- All
- Favorite
- Popular
- Most rated
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Millivac Compact |
| Pricing | Available Upon Request |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported Pre-Filter Cartridge for Ultra-Pure Water Systems |
| Model | Milli-Q Progard |
| Feed Water Compatibility | Municipal Tap Water |
| Resistivity of Treated Water | ≥5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Recommended Service Life | 6–12 months or up to 30,000 L throughput |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IPAKKIT00 |
| Purity Grade | ASTM Type I / ISO 3696 Grade 1 / CLSI EP25-A2 Compliant |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particles/mL |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Samplicity |
| Pricing | Available Upon Request |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Milli-Q IX7003/05/10/15 |
| Resistivity | >5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <1 ppb |
| Total Organic Carbon (TOC) | ≤30 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Producer |
| Product Type | Imported |
| Model | Milli-Q® SQ2 Series Ultra Pure Water System |
| Pure Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin Level | <0.001 EU/mL |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | 57265 |
| Automation Level | Fully Automatic |
| Channel Count | 24-Channel |
| Extraction Type | Cartridge-Based SPE |
| Construction | Borosilicate Glass Reservoir, PTFE Tubing with Polypropylene Luer Fittings |
| Vacuum Control | Solvent-Resistant Helical Valve & Gauge Assembly |
| Collection Compatibility | 1–10 mL Vials, 10/16 mm Test Tubes, Scintillation Vials (20 mL), Autosampler Vials |
| [Brand | Merck |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Ultra-Pure Water System |
| Model | Elix® Essential |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25 °C (typical 10–15 MΩ·cm @ 25 °C) |
| Conductivity | <0.2 µS/cm @ 25 °C (typical 0.067–0.1 µS/cm @ 25 °C) |
| TOC | <30 ppb (typical) |
| Microbial Count | <10 CFU/mL (with optional UV lamp) |
| Endotoxin | <0.001 EU/mL (with terminal 0.22 µm filter) |
| Particles (>0.1 µm) | <1 particle/mL |
| Flow Rate | 3–15 L/h (selectable) |
| Operating Ambient | 5–35 °C, 20–80% RH |
| Power Supply | 100–230 V AC ±10%, 50–60 Hz |
| Feed Water Pressure | 0.5–6 bar] |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Type | Integrated Laboratory Water Purification System |
| Model | Milli-Q IQ 7003 / IQ 7005 / IQ 7010 / IQ 7015 |
| Feed Water | Municipal tap water |
| Pure Water Grade | ASTM Type II (≥1 MΩ·cm @ 25°C) |
| Ultrapure Water Grade | ASTM Type I (18.2 MΩ·cm @ 25°C) |
| TOC | ≤2 ppb |
| Endotoxin | <0.001 EU/mL |
| Total Microbial Count | <1 CFU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Terminal Filtration | Optional Q-POD® or E-POD® with application-specific cartridges (e.g., Biopak®, Virex®, Orgapak®) |
| UV Source | Mercury-free ech2o® UV lamp (254 nm + 185 nm) |
| RO Recovery | Up to 50% higher vs. conventional systems |
| Data Management | Onboard memory, USB export, QR-coded PDF reports, e-Sure® RFID cartridge tracking |
| Compliance | Designed for USP <1231>, EP 2.2.44, ISO 3696, ASTM D1193, and supports GLP/GMP audit trails per 21 CFR Part 11 requirements |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported |
| Model | Milli-Q® CLX 7000 |
| Pure Water Grade | ASTM Type II (Clinical-Grade) |
| Resistivity | >15 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | 33318-U |
| Temperature Range | Ambient to 150°C |
| Stability at 37°C | ±0.1°C |
| Uniformity within Block at 37°C | ±0.1°C |
| Heat-Up Time to 100°C | 45 min |
| Input Power | 110 W (120 V / 0.9 A or 230 V / 0.5 A) |
| Dimensions | 31.5 × 20.3 × 8.9 cm |
| Weight | 2.6 kg |
| Block Material | Anodized Aluminum |
| Block Compatibility | Interchangeable modular blocks for microtubes, centrifuge tubes, vials, microplates, PCR strips/tubes |
| Thermometer Well | Integrated per block |
| Dual-Range Control | Low (ambient–100°C), High (75–150°C) |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | CD162 & SD162 |
| Plate Material | Glass Ceramic (CD162) / Aluminium-Silicon Alloy (SD162) |
| Plate Dimensions (mm) | 160 × 160 |
| Heated Area (mm) | 120 × 120 (CD162), 160 × 160 (SD162) |
| Heater Power (W) | 500 (CD162), 700 (SD162) |
| Display Resolution | 1 °C |
| Max. Plate Temperature (°C) | 450 (CD162), 300 (SD162) |
| Max. Liquid Temperature (°C, with probe) | 200 |
| Control Accuracy (°C, with probe) | ±0.5 |
| Stirring Speed Range (rpm) | 200–1300 |
| Max. Stirring Capacity (L) | 15 |
| Net Weight (kg) | 3.4 |
| Overall Dimensions (W × D × H, mm) | 190 × 300 × 110 |
| Electrical Supply | 230 V, 50/60 Hz |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Super-Q™ Plus Reagent-Grade Ultra-Pure Water System |
| Pure Water Grade | ASTM Type III |
| Resistivity | 18 MΩ·cm @ 25°C (with embedded temperature-compensated resistivity sensor) |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <20 ppb |
| Microbial Count | <10 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Flow Rate | 10–12 L/min |
| Feed Water Requirements | RO, distilled, or deionized water |
| inlet pressure | 0.03–1 bar |
| Dimensions (W×H×D) | 1150 × 800 × 220 mm |
| Operating Weight (filled) | 63 kg |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported |
| Model | Milli-Q EQ 7000 |
| Price Range | USD 13,500 – 40,500 (est.) |
| Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| TOC | ≤ 5 ppb |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.22 µm) | Non-detectable |
| Microbial Count | < 1 CFU/100 mL |
| Terminal Filtration | 0.22 µm sterile filtration (Millipak® Gold) |
| Compliance | ISO 9001, ISO 14001, FDA 21 CFR Part 11 ready (with optional audit trail module), GLP/GMP-supportive data management |
| Brand | Merck Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported OEM Cartridge |
| Model | Milli-Q Q-GARD Purification Cartridge |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particles/mL |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Model | IPAKGARDH2 |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count & Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported Laboratory Ultra-Pure Water System |
| Model | Super-Q Plus |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count | < 0.01 CFU/mL |
| Endotoxin | < 0.01 EU/mL |
| Particles (> 0.1 µm) | < 0.1 particles/mL |
| Flow Rate | Up to 12 L/min |
| Purification Stages | Pre-filter + Dual Ion Exchange + Organex-Q + Optional Durapore TPE Final Filter |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported Ultra-Pure Water System |
| Model | Milli-Q IQ 7000 |
| Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| TOC | ≤2 ppb (µg/L), typical ≤5 ppb |
| Endotoxins | <0.001 EU/mL |
| Microbial Count | <1 CFU/100 mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Final Filtration | 0.22 µm PES membrane |
| UV Wavelength | 172 nm (Xe-excimer, mercury-free) |
| Compliance | ASTM D1193, ISO 3696, CLSI EP28-A3c, USP <1231>, EP 2.2.44, FDA 21 CFR Part 11 (audit trail enabled) |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RQflex® 20 |
| Price | Upon Request |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Milli-Q® IQ Element |
| Pure Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particulates (>0.1 µm) | ≤1 particle/mL (0.22 µm filter certified) |
| Brand | Supelco |
|---|---|
| Origin | USA |
| Model | 33316 |
| Number of Holes | 8 |
| Block Dimensions (L × W × H) | 95.3 mm × 73.7 mm × 50.8 mm |
| Hole Diameter × Depth | 21 mm × 30 mm |
| Compatible Vessel Capacity | 3–5 mL |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported Laboratory Water Purification System |
| Model | Milli-Q® EQ7008 & Milli-Q® EQ7016 |
| Pure Water Grade | ASTM Type I (Ultrapure) & Type III (Pure) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Microbial Count | < 0.01 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.22 µm) | None detectable |
| Flow Rate | 2 L/min (ultrapure), 8 L/h (EQ7008 RO), 16 L/h (EQ7016 RO) |
| Brand | Milli-Q |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Milli-Q® HX 7000 |
| Pure Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
Show next