Medical Instruments
Filter
Showing 31–60 of 254 results
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Beetrode Micro |
| Pricing | Upon Request |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | LB9508 |
| Instrument Type | Electrochemiluminescence Analyzer |
| Automation Level | Fully Automated |
| Detector | Ultra-High-Speed, Low-Noise Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 280–630 nm |
| Detection Sensitivity | <1 amol ATP |
| Sample Introduction | JET Injection Technology |
| Compatible Tube Formats | 12 × 75 mm, 12 × 55 mm, 12 × 47 mm luminometer tubes |
| Injection Volume Range | 10–100 µL or 25–300 µL per channel |
| Injection Accuracy | >98% |
| Software | ICE Operating System with Wizard-Based Interface |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2100S |
| Atomization Method | Tungsten-Boat Electrothermal AAS |
| Wavelength Range | 190–650 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability (30 min preheat, 20 min measurement) | ≤0.009 A |
| Pb/Cd Sensitivity (≤50 µL) | ≥0.055 Abs (Pb), ≥0.025 Abs (Cd) |
| Precision (Abs > 0.1) | ≤4.5% (manual), <1% (with autosampler) |
| Background Correction Capacity | >30× at ~1.0 Abs |
| Power Input | 220 V ± 22 V, 50 Hz ± 1 Hz, 500 VA |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, 0.070–0.106 MPa, vibration- and corrosion-free |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2100T |
| Absorbance Range | 0–2 Abs |
| Wavelength Range | 190–650 nm |
| Baseline Stability | ≤0.009 A (after 30-min preheat, 20-min measurement) |
| Sensitivity (Pb) | ≥0.055 Abs at ≤50 µL |
| Sensitivity (Cd) | ≥0.025 Abs at ≤50 µL |
| Precision (Pb/Cd) | ≤4.5% (Abs > 0.1) |
| Background Correction Capacity | >30× at ~1.0 Abs background |
| Measurement Mode | Dual-channel simultaneous detection |
| Power Input | 500 VA, AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, 0.070–0.106 MPa, vibration-free, non-corrosive, low-EMI |
| Brand | BLS |
|---|---|
| Origin | Imported (Non-Chinese) |
| Manufacturer Type | Authorized Distributor |
| Model | FHS/F-01 |
| Power Source | 4× AA Alkaline Batteries |
| Excitation Light Source | High-Intensity Blue LED Array (440–495 nm) |
| Emission Filter Options | Wideband Barrier Filters (470–660 nm) |
| Optical Design | Adjustable Beam Angle Mechanism |
| Compliance | CE Marked for Laboratory Use |
| Battery Life | Up to 3–4 Months (Typical Intermittent Use) |
| Brand | BLS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | FHS/T00 |
| Excitation Source | External (e.g., FBL/Basic-B&N-01 benchtop unit) |
| Emission Filter Compatibility | ECFP, EGFP, EYFP, DsRed |
| Filter Options | FS/TEF-1C2 (470–500 nm), FS/TEF-2G2 (500–515 nm), FS/TEF-3GY1 (500–650 nm), FS/TEF-3GY2 (500–550 nm), FS/TEF-4Y1 & FS/TEF-4Y2 (520–650 nm), FS/TEF-4R2-A/B/C (590–660 nm) |
| Compatible Excitation Sources | FS/ULS-02RB, FS/ULS-02B2, FS/ULS-02G2N/W |
| Brand | BLS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | FMA-04 |
| Excitation Source | High-Brightness LED(s) |
| Compatible Eyepiece Diameter (D1) | Custom-adaptable, typically 23–30 mm |
| Tube Diameter (D2) | Custom-adaptable, typically 35–45 mm |
| Eyepiece Barrel Length (L1) | Configurable per microscope platform |
| Focal Range (Fmin–Fmax) | 120–220 mm |
| Emission Filter Options | GFP (500–515 nm), GFP/YFP dual-band (500–550 nm), YFP (515–550 nm) |
| Power Supply | 6 V DC |
| Mounting | Three-screw mechanical attachment to focus collar |
| Filter Wheel Positions | “No Filter” (white-light alignment), Green-dot (GFP), Yellow-dot (YFP), Green-Yellow-dot (dual-band) |
| Compliance | CE-marked optical accessory |
| Brand | BLS |
|---|---|
| Origin | Imported (Non-China) |
| Distributor Type | Authorized General Distributor |
| Model | FS/TEF Series |
| Wavelength Ranges | FS/TEF-1C2 (470–500 nm), FS/TEF-2G2 (500–515 nm), FS/TEF-3GY1 (500–650 nm), FS/TEF-3GY2 (500–550 nm), FS/TEF-4Y1 (520–650 nm), FS/TEF-4Y2 (520–650 nm), FS/TEF-4R2 (590–660 nm) |
| Mounting | Standard 25 mm or 32 mm diameter, threaded (M25.5×0.75 or M32×0.75), optical grade anodized aluminum housings |
| Optical Density (OD) | ≥6 at blocking bands |
| Transmission Peak | >90% at center wavelength |
| Steepness | Edge transition <15 nm (typ.) |
| Substrate | Fused silica or BK7, λ/4 surface flatness, AR-coated both sides |
| Brand | BLS |
|---|---|
| Model | GFP-MDS-96/BN |
| Input Voltage | 110/220 V AC |
| LED Configuration | 96 high-brightness LEDs (8 independently steerable excitation channels) |
| Filter Mount | Customizable barrier filter position ahead of objective lens |
| Camera Integration | Adjustable mounting bracket with lens-diameter-specific filter adapter support |
| Intended Use | In situ GFP/YFP visualization in live small-animal housing (e.g., mouse cages) within biosafety cabinets or laminar flow hoods |
| Compliance | Designed for GLP-aligned preclinical imaging workflows |
| Brand | Bohui |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BH400 |
| Pricing | Available Upon Request |
| Detection Principle | Fluorescent Immunochromatography (Dual-Antibody Sandwich) |
| Assay Format | Multiplex Lateral Flow Immunoassay (LFIA) |
| Target Analytes | Rotavirus, Enteric Adenovirus, Norovirus, Astrovirus |
| Measurement Mode | Quantitative Fluorescence Intensity (Excitation/Emission Optimized for Europium Chelate or Similar Lanthanide Label) |
| Linear Range | 0–500 ng/mL (Fluorescein Reference Standard) |
| Background Noise | <50 fluorescence units (10 consecutive blank test strip readings, mean) |
| Accuracy | ±5% of labeled value (fluorescein calibrator) |
| Precision (CV) | ≤10% at 100 ng/mL |
| Stability | <5% signal drift within 20 min |
| Total Assay Time per Sample | <30 s (instrument readout only |
| full assay including sample application and migration | ≤60 min) |
| Power Supply | AC 220 V, 50 Hz |
| Operating Environment | Indoor use |
| Dimensions (W×D×H) | 400 × 436 × 200 mm |
| Brand | Bohui |
|---|---|
| Origin | Beijing, China |
| Model | BH5100T |
| Analysis Method | Flame Atomic Absorption Spectrometry (FAAS) |
| Simultaneous Multi-Element Detection | Cu, Zn, Ca, Mg, Fe |
| Atomizer | Pre-mixed 100 mm single-slit titanium burner |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.15–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.005 Abs (30 min, unignited) |
| Characteristic Concentrations (Cu/Zn/Ca/Mg/Fe) | ≤0.035 / ≤0.015 / ≤0.080 / ≤0.040 / ≤1.05 mg/L per 1% absorption |
| Precision | ≤1.0% RSD (Abs > 0.1) |
| Sample Volume | 20 µL (Enhanced) or 40 µL (Standard) whole blood |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz, 300 VA |
| Dimensions | 720 × 520 × 275 mm |
| Operating Environment | 10–30 °C, RH ≤70%, no vibration/corrosive gases/EMI |
| Safety Compliance | Overpressure Category II, integrated acetylene flashback arrestor, pressure/flow dual monitoring, automatic gas cutoff on power loss or low air pressure |
| Software | Dedicated clinical data management system with GLP-compliant audit trail, automated calculation, storage, and report generation (graphical + tabular output) |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH100 |
| Detection Principle | Fluorescent Immunochromatography (Dual-Antibody Sandwich) |
| Assay Time | <30 s per test |
| Linear Range | 0–500 ng/mL (fluorescein standard, r ≥ 0.990) |
| Background Noise | <50 RFU (10× blank card avg.) |
| Accuracy | ±5% of labeled value (fluorescein calibrator) |
| Precision | CV ≤10% at 100 ng/mL |
| Stability | <5% fluorescence drift within 20 min |
| Power Supply | 220 V, 50 Hz |
| Operating Environment | 10–30 °C, ≤70% RH, altitude <2000 m |
| Dimensions | 400 × 436 × 200 mm |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2101S |
| Analytical Method | Tungsten-Boat Electrothermal Atomic Absorption Spectrometry (ETAAS) |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 1.0–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.009 Abs/20 min (Pb & Cd, after 30-min preheating) |
| Sensitivity | Pb >0.055 Abs, Cd >0.025 Abs (≤50 µL sample) |
| Precision | ≤4.5% RSD (Abs >0.1) |
| Background Correction | Self-reversal (self-absorption) method |
| Measurement Mode | Dual-channel simultaneous detection (Pb & Cd) |
| Power Supply | AC 220 V, 50 Hz, 600 VA |
| Dimensions | 780 × 560 × 470 mm (L×W×H) |
| Weight | 45 kg |
| Operating Environment | 10–30 °C, 0.070–0.106 MPa, vibration-free, non-corrosive, low-EMI |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH2200S |
| Analysis Method | Graphite Furnace Atomic Absorption Spectrometry (GFAAS) |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.10–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.009 Abs/20 min (after 30-min warm-up) |
| Detection Sensitivity | Pb > 0.055 Abs, Cd > 0.025 Abs (≤50 µL injection) |
| Precision | ≤2.9% RSD (Abs > 0.1) |
| Background Correction Capacity | >30× at ~1.0 Abs |
| Signal Measurement | Dual-channel simultaneous detection |
| Power Supply | AC 220 V, 50 Hz |
| Operating Temperature | 10–30 °C |
| Atmospheric Pressure | 0.070–0.106 MPa |
| Dimensions (Main Unit) | 782 × 560 × 338 mm |
| Dimensions (Graphite Furnace Power Supply) | 335 × 470 × 265 mm |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH5300S |
| Analysis Method | Flame Atomic Absorption Spectrometry (FAAS) |
| Sample Types | Whole Blood (40 µL) and Serum (300 µL) |
| Simultaneous Multi-Element Detection | Cu, Zn, Ca, Mg, Fe |
| Atomizer | Premixed 100 mm Single-Slit Titanium Burner |
| Absorbance Range | 0–2 Abs |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.15–2.0 nm |
| Light Sources | Composite Hollow Cathode Lamps (Cu/Zn/Ca |
| Baseline Stability | ≤0.005 Abs per 30 min |
| Characteristic Concentrations (Whole Blood) | Cu ≤0.035 mg/L/%, Zn ≤0.015 mg/L/%, Ca ≤0.080 mg/L/%, Mg ≤0.040 mg/L/%, Fe ≤1.05 mg/L/% |
| Characteristic Concentrations (Serum) | Cu ≤0.035 mg/L/%, Zn ≤0.020 mg/L/%, Ca ≤1.30 mg/L/%, Mg ≤0.20 mg/L/%, Fe ≤0.15 mg/L/% |
| Precision | ≤1.0% RSD (Abs > 0.1) |
| Safety Compliance | Overpressure Category II, Integrated Acetylene Anti-Flashback Valve, Air Pressure & Flow Monitoring, Power-Fail Flame Cutoff, Burner Explosion Protection |
| Power Supply | AC 220 ±22 V, 50 ±1 Hz, 300 VA |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free, Corrosion- and EMI-Free |
| Brand | Bohui Innovation |
|---|---|
| Origin | Beijing, China |
| Model | BH5500S |
| Analysis Method | Flame Atomic Absorption Spectrometry (FAAS) |
| Sample Types | Whole Blood, Serum, Breast Milk, Urine |
| Simultaneous Multi-Element Detection | Cu, Zn, Ca, Mg, Fe |
| Atomizer | Premixed 100 mm Single-Slit Titanium Burner |
| Wavelength Range | 190–650 nm |
| Spectral Bandwidth | 0.15–2.0 nm |
| Absorbance Range | 0–2 Abs |
| Baseline Stability | ≤0.005 Abs per 30 min (for Cu, Zn, Ca, Mg, Fe) |
| Precision | ≤1.0% RSD (Abs > 0.1) |
| Light Sources | Composite Hollow Cathode Lamps (Cu/Zn/Ca |
| Monochromator | Holographic Grating |
| Nebulizer | Optimized High-Efficiency Pneumatic Nebulizer |
| Nebulization Chamber | PTFE-lined with Tapered Geometry and Rear Drain Design |
| Burner Head | Pure Titanium |
| Safety Systems | Acetylene Anti-Flashback Valve, Pressure/Flow Dual Monitoring, Power-Fail Cut-off, Burner Explosion Protection |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz, 300 VA |
| Dimensions | 782 × 560 × 338 mm |
| Operating Environment | 10–30 °C, RH ≤70%, Atmospheric Pressure 0.070–0.106 MPa, Vibration-Free & Corrosion-Free Ambient |
| Software | Integrated Clinical FAAS Data Acquisition & Reporting Suite with Audit Trail Capability |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bronchospasm Measurement System |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 115FP |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 560TP |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 625FS |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 840MD |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DMF-1000 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FTP-22-25 to FTP-13-150 |
| Sterility | Ethylene Oxide (EO) Sterilized |
| Material | Medical-Grade Polypropylene Shaft + Medical-Grade Silicone Bulb Tip |
| Gauges | 22G–13G |
| Lengths | 25 mm–150 mm |
| Packaging | Individually Wrapped, Sterile Unit Dose |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AVANCE IVDr |
| Pricing | Available Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | inNO Model-T-II |
| Pricing | Upon Request |
| Brand | Buide |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | BUI |
| Pricing | Available Upon Request |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | DBS-MS 500 |
| Application Interface | Direct Coupling to LC-MS and MS Systems |
| Throughput | Up to 500 DBS Cards per Run |
| Integrated Modules | OCR Identification, ISA (Internal Standard Addition), Solvent-Based Extraction, Full-Path Cleaning Station |
| Compliance | Designed for GLP/GMP-Compliant Bioanalytical Laboratories |
| Software | CAMAG WinCATS Pro with Audit Trail & User Management (21 CFR Part 11 Ready) |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240S |
| Video Sensor | 1/3" CCD, 2 MP |
| Optical Zoom | ≥12× |
| Digital Zoom | ≥8× |
| Max Composite Magnification | 105× |
| Video Resolution (Digital/USB) | 2048×1024 @ 15 fps |
| Analog Output | VGA/AV, 800 TV lines @ 30 fps |
| SNR | ≥48 dB |
| Sync Latency (Video vs. Physio Signal) | <0.1 s |
| Lighting | Dual LED side illumination + cold-cathode backlight (≥2 W) |
| Input/Output | Dual VGA, Dual RGB (DB15), AV (RCA), RS-232, Audio In/Out |
| Software | USB video capture module + synchronized physiological waveform recording (MPEG-4 compression), standalone or integrated mode, annotation, freeze, invert, zoom, rotation, text overlay |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYW-600S |
| Price | USD 3,500 (FOB) |
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | Qi3536 |
| Power Consumption | 3 W |
| Display | 20×2 large-character LCD |
| Data Retention | Non-volatile memory with power-loss protection |
| Counting Modes | Bone marrow smear, peripheral blood smear, megakaryocyte count, histochemical staining |
| Cell Categories | 58 defined cell types across granulocytic, erythroid, megakaryocytic, plasmacytic, monocytic, lymphoid, and other lineages (e.g., fat cells, mast cells, reticular cells, osteoblasts, osteoclasts) |
| Staining Intensity Grading | –, +, ++, +++, ++++ |
| Output Metrics | Absolute counts, percentages, five diagnostic ratios (e.g., myeloid:erythroid), six lineage totals, non-erythroid cell summary |
| Input Volume | 10 µL per chamber |
| Operating Modes | AC/DC dual-power supply |