YY 0648–2008 (Electrical Safety), GB/T 18268.1–2010 / GB/T 18268.26–2010 (EMC) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Spin DIALYZER™ and Fast Spin DIALYZER™ |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpinColumnTM 96-Well and 384-Well |
| Pricing | Available Upon Request |
| Sample Volume (384-well) | 10–25 µL |
| Binding Capacity (384-well) | 3–30 µg/tip |
| Sample Volume (96-well Micro) | 25–100 µL |
| Binding Capacity (96-well Micro) | 10–100 µg/tip |
| Sample Volume (96-well Macro) | 25–150 µL |
| Binding Capacity (96-well Macro) | 30–275 µg/tip |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SSI-Human |
| Pricing | Upon Request |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BV-10 |
| Pricing | Upon Request |
| Heating Elements | Platinum-Iridium Wire & Tin-Lead Alloy Wire |
| Minimum Tip Diameter Achievable | < 0.3 µm |
| Control | Digital Precision Control of Heat and Tension (3 Independent Channels) |
| Construction | Corrosion-Resistant Housing |
| Footprint | Compact Benchtop Design |
| Primary Application | Patch-Clamp Electrophysiology, Intracellular Microinjection, Single-Cell Physiology |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | BV-10 |
| Heating Elements | Platinum/Iridium wire and Tin-Lead alloy wire |
| Precision Control | Triple independent digital controllers for heat, pull force, and timing |
| Microscope Integration | Dual-objective stereo microscope (low- and high-magnification objectives for coating and polishing) |
| Construction | Corrosion-resistant chassis |
| Footprint | Compact design for benchtop integration in electrophysiology rigs |
| Application Focus | Patch-clamp electrode conditioning, intracellular microinjection, sharp electrode preparation |
