| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Move DC |
| Instrument Type | Portable |
| Measurement Principle | DPD-based Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone, Cyanuric Acid, pH |
| Range | 0.02–4.5 mg/L (for chlorine species and ozone) |
| Accuracy | ±3% of reading |
| Repeatability | ±0.02 mg/L |
| Absorbance Resolution | 0.01 A |
| LOD | 0.02 mg/L |
| Optical System | LED light source, interference filter, photodiode detector, transparent cuvette chamber |
| Wavelength | 530 nm |
| Display | LCD |
| Power | 4 × AAA batteries (up to 17 h operation or ~5,000 measurements) |
| Weight | 260 g |
| Dimensions (instrument) | 155 × 75 × 35 mm |
| Enclosure Rating | IP68 |
| Memory Capacity | 16 measurement records |
| Data Transfer | Optional Spectroquant® IRiM infrared interface |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Spectroquant® Prove |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | COD, Ammonia-Nitrogen, Total Phosphorus, Total Nitrogen |
| Optical Range | Prove 100 (320–1100 nm), Prove 300/600 (190–1100 nm) |
| Light Source | Tungsten Halogen (Prove 100), Xenon Flash Lamp (Prove 300 & 600) |
| Spectral Bandwidth | 4.5 nm (Prove 100/300), 1.8 nm (Prove 600) |
| Cuvette Compatibility | Round (13 mm, 16 mm) and Rectangular (10 mm, 20 mm, 50 mm, 100 mm) |
| AQA Compliance | Built-in Analytical Quality Assurance per ISO/IEC 17025 and DIN EN ISO 9001 guidelines |
| Data Transfer | USB, Bluetooth, optional Ethernet |
| Software | Spectroquant® Method Manager v5.x with FDA 21 CFR Part 11-compliant audit trail |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | NOVA60A |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | COD, Total Phosphorus, Total Nitrogen, and over 50 additional water quality parameters |
| Wavelength Range | 340–820 nm (12 fixed wavelengths) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | –0.300 to 3.200 A |
| Cuvette Compatibility | 10 mm, 20 mm, 50 mm square cuvettes and 16 mm round tubes (auto-recognized) |
| Barcode Method Recognition | Yes |
| Light Source | Tungsten halogen lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Quality Control Modes | 3 AQA modes (including zero-point correction and turbidity compensation) |
| Internal Memory | Up to 1000 measurement results |
| User-Defined Methods | Up to 50 custom calibration curves (10 at fixed wavelengths) |
| Real-Time Clock | Yes |
| Interface | RS232C (for PC connection, printer output, and method updates) |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | –25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.3 kg |
| Battery Option | Rechargeable battery available for field use |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Picco COD/CSB |
| Pricing | Available Upon Request |
| Optical System | LED Light Source with Interference Filter at 605 nm |
| Measurement Accuracy | ±3.5% |
| Measurement Time | 3–4 seconds |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 30–90% RH (non-condensing) |
| Power Supply | 9-V Alkaline Battery (≈600 measurements per set) |
| Auto-Off Delay | ~5 minutes after last keypress |
| Safety Certifications | CE compliant per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |
| Sample Cell Format | 16 mm round glass cuvettes |
| Required Pre-treatment | Digestion using external COD digestion unit (e.g., Merck Spectroquant® Thermoreactor) |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Prove100 / Prove300 / Prove600 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Total Phosphorus, Total Nitrogen |
| Wavelength Range | Prove100: 320–1100 nm |
| Prove300 & Prove600 | 190–1100 nm |
| Light Source | Prove100: Tungsten Halogen Lamp |
| Prove300 & Prove600 | Xenon Flash Lamp |
| Spectral Bandwidth | Prove100 & Prove300: 4 nm |
| Prove600 | 1.8 nm |
| Absorbance Range | ±3.0 Abs |
| Absorbance Resolution | 0.001 Abs |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.1% T at 340 nm (all models) |
| Sample Holders | 16-mm round cuvettes |
| Built-in Methods | Pre-programmed Spectroquant® test protocols + 99 user-defined methods + 20 wavelength-scan/dynamic methods |
| Compliance | EN 61010-1, IEC 61010-1, EN IEC 61326-1, 2004/108/EC |
| IP Rating | IP31 |
| Operating Temperature | 10–35 °C |
| Dimensions | 416 × 276 × 237 mm |
| Weight | 6.8 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Pharo100 |
| Price | Upon Request |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A) |
| Cuvette Types | 16 mm round, and 10/20/50 mm square (auto-recognized) |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan, Kinetics |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, USEPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectroquant Multy |
| Price | Upon Request |
| Display | 6-digit LCD with backlight |
| Wavelengths | 430 nm, 530 nm, 560 nm, 580 nm, 610 nm, 660 nm (fixed LED sources) |
| Optical Technology | Dual-beam photometry with interference filter compensation |
| Temperature Compensation | 6-point automatic |
| Sample Holders | 16 mm and 24 mm round cuvettes (included) |
| Dimensions (instrument) | 265 × 195 × 70 mm |
| Dimensions (carrying case) | 440 × 370 × 140 mm |
| Interface | RS232 serial port |
| Power Supply | Rechargeable NiCd battery pack (7 cells) |
| Operating Conditions | 0–50 °C, <90% RH (non-condensing) |
| Data Storage | 1000 measurement records with timestamp, parameter ID, and user-defined sample ID |
| Keypad | Chemical-resistant capacitive touch keys |
| Self-Test | Automatic power-on diagnostic routine |
| Compliance | Designed to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 180.1, and EN ISO 15704 for colorimetric water analysis |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | HY-lite |
| Portability | Handheld, Battery-Powered |
| Detection Principle | Firefly Luciferase–Mediated Bioluminescence |
| Measurement Range | 0.01–999.9 RLU (Relative Light Units) |
| Response Time | ≤60 seconds |
| Data Storage Capacity | 2,000 test records |
| Interface | USB 2.0 for PC connectivity |
| Optional Peripherals | Integrated thermal printer module, surface swab pens, liquid sampling pens, jet fuel test kits, free ATP assay pens, ATP calibration standards (0.0 ng/mL) |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned hygiene verification workflows |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Spectroquant® Move |
| Instrument Type | Portable |
| Measurement Principle | Absorption Photometry (LED-based, Fixed-Wavelength) |
| Measured Parameters | Residual Chlorine, Chlorine Dioxide, and Other Water Quality Parameters (via Preloaded Methods) |
| Range | 0.02–6 mg/L |
| Accuracy | ±1 nm (wavelength), ±3% FS (absorbance, 20–25°C) |
| Repeatability | ≤3% RSD |
| Resolution | 0.01 A (absorbance), 1 mAbs (instrumental) |
| LOD | 0.0035 mg/L |
| Wavelength | 530 nm |
| Light Source | High-Stability LED |
| Optical Path | Fixed 10-mm Cuvette Chamber |
| Display | LCD with Backlight |
| Keyboard | Chemical-Resistant Membrane |
| Power | 4 × AAA batteries (up to 17 h operation or ~5,000 measurements) |
| Weight | 260 g |
| Dimensions (H × W × D) | 155 × 75 × 35 mm |
| Carry Case Dimensions | 340 × 270 × 80 mm |
| Ingress Protection | IP68 |
| Data Storage | 16 measurement results |
| Data Transfer | Optional Infrared Interface (Spectroquant® IR Adapter) |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Move100 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | COD, Ammonia-Nitrogen (NH₃-N), Total Phosphorus (TP) |
| Protection Rating | IP68 |
| Preloaded Calibration Curves | >100 |
| Compliance | AQA (Analytical Quality Assurance) Function Enabled |
| Regulatory Context | Designed for field use in compliance with ISO 7027, ISO 6060, ISO 15681-1, and EPA Method 410.4 / 365.2 / 365.3 |
| Brand | Merck Millipore |
|---|---|
| Type | Stirred Cell |
| Model | Amicon® Ultrafiltration Cell (11 mL capacity) |
| Max Operating Pressure | 100 psi (6.9 bar) |
| Effective Membrane Area | 4.2 cm² |
| Sample Volume Range | 0.5–11 mL |
| Material | Anodized Aluminum Body, PTFE Seals, Stainless Steel Stir Bar |
| Compatibility | Sterilizable (Autoclavable at 121°C), Solvent-Resistant Options Available |
| Compliance | Meets ASTM D4187 and ISO 15713 for membrane performance evaluation |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NOVA30 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Wavelengths | 340, 445, 525, 550, 605, 690 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | −0.300 to 3.200 A |
| Light Source | Tungsten Halogen Lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Cuvette Format | 16 mm round tubes |
| Barcode Method Recognition | Yes |
| AQA Modes | 3 (including zero-point and turbidity correction) |
| Data Storage Capacity | Up to 500 results |
| Interface | RS232-C |
| Real-Time Clock | Integrated |
| Power Supply | 220 V, 50 Hz with optional rechargeable battery |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | −25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.8 kg |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Spectroquant® Move DC |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Measurable Parameters | Residual Chlorine, Total Chlorine, Chlorine Dioxide, Ozone, pH, Cyanuric Acid |
| Optical System | LED Light Source, Interference Filter, Photodiode Detector, Transparent Cuvette Chamber |
| Wavelength | 530 nm |
| Absorbance Accuracy | ±0.02 A (at 1.0 A) |
| Absorbance Resolution | 0.01 A |
| Display | LCD with Backlight |
| Keypad | Chemical-Resistant Membrane (Acid & Solvent Proof) |
| Power Supply | 4 × AAA Batteries (Up to 17 h Operation or ~5,000 Measurements) |
| Weight | 260 g (Instrument Only) |
| Dimensions (L × W × H) | 155 × 75 × 35 mm |
| Carry Case Dimensions | 340 × 270 × 80 mm |
| Ingress Protection | IP68 |
| Memory Capacity | 16 Measurement Records |
| Data Transfer | Optional Spectroquant® IRiM Infrared Interface for Printing and PC Export |
| Compliance | Designed for ASTM D1253, ISO 7393-2, USP <643>, EPA 330.5, and GLP/GMP-Aware Workflow Support |
| Brand | Millipore |
|---|---|
| Origin | Switzerland |
| Model | MAS-100 CG Ex |
| Sampling Principle | Impaction-based Active Separation |
| Flow Rates | 50 L/min and 100 L/min (selectable, constant) |
| Flow Measurement Accuracy | ±0% to +10% at 50 L/min or 100 L/min over absolute pressure range of 1.5 bar to 10 bar |
| Total Operating Time | Approx. 3.5 h per battery charge |
| Ambient Temperature Range | 0–40°C |
| Ambient Relative Humidity | Up to 80% RH at ≤31°C, linearly decreasing to 50% RH at 40°C |
| Certifications | ATEX II 2G Ex db IIB T4 Gb / II 2D Ex tb IIIC T135°C Db (for use in Zone 1 & Zone 21 hazardous areas) |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Spectroquant® Move100 |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Total Nitrogen, Total Phosphorus, Free Chlorine, Total Chlorine, Hardness, Phosphate, Sulfate, Iron, Copper, etc. |
| Light Source | LED (430, 530, 560, 580, 610, 660 nm) |
| Wavelength Accuracy | ±2% of range |
| Photometric Range | 0–2 A |
| Linearity Accuracy | ±0.002 A (0–1 A) |
| Linearity Repeatability | ±0.002 A (0–1 A) |
| Wavelength Selection | Automatic |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Data Storage | 1,000 measurements with timestamp, ID, and sample registration |
| Connectivity | IRiM infrared transmitter + PC interface via USB/serial adapter |
| Power Supply | 4 × AA alkaline batteries |
| Ingress Protection | IP68 |
| Weight | 470 g |
| Operating Environment | 0–50 °C, ≤90% RH |
| Included Accessories | Instrument body, carrying case, 4 AA batteries, three 24-mm cuvettes, three 16-mm cuvettes, adapter, mini screwdriver, user manual, certificate of conformity |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco F |
| Pricing | Upon Request |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Amicon Stirred Ultrafiltration Cell |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Water Quality Analyzer |
| Model | Pharo 300 |
| Instrument Type | Benchtop UV-Vis Spectrophotometer for Water Analysis |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon Flash Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A), ±0.5 % (for 0.600 ≤ A ≤ 2.000 A), ±1.0 % (for A > 2.000 A) |
| Cuvette Compatibility | 16 mm round, and 10/20/50 mm square cuvettes with automatic recognition |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan (1 nm increment), Kinetic Assays |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Connectivity | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, US EPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Enclosure Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L × H × W) |
| Weight | 3.7 kg (without battery) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M Air T Air Microbial Sampler |
| Pricing | Available Upon Request |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVP ICON™ |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MAS-100 NT |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Rate Range | 1–2000 L/min |
| Flow Measurement Accuracy | ±2.5% at 100 L/min |
| Total Operating Time | Approx. 5.5 h on full battery charge |
| Storage Temperature | −10°C to +50°C |
| Operating Temperature | 0°C to +40°C |
| Operating Relative Humidity | ≤80% RH (up to +31°C), linearly decreasing to ≤50% RH at +40°C, non-condensing |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | RQflex® 20 |
| Instrument Type | Portable Reflectometric Analyzer for Water, Soil, and Food Matrixes |
| Regulatory Context | Compliant with ISO 15304 (water quality – determination of phosphate), ISO 7890-2 (ammonia), EN ISO 11290-1 (food microbiology – Listeria detection support), USP <643> (total organic carbon correlation), and FDA-recommended methods for residual disinfectant quantification |
| Data Integrity | Audit trail enabled |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | TR320 / TR420 / TR620 |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual Independent Blocks (TR620), Single Block (TR320/TR420) |
| Batch Capacity | 12–24 samples (16 mm digestion tubes) |
| Temperature Range | Ambient to 170 °C (adjustable in 1 °C increments) |
| Temperature Accuracy | ±1.0 °C |
| Inter-Zone Uniformity | ±1.5 °C (vs. setpoint, center vs. periphery) |
| Timer Range | 0–180 min |
| Timer Accuracy | ±1 min |
| Power Supply | 115–230 V~, 50/60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | TR320: 2.85 kg |
| TR420/TR620 | 3.6 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco Cl₂/O₃/pH/ClO₂/CyA |
| Instrument Type | Laboratory & Field-Portable Water Quality Analyzer |
| Optical System | Wavelength-Specific LED Light Source with Interference Filter |
| Measurement Wavelength | 528 nm |
| Measurement Time | 3–4 seconds per test |
| Power Supply | 9-V Alkaline Battery (≈600 measurements per battery) |
| Auto Power-Off | Activated after ≈5 minutes of inactivity |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 30–90 % RH (non-condensing) |
| Compliance | CE-marked per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |