- All
- Favorite
- Popular
- Most rated
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA1002 |
| Capacity | 1000 g |
| Readability | 1 mg |
| Repeatability | ±0.8 mg |
| Linearity | ±1.5 mg |
| Calibration | Internal automatic calibration with built-in test weight |
| Display | High-brightness LCD with graphical user interface |
| Interface | USB-A, RS232 |
| Operating Temperature | 10–30 °C |
| Weighing Pan Size | 120 mm diameter stainless steel |
| Dimensions (W×D×H) | 210 × 320 × 325 mm |
| Weight | 4.5 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX303N Precision Balance |
| Maximum Capacity | 32 kg |
| Readability | 1 mg |
| IP Rating | IP54 |
| Compliance | GxP-ready, FDA 21 CFR Part 11 compatible (with optional software), GLP/GMP traceability support |
| Connectivity | RS232, USB, Ethernet (optional), Bluetooth (optional) |
| Power Management | Configurable energy-saving mode |
| Built-in Daily Verification | User-defined test schedules with automated reminders |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E4 XLS+ |
| Instrument Type | Multichannel Pipette |
| Automation Level | Electronic Pipette |
| Channels | 8 |
| Volume Range | 1–300 µL |
| Maximum Capacity | 300 µL |
| Accuracy | ±1.0% at 0.2 µL, ±0.8% at 1.6 µL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX303 Precision Balance |
| Maximum Capacity | 32 kg |
| Readability | 1 mg |
| IP Rating | IP54 |
| Compliance | GxP-ready, FDA 21 CFR Part 11–compatible data handling (with optional software), GLP/GMP traceability support |
| Connectivity | RS232, USB, Ethernet (optional), Bluetooth (optional) |
| Power Management | Configurable energy-saving mode |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IND880 |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Model Range | XPR2U / XPR6 / XPR26 / XPR56 / XS3DU |
| Maximum Capacity | 2.1 g to 52 g |
| Readability | 0.1 µg to 10 µg |
| Repeatability | ≤ ±0.00025 mg |
| Compliance | GxP, USP <41>, <1251>, ISO/IEC 17025, GLP/GMP Audit Trail Ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RX-10 |
| Application Scope | Jacketed laboratory reactors (mL to L scale) |
| Integrated PAT Compatibility | In-situ pH, FTIR, FBRM, PVM, particle size analysis |
| Control Interface | Touchscreen + iC/iControl software suite |
| Regulatory Support | 21 CFR Part 11 compliant audit trail, electronic signature, data integrity features |
| Thermal Control Integration | Compatible with external chillers, heaters, and circulators |
| Data Acquisition | Synchronized timestamped logging of temperature, stirring speed, dosing volume, pH, and PAT sensor streams |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g / 81 g (dual-range) |
| Readability | 0.1 mg / 0.01 mg |
| Repeatability (typ.) | 0.01 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 20 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B, Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Series | XPR Essential |
| Regulatory Compliance | 21 CFR Part 11–compatible (with LabX), USP <41>, ISO/IEC 17025 support |
| User Management | Password-protected, unlimited users, role-based permissions |
| Static Detection | Not integrated |
| Industry Applications | Pharmaceuticals, Chemicals, Food & Beverage, Quality Control Laboratories |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Max Capacity | 220 g / 121 g (dual-range) |
| Readability | 1 mg / 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| Pan Dimensions (W×D) | 78 mm × 73 mm |
| External Dimensions (H×W×D) | 292 mm × 195 mm × 456 mm |
| User Management | Password-protected, unlimited users, role-based permissions |
| Software Compatibility | LabX™ (21 CFR Part 11 compliant) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861e |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Tan δ Range | 0.0001–100 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S4, S9 |
| Portability | Portable |
| Measurement Principle | Polarographic (Clark-type) or Optical (Luminescence-based) — configurable per probe |
| Measurement Range | 0.00–50.0 mg/L (ppm) |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–50 mg/L) |
| Repeatability | ±0.05% of reading |
| Detection Limit | ±2 ppb (O₂ in water) |
| Ingress Protection | IP67 |
| Electrode Compatibility | ISM® (Intelligent Sensor Management) enabled |
| Data Interface | Waterproof USB (IP67-rated) |
| Display | High-contrast, sunlight-readable LCD with StatusLight™ indicator |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | Pipet-One / LTS / XLS |
| Type | Manual Single-Channel Pipettes |
| Compliance | ISO 8655, GLP/GMP-ready |
| Tip Compatibility | LTS (Low-Torque Seal) and Universal Conical |
| Calibration Support | MCP Calibration Workstation (ISO 8655-compliant) |
| Ergonomics | Optimized grip geometry, reduced tip ejection force (<15 N), adjustable volume lock |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1+ Microscopy System, HP DSC1+ Microscopy System |
| Temperature Range | DSC1+: −150 to 700 °C |
| HP DSC1+ | RT to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Pressure Range (HP variant) | Vacuum to 2 MPa |
| Microscope Integration | Compatible with Olympus, Leica, and other OEM optical platforms |
| Compliance | Designed for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | DSC |
| Temperature Range | –95 °C to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor) |
| Simultaneous Sample Measurement | Multiple |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F2 |
| Instrument Type | Portable |
| IP Rating | IP67 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0 °C to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point with 4 preset buffer sets |
| Endpoint Detection | Auto/manual with audible and visual indication |
| Temperature Compensation | Automatic/manual |
| Electrode Interfaces | BNC, Cinch, NTC 30 kΩ |
| Data Storage | 200 measurement records |
| Display | 3.1-inch segmented LCD |
| Power Supply | 4 × AAA batteries (>200 h battery life) |
| Housing Material | ABS |
| Dimensions | 188 × 77 × 33 mm |
| Weight | 0.26 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Integrated Weighing Workflow Solution |
| Models | One Click™ Standard Solution Preparation Package / One Click™ Thermogravimetric Analysis (TGA) Workflow Package |
| Compliance | Designed for GLP/GMP environments |
| Software Platform | LabX 2010 and later |
| Hardware Integration | METTLER TOLEDO XP and XS Series Precision Balances with touchscreen interface |
| Data Integrity | Full audit trail, electronic signatures, 21 CFR Part 11–ready configuration |
| Reporting | Customizable PDF/CSV report generation with sample ID, timestamp, operator, weight values, calculated concentration/residue %, expiry date, and digital signature |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S2, S8 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/Ion) |
| Measurement Range | −2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| Calibration Solution Compatibility | NIST-traceable USA-type buffers (international version) |
| Ingress Protection Rating | IP67 |
| ISM Support | Yes (InLab ISM™ smart electrode recognition) |
| Display | High-contrast sunlight-readable LCD with StatusLight indicator |
| Interface | IP67-rated USB port |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Operating Environment | Lab, field, and process-line applications |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Liquidator 96 |
| Quotation | Upon Request |
| Deck Positions | 3 |
| Pipetting Accuracy | ±5.0% at 5 µL |
| Pipetting Range | 5–200 µL |
| Throughput | 96-well format |
| Dimensions | 381 mm × 406 mm × 33 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (Manufactured in global METTLER TOLEDO facilities) |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.01 mg |
| Minimum Weight (according to USP <41>) | 14 mg |
| Calibration | Fully Automatic Internal Calibration (proFACT Advanced) |
| Environmental Control | Integrated Internal Temperature Control (ITC) |
| Weighing Pan | SmartGrid™ Perforated Grid Pan with Removable Drip Tray |
| Draft Shield | Tool-free Quick-Release, Dishwasher-Safe Glass Draft Shield |
| Compliance | Designed and validated per GWP® (Good Weighing Practice), compliant with ISO/IEC 17025, USP <41>, <1251>, ASTM E898, and supports 21 CFR Part 11 data integrity requirements via LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measured parameters) |
| Sensor Types Supported | 8 (e.g., conductivity/resistivity, pH/ORP, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 × 0/4–20 mA analog outputs |
| Communication | RS232 serial interface |
| Relay Outputs | 4 (optional) |
| Display | Multi-line scrolling LCD with customizable parameter naming |
| Power Supply | Universal 100–240 VAC, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated with sealed rear cover |
| Calibration Support | NIST-traceable verification via optional 1875 Smart Calibrator |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion KF Flex / Pro |
| Sample Capacity | 24 positions |
| Heating Temperature Range | Up to 300 °C (programmable) |
| Gas Flow Control | Digital mass flow controller (air or inert gas) |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation |
| Interface | RS-232, USB, Ethernet (compatible with METTLER TOLEDO titration software tiamo™) |
| Brand | RAININ |
|---|---|
| Origin | Switzerland |
| Model | Pipet-One |
| Type | Manual Single-Channel Pipette |
| Channel Count | 1 |
| Compliance | ISO 8655–2 (Gravimetric Testing), GLP/GMP-Compatible Design |
| Ergonomic Certification | EN ISO 10535–1 (Hand Tools – Ergonomic Requirements) |
| Materials | Chemically Resistant Polypropylene Housing, Stainless Steel Piston, PTFE-Sealed Mechanism |
| Sterilization | Autoclavable (121°C, 20 min, full assembly) |
| Weight Range | 78–112 g (model-dependent) |
| Calibration Interval | Recommended annually per ISO/IEC 17025 guidelines |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 6000TOCi |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis |
| Measurement Range | 0–2000 ppb C |
| Accuracy | ±3% |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.025 ppb C |
| Repeatability | ≤3% |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Drive Precision | 20,000 steps per revolution |
| Compliance | Designed for GLP/GMP environments |
Show next