Medical Instruments
Filter
Showing 61–90 of 251 results
| Brand | Chuanyi Instruments (Hangzhou Chuanyi Electronic Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Qi3537 |
| Pricing | Upon Request |
| Brand | Chuanyu Instruments (Shanghai) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | Qi3536 |
| Price Range | USD 490 – 560 |
| Brand | Chuanyuyiqi |
|---|---|
| Origin | Shanghai, China |
| Model | Qi3537 |
| Power Supply | 12 V DC (with AC adapter) |
| Display | 16×2 character LCD |
| Counting Modes | Peripheral Blood Smear, Bone Marrow Aspirate, Megakaryocyte, Histochemical Staining |
| Cell Categories | 32 defined morphological types across granulocytic, erythroid, megakaryocytic, lymphoid, monocytic, and undifferentiated lineages |
| Counting Volume per Chamber | 9 × 10⁻³ mL |
| Chamber Dimensions | 9 large squares (each 0.1 mm³ / 1.0 × 10⁻⁴ mL) |
| Interface | RS232 serial port for data export |
| Software Features | PC-based analysis with patient ID, lab name, date/time stamp, annotation fields, pre-/post-treatment comparison, audit-ready session logging |
| Predefined Protocols | LEUC (14 leukocyte subtypes), MYEL (14 bone marrow cell types), RETI (reticulocyte + RBC dual-count), and HISTO (4-grade histochemical intensity scoring) |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 1 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LabLincV |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | CrystalCam |
| Price | ¥1,000,000 |
| Spatial Resolution | 1 mm |
| Temporal Resolution | 80,000 fps |
| Gray Scale | 256 levels |
| Time Gain Control (TGC) | 100 dB |
| Measurement Function | Radionuclide Distribution Imaging |
| Dynamic Range Adjustment | 100–130 dB |
| Display Modes | Radionuclide Scintigraphy, SPECT/CT Fusion |
| Maximum Penetration Depth | 1000 mm |
| Dimensions | 65 × 65 × 180 mm³ |
| Weight | 800 g (incl. collimator & shielding) |
| Integrated Lateral Shielding | 99.97% attenuation for ⁹⁹ᵐTc |
| Field of View | 40 × 40 mm² @ 16 × 16 pixels |
| Energy Range | 50–240 keV (optional: 50–1000 keV) |
| Energy Resolution | <5.5% FWHM at 140 keV (⁹⁹ᵐTc) |
| Sensitivity | >500,000 cps/MBq (uncollimated), >2,000 cps/MBq (LEHS), >450 cps/MBq (LEHR), >190 cps/MBq (LEGP) |
| Extrinsic Spatial Resolution | 5.4 mm FWHM at 35 mm (LEHR), 9.2 mm FWHM at 35 mm (LEHS), 6.1 mm FWHM at 35 mm (LEGP) |
| Power Supply | USB-powered |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS200 |
| Pricing | Available Upon Request |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Gasboard-7030 |
| Pricing | Available Upon Request |
| Volume Range | 0–10 L |
| Flow Rate Range | 0–20 L/s |
| Volume Accuracy | ±0.2% or ±10 mL |
| Volume Resolution | 0.3829 mL |
| Flow Rate Accuracy | ±0.5% or ±25 mL/s |
| BTPS Simulation | 37 °C ±2 °C, 92% RH ±5% |
| Waveform Types | Sine, Square, Trapezoidal, User-Defined |
| Compliance Standards | ATS-24, ATS-26, ISO 23747:2015 (Peak Flow Annexes A & B), EN ISO 26782:2009 (Tests C1–C11, Annexes C12–C13) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-7050 |
| Calibration Volume | 3000 mL |
| Accuracy | ±15 mL |
| Piston Interface Outer Diameter | Φ28 mm |
| Operating Temperature | 15–40 °C |
| Storage Temperature | 0–50 °C |
| Storage Relative Humidity | 10–95 %RH |
| Dimensions (L×W×H) | 590 × 113 × 116.5 mm |
| Weight | 2.5 kg |
| Compliance | JJF 1213–2008 Calibration Specification for Pulmonary Function Instruments |
| Brand | BLS |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | Custom Camera Filter |
| Pricing | Available Upon Request |
| Filter Types | FS/CEF-1C2, FS/CEF-2G2, FS/CEF-3GY2, FS/CEF-3GY1, FS/CEF-4Y3, FS/CEF-4Y2, FS/CEF-4Y1, FS/CEF-4R2, FS/CEF-4O2 Emission Filters |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CYW-300S |
| Price | USD 1,700 (FOB) |
| Filter Diameter | Φ47 mm / Φ50 mm |
| Effective Filtration Area | 40 mm |
| Cup Capacity | 100 mL |
| Number of Filtration Heads | 3 |
| Filtration Method | Vacuum-Driven Membrane Filtration |
| Filtration Rate | 100 mL per 15 s |
| Sterilization Options | Autoclave (121 °C, 15–20 min), Flame Sterilization (for filtration heads only) |
| Filtration Head Design | Removable, Lip-Seal Integrated, Clamp-Free, O-Ring-Free |
| Pump Interface | External Oil-Free Vacuum Pump (not included) |
| Material | Electropolished 316L Stainless Steel Base & Filtration Heads |
| Surface Finish | Mirror-Polished AISI 316L SS |
| Compliance | Designed in accordance with ISO 8573-1 (compressed air purity), USP <61> & <62>, Ph. Eur. 2.6.12, and Chinese Pharmacopoeia 2020 Edition IV.1107 |
| Brand | Deerse/DS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DK-200 |
| Price | USD 355 (FOB) |
| Temperature Range | Adjustable 25–70°C |
| Temperature Stability | ±0.5°C |
| Ambient Operating Temperature | 0–40°C |
| Power Supply | AC 220V 50Hz / AC 110V 60Hz |
| Rated Power | 300 W |
| Overall Dimensions | 330 × 330 × 90 mm |
| Bath Chamber Dimensions | 250 × 200 × 60 mm |
| Heating Element | Surface-Mounted Imported Polymer Heating Film |
| Illumination | Integrated LED Task Light with Diffused Beam Profile |
| Dust Protection | Removable Acrylic Dust Cover (Patent Pending) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | DeskCAT |
| Quotation | Upon Request |
| Medical Device Registration Number | Not Applicable |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | DIALYZERTM |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Dispo Equilibrium DIALYZER™ |
| Pricing | Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 110P |
| Quotation | Upon Request |
| Vessel Diameter Range | >60 µm |
| Axial Alignment | Manual X/Y/Z Adjustment |
| Bath Volume | Up to 10 mL (3 mL Standard) |
| Bath Material | Acid-Resistant Stainless Steel |
| Tension Range | ±50 mN |
| Tension Resolution | 0.01 mN |
| Pressure Range | 0–250 mmHg |
| Pressure Resolution | 0.1 mmHg |
| Temperature Control | Built-in Electronic Feedback Heating |
| Temp Range | Ambient to 50 °C |
| Temp Accuracy | ±0.1 °C |
| Analog Output | 1.0 V F.S. (12-bit) |
| Digital Interface | RS232 / RS485 |
| Power Input | 100–240 VAC, Auto-Switching, 50/60 Hz |
| Environmental Operating Range | 15–30 °C |
| Optional Modules | Flowmeter (15–1500 µL/min), pH Meter (0–14, 0–50 °C), Peristaltic Pump (2.5–50 rpm) |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMT 110P |
| Pricing | Upon Request |
| [Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 111P |
| Price | Upon Request |
| Vessel Diameter Range | >60 µm |
| Tension Range | ±50 mN |
| Tension Resolution | 0.01 mN |
| Pressure Range | 0–250 mmHg |
| Pressure Accuracy | ±0.1 mmHg |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.1 °C |
| Bath Volume | Up to 10 mL (3 mL standard) |
| Bath Material | Acid-Resistant Stainless Steel |
| Heating | Integrated Electronic Feedback Control |
| Analog Output | 1.0 V F.S. (12-bit) |
| Digital Interface | RS232 / RS485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Environmental Operating Temp | 15–30 °C] |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMT 111P |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 161FM |
| Pricing | Available Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMT 620M |
| Price | Upon Request |
| Sample Diameter Range | 60 µm to 10 mm |
| Number of Baths | 4 independent stainless-steel baths |
| Bath Capacity | Up to 8 mL per bath |
| Tension Range Options | ±200 / ±400 / ±800 / ±1600 mN |
| Tension Resolution | 0.1 mN |
| Temperature Control Range | Ambient to 45 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating System | Integrated electronic heating with independent bath temperature regulation |
| Bath Exhaust | Manual or programmable automatic aspiration |
| Gas Inlet | Individual needle-valve control per bath |
| Analog Output | 2.5 V full-scale, 4-channel isolated |
| Digital Interface | USB 2.0 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Ambient | 15–30 °C |
| Calibration | Semi-automatic weight calibration |
| Positioning | Manual micrometer-driven micro-positioner |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 620M |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310A / 410A / 510A |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSI Implantable Physiological Signal Telemetry System |
| Pricing | Available Upon Request |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AA-7030A |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ElectroPrep™ System |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Fast Macro Dispo DIALYZERTM |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Fast Micro-Equilibrium DIALYZERTM |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Five-Hole Box System |
| Price | Upon Request |
