Medical Instruments
Filter
Showing 211–240 of 254 results
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | EG-400 |
| Motor Speed | 50–2000 rpm |
| Electrode Manipulator Travel | 47 mm (vertical) |
| Microscope Travel | X: 7 mm, Y: 30 mm, Z: 8 mm |
| Magnification | 30× (10× eyepiece × 3× objective) |
| Capillary Outer Diameter Range | 1.0–1.5 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMP-100D |
| Pricing | Upon Request |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | M3301 |
| Weight | 550 g |
| Transport Weight | 1.4 kg |
| X-Axis Travel | 10 mm & 37 mm (dual-range configuration) |
| Y-Axis Travel | 25 mm |
| Z-Axis Travel | 25 mm |
| X-Axis Resolution | 0.01 mm (fine) / 0.1 mm (coarse) |
| Y/Z-Axis Resolution | 0.1 mm |
| Mounting Interface | Standard 12 mm clamp & Electrode Holder M3301EH |
| Handedness | Left- and Right-Hand Configurations Available |
| Guidance System | Precision V-groove rails with roller bearings |
| Structural Material | Stainless steel moving components |
| Optical Compatibility | Designed for integration with upright/inverted microscopes up to 250× magnification |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MF-900 |
| Heating Stage Travel (X/Y/Z) | 14 mm / 14 mm / 14 mm |
| Micropipette Manipulator Travel (X/Z) | 12 mm / 28 mm |
| Microscope Stage Travel (X/Y/Z) | ~7 mm / 30 mm / ~8 mm |
| Microscope Magnification | 50× / 100× (10× eyepiece, 5× & 10× objectives) |
| Capillary Outer Diameter | 1.0 mm |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MM-33 |
| Control Type | Manual |
| Coarse Adjustment Range (X/Y/Z) | 37 mm / 20 mm / 20 mm |
| Coarse Resolution | 0.1 mm per axis |
| Fine Adjustment Range (X) | 10 mm |
| Fine Resolution | 0.01 mm |
| Rotational Base | Lockable, Dual-Axis (Horizontal & Vertical) |
| Mounting Compatibility | Magnetic base, standard dovetail or clamp-style stage adapters |
| Intended Use | Electrophysiology, patch-clamp, microinjection, and extracellular stimulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP-285 |
| Drive Type | Motorized (DC stepper motor) |
| Axes | 4-axis (X, Y, Z, Oblique) |
| Travel Range | 25 mm per axis |
| Minimum Step Resolution | 0.04 µm (high-res mode) / 0.2 µm (low-res mode) |
| Maximum Speed | 2.9 mm/sec |
| Drift | ≤10 nm/hr at 24°C |
| Position Display | LCD with real-time X/Y/Z coordinate readout (µm resolution) |
| Control Modes | Continuous motion and discrete step motion |
| Programmability | RS-232 and USB interface for external computer control |
| Homing Function | Yes (user-defined HOME position) |
| Microscope Compatibility | Universal mounting (standard dovetail and adapter plates) |
| Compliance | Designed for GLP-compliant electrophysiology workflows |
| Software Integration | Compatible with SutterPatch, PatchMaster, and third-party acquisition platforms (e.g., Axon pCLAMP, HEKA PatchMaster) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP-85 |
| Axes | XYZ motorized with manual coarse/fine/ultra-fine adjustment |
| X-axis rotation | 0–45° in 15° increments |
| Coarse resolution (XYZ) | 0.1 mm |
| Fine resolution (X-axis) | 0.01 mm |
| Ultra-fine resolution (X-axis) | 0.2 µm |
| Dimensions | 25 mm × 25 mm × 25 mm |
| Compliance | Designed for electrophysiology, patch-clamp, and intracellular injection workflows under GLP-aligned laboratory practices |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP225 |
| Movement Axes | X, Y, Z, and Oblique (4-axis) |
| Resolution | 0.0625–2.0 µm/step (selectable) |
| Maximum Travel | 25.4 mm per axis |
| Minimum Step Size | 0.04 µm (high-resolution mode) |
| Maximum Speed | ≥ 2.9 mm/sec |
| Thermal Drift Stability | ≤ 10 nm/h at 24°C |
| Drive Mechanism | Precision Lead-Screw Actuation |
| Position Display | Real-time LCD readout in micrometers |
| Return-to-Home Function | Yes |
| Motion Modes | Continuous, Stepped, Joystick, FSR Piezo Assist, ROE200 Rotary Encoder Control |
| Programmability | Multi-step motion sequences supported |
| Compatibility | Universal mounting for upright & inverted microscopes |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows requiring traceable positioning and audit-ready operation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-385-2 |
| Controller | MPC-200 |
| Manipulators | (2) MP-285 |
| Rotary Encoder Module | ROE-200 |
| Axes | X, Y, Z, Oblique |
| Travel Range | 25 mm per axis |
| Max Speed | 5 mm/s |
| Resolution | 0.04 µm (high), 0.2 µm (low) |
| Drift | ≤10 nm/hr at 24°C |
| Motion Modes | Continuous & Step |
| Programmable | Yes, via RS-232/USB |
| Homing Function | Yes |
| Compatibility | Universal microscope mounting |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC325-2 |
| Axes | X, Y, Z, and Oblique (4-axis) |
| Travel Range | 25.4 mm per axis |
| Step Resolution | 0.0625–2.0 µm |
| Maximum Speed | 3 mm/s |
| Thermal Drift | ≤10 nm/h at 24°C |
| Drive Mechanism | Precision Lead-Screw |
| Position Display | LCD (µm resolution) |
| Control Modes | ROE200 Rotary Encoder, FSR Piezo Controller, Joystick |
| Repeatability Function | Yes |
| Compatibility | Universal Microscope Mounting |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-2000 |
| Heating Source | CO₂ Laser |
| Max Capillary OD | Glass 1.5 mm / Quartz 1.8 mm |
| Min Capillary OD | Glass 0.125 mm / Quartz 0.6 mm |
| Tip Diameter Range | 5–10 µm (reproducible down to ≤0.03 µm) |
| Programmable Protocols | 100 |
| Laser Lifetime | >10 years |
| Control System | Microprocessor-based with write-protected timestamp logging |
| Symmetry | Dual-symmetric pull per cycle |
| Compliance | GLP-compliant audit trail capability (timestamped protocol execution logs) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-30 |
| Heating Element Options | Platinum-Iridium or Nichrome Coil |
| Dual-Pipette Capability | Yes |
| Tip Diameter Range | Down to 0.3 µm |
| Pipette Length Range | 10–15 mm |
| Control Interface | Three Digital Knobs (Heat, Pull, Velocity) |
| Precision Adjustment | Integrated Micrometer for Repeatable Pull Length |
| Power Supply | Constant-Current Source for Heater and Pull Solenoid |
| EMI Suppression | Built-in RFI Filtering |
| Voltage/Frequency Options | Dual (115 V / 60 Hz & 230 V / 50 Hz) |
| Clamp Material | Rubber-Padded Stainless Steel |
| Construction | Corrosion-Resistant Components |
| Application Focus | Patch-Clamp Electrophysiology, Intracellular Recording, Microinjection |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal programmable micropipette puller for electrophysiology and microinjection |
| Heating mechanism | Resistive filament (tungsten/platinum coil) with precision-controlled current |
| Pulling force | Pneumatically actuated, programmable pressure and release timing |
| Control system | Embedded microprocessor with 100-program non-volatile memory |
| Display | Vacuum fluorescent display (VFD) |
| Filament and solenoid power supply | Constant-current |
| Electrode symmetry | Dual symmetric pipettes per pull |
| Tip diameter reproducibility | ≤0.06 µm (SEM-verified), routinely <0.1 µm |
| Cooling mode | Optional external airflow for large-diameter/multi-barrel glass |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Swivel Mounts |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T-Maze |
| Pricing | Available Upon Request |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADME |
| Pricing | Available Upon Request |
| Brand | Tekscan |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F-Scan GO |
| Pricing | Available Upon Request |
| Brand | Terumo BCT |
|---|---|
| Origin | USA |
| Model | Spectra Optia® |
| Device Type | Automated Blood Separation and Cell Processing Platform |
| Regulatory Classification | FDA-cleared Class II Medical Device (510(k) K122936, K151487, etc.) |
| Weight | 90 kg |
| Extracorporeal Volume | ≥110 mL |
| Patient Weight Range | 2–227 kg |
| Data Storage Capacity | 100 patient sessions |
| Integrated Tube Sealer | Yes |
| Power Failure Memory | Yes |
| User Interface | Color Touchscreen GUI with Multilingual Support (including Simplified Chinese) |
| Key | Brand: Thermal Technology |
|---|---|
| Model | NTE-2A |
| Temperature Range | 0–50 °C |
| Control Accuracy | ±0.1 °C |
| Resolution | 0.1 °C |
| Probe Tip Diameter | 13 mm |
| Probe Length | 16.5 cm |
| Response Time (Heating/Cooling) | <4 s |
| Base Temperature Adjustment Range | 20–30 °C |
| Input Power | 200–240 V AC, 50 Hz, 100 W |
| Dimensions | 20.3 × 17.8 × 38.1 cm |
| Weight | 12.7 kg |
| Compliance | ASTM F2696 (Standard Guide for Quantitative Sensory Testing), ISO 13485 (Medical Devices), FDA 21 CFR Part 11 (Software Validation Ready) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Global Manufacturing Network |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Indiko / Indiko Plus |
| Pricing | Available Upon Request |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HCY-20 |
| Sample Volume | 40 mL |
| Oil Content Range | 0.1%–100% (w/w) |
| Measurement Accuracy | ±0.2% |
| Measurement Stability | ±0.1% |
| Power Supply | 220 V, 50 Hz |
| Rated Power | ≤40 W |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HCY-20 |
| Power Supply | 220 V, 50 Hz |
| Rated Power | ≤40 W |
| Sample Volume | 40 mL |
| Oil Content Range | 0.1–100% (w/w) |
| Measurement Accuracy | ±0.2% (relative to reference gravimetric extraction) |
| Measurement Stability | ±0.1% (RSD over 24 h under controlled conditions) |
| Display | Color LCD with mouse & keyboard interface |
| Data Export | USB flash drive compatible |
| Firmware Update | USB-based software upgrade |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | TSE-7300G |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultra Fast DIALYZERTM |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Ultra-Micro Dispo DIALYZERTM |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Ultra-Micro PrepTip™ |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultra-Micro/Micro SpinColumnTM |
| Pricing | Available Upon Request |
| Sample Volume Capacity | 10–25 µL (Ultra-Micro) / 25–75 µL (Micro) |
| Binding Capacity | 3–30 µg/tip (Ultra-Micro) / 5–60 µg/tip (Micro) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Ultra-Micro/Micro TipColumnTM |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultramicropump III |
| Pricing | Available Upon Request |
| Brand | URIT |
|---|---|
| Model | UC-A580Vet |
| Origin | Guangxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |