| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F2 |
| Instrument Type | Portable |
| IP Rating | IP67 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0 °C to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point with 4 preset buffer sets |
| Endpoint Detection | Auto/manual with audible and visual indication |
| Temperature Compensation | Automatic/manual |
| Electrode Interfaces | BNC, Cinch, NTC 30 kΩ |
| Data Storage | 200 measurement records |
| Display | 3.1-inch segmented LCD |
| Power Supply | 4 × AAA batteries (>200 h battery life) |
| Housing Material | ABS |
| Dimensions | 188 × 77 × 33 mm |
| Weight | 0.26 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S2, S8 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/Ion) |
| Measurement Range | −2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| Calibration Solution Compatibility | NIST-traceable USA-type buffers (international version) |
| Ingress Protection Rating | IP67 |
| ISM Support | Yes (InLab ISM™ smart electrode recognition) |
| Display | High-contrast sunlight-readable LCD with StatusLight indicator |
| Interface | IP67-rated USB port |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Operating Environment | Lab, field, and process-line applications |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | SG (pH/mV), FE (Conductivity), FG (Ion Concentration), EL (Dissolved Oxygen) |
| Instrument Type | Portable Electrochemical Analyzer |
| Compliance | ISO/IEC 17025-ready, GLP/GMP traceable data handling, IP67-rated housing |
| Software Integration | LabX direct pH (PC-based data export to Excel, CSV, PDF) |
| Electrode Interface | SmartSensor™ digital recognition & auto-configuration |
| Calibration Modes | Up to 5-point pH, up to 3-point conductivity (Kcell auto-recognition), 2-point DO (zero/saturation), multi-point ion calibration |
| Data Storage | Internal memory for ≥2000 measurement records with timestamp, operator ID, electrode ID, and environmental conditions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | SD50 |
| Measurement Parameters | pH, mV (ORP), ref mV, Ion Concentration (pX, mol/L, mmol/L, mg/L, ppm, %), Temperature |
| pH Range | –2.000 to 20.000 |
| mV Range | –2000.0 to 2000.0 |
| Temperature Range | –30.0 to 130.0 °C |
| Ion Concentration Range | 0 to 999,999 (unit-dependent) |
| pH Resolution | 0.001/0.01/0.1 (selectable) |
| mV Resolution | 0.1 / 1 |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.002 |
| mV Accuracy | ±0.1 (–500.0 to 500.0 mV) or ±0.2 (–2000.0 to 2000.0 mV) |
| Ion Accuracy | ±0.5% of reading |
| pX Accuracy | ±0.002 |
| Temperature Accuracy | ±0.1 °C (0–100 °C) |
| Calibration | Up to 5-point, auto-buffer recognition, 11 built-in buffer sets + 10 customizable sets |
| Endpoint Modes | Auto, Manual, Time Interval |
| Language Support | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Japanese) |
| Data Storage | 2000 GLP-compliant records with timestamp, sample ID, electrode ID, user ID |
| Connectivity | USB (U-disk export), PC software integration |
| Enclosure Rating | IP54 |
| User Management | Dual-level access control |
| Touchscreen | 7-inch full-color capacitive display with glove-mode support |
| Accessories Included | InLab Expert Pro-ISM electrode, EasyMix™ electrode stand, buffer pouches, protective cover, corrosion-resistant interface housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SevenGo Duo |
| IP Rating | IP67 |
| Compliance | GLP-compliant data management |
| Communication | Infrared (IR) interface |
| Channel Configuration | Dual-channel simultaneous measurement |
| Measurement Modes | pH/mV/Ion Concentration, Conductivity/TDS/Salinity/Resistivity, Dissolved Oxygen (DO) |
| Display Language Support | Multilingual (including full Chinese UI) |
| Electrode Technology | ISM® Intelligent Sensor Management |
| Regulatory Alignment | Designed for ISO/IEC 17025 and FDA 21 CFR Part 11–ready environments (audit trail & user authentication enabled via optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured in global METTLER TOLEDO facilities) |
| Model | NineFocus NF2340 Kit |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.002 |
| Conductivity Range | 0.001 μS/cm to 2000 mS/cm |
| Conductivity Resolution | 0.001–0.1 μS/cm (auto-ranging) |
| Conductivity Accuracy | ±0.5% of reading |
| Dissolved Oxygen Range | 0.000–50.000 mg/L |
| DO Resolution | 0.001 mg/L |
| DO Accuracy | ±0.1 mg/L (0–8), ±0.2 mg/L (8–20), ±10% (20–50) |
| ORP/mV Range | –2000 to +2000 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Temperature Range | –30 °C to +130 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.1 °C (0–100 °C) |
| Display | 7" color TFT touchscreen |
| Dimensions (W×D×H) | 111 × 178 × 325 mm |
| Weight | 1.79 kg |
| IP Rating | IP52 |
| Data Storage | 3000 measurement records |
| Connectivity | USB-A, USB-C, mini-DIN (ISM-compatible port), LAN, optional Bluetooth |
| Software Compatibility | LabX™ PC software, GLP-compliant audit trail, 21 CFR Part 11 support |
| Electrode Compatibility | InLab® 731 Pro-DES®, InLab® Expert Pro-DES®, InLab® OptiOx Pro-DES® |
| Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Russian, Turkish, Thai, Simplified & Traditional Chinese |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distributor |
| Model | NineFocus NF2000 |
| Price Range | USD 6,200 – 7,600 (FOB) |
| ORP Range | −2000 to +2000 mV |
| pH Range | −2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 |
| pH Accuracy | ±0.002 |
| mV Resolution | 0.1 / 1 |
| mV Accuracy | ±0.1 |
| Temperature Range | −30 °C to +130 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C (at 0 °C and 100 °C) |
| Display | 7" color TFT touchscreen |
| Dimensions (W × D × H) | 111 × 178 × 325 mm |
| Weight | 1604 g |
| IP Rating | IP52 |
| Data Storage | 3000 measurement records |
| Connectivity | USB-A, USB-C, mini-DIN (ISM-compatible port), LAN, RS-232 (via optional adapter), Bluetooth (optional module) |
| Software Integration | LabX® PC software (full GLP/GMP support), optional barcode reader, stirrer control, and modular parameter expansion |
| Electrode Included | InLab® Expert Pro-ISM pH electrode with digital diagnostics and SmartCal™ traceability |
| Compliance | Fully compliant with ISO/IEC 17025, ASTM D1293, USP <791>, EP 2.2.3, and FDA 21 CFR Part 11 (audit trail, electronic signatures, user roles) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | −2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | Chinese JJG 119 / USP |
| Display | Large backlit LCD |
| Connectivity | RS232 and USB ports |
| Electrode Holder | Removable and stowable |
| Dimensions | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Compliance | Designed for GLP-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | S230 / S400 / S500 / S700 |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% of reading |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Resistivity Range | 0.01 to 100.0 MΩ·cm |
| TDS Range | 0.001 mg/L to 1000 g/L |
| Salinity Range | 0.00 to 80.00 PSU or ppt |
| Display | 7-inch capacitive color touchscreen |
| Connectivity | USB, RS232, Ethernet |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software configuration) |
| Calibration Support | Manual and automated (with Rondolino autosampler) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | InPro (industrial online) / InLab (laboratory & portable) |
| Electrode Types | pH, ORP (Redox), Conductivity |
| Reference Systems | XEROLYT™ solid-state electrolyte, SteadyForce™ pressurized reference |
| Compliance | ATEX, FM, EHEDG, USP <797>, FDA 21 CFR Part 11 (software-enabled systems), ISO/IEC 17025 (calibration traceability) |
| Application Scope | Lab QC, biopharma in-line monitoring, food & beverage CIP/SIP validation, chemical process control, ultrapure water systems |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | China (Domestically Manufactured) |
| Model | NineFocus NF3000 Conductivity Meter Kit |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Resolution | 0.001–0.1 µS/cm (auto-ranging) |
| Conductivity Accuracy | ±0.5% of reading |
| Temperature Range | −30 °C to +130 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C between 0 °C and 100 °C |
| mV Range | −2000 to +2000 mV |
| Display | 7" color TFT touchscreen |
| Dimensions (W × D × H) | 111 × 178 × 325 mm |
| Weight | 1604 g |
| IP Rating | IP52 |
| Data Storage | 3000 measurement records |
| Connectivity | USB-A, USB-C, mini-DIN (ISM-compatible port), LAN, HDMI (ALT/W 4-pin), RS-232 (via adapter) |
| Software Compatibility | LabX® PC software |
| Regulatory Compliance | GLP-compliant |
| Electrode Included | InLab® 731 Pro-DES conductivity sensor with Smart Sensor Recognition (ISM) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | SD20 |
| Measurement Parameters | pH, mV (ORP), ref mV, Temperature |
| pH Range | –2.000 to 20.000 |
| mV Range | –2000.0 to 2000.0 |
| Temperature Range | –30.0 to 130.0 °C |
| Resolution | 0.001/0.01/0.1 pH (adjustable), 0.1/1 mV, 0.1 °C |
| Accuracy | ±0.002 pH |
| Temperature Compensation | Automatic & Manual |
| Calibration Points | Up to 5-point |
| Buffer Sets | 11 preloaded + 10 customizable |
| Endpoint Modes | Auto, Manual, Time Interval |
| Language Support | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Dutch) |
| Data Storage | 2000 GLP-compliant entries with timestamp, sample ID, electrode ID, user ID |
| Connectivity | USB for PC export and printer output |
| IP Rating | IP54 |
| Display | 7-inch full-color capacitive touchscreen |
| User Management | Two-level access control (Operator/Admin) |
| Compliance | Fully GLP-compliant with audit trail-ready data logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Parameter Capability | Multi-parameter |
| pH Accuracy | ±0.002 |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.001 |
| mV Range | –2000 to +2000 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Calibration Standards | NIST-traceable US standard buffer solutions |
| Ingress Protection | IP54 |
| Display | High-contrast color TFT touchscreen |
| Language Support | 12 built-in interface languages |
| Connectivity | USB-A (host & device), RS232, optional Bluetooth® module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28 |
| Instrument Type | Benchtop |
| Parameter Types | pH and mV |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH / 0.1 mV |
| Accuracy | ±0.01 pH |
| Calibration | Manual 1–3 point calibration with standard buffers (e.g., pH 4.01, 7.00, 10.01) |
| Connectivity | RS232 and USB interfaces |
| Display | Large backlit LCD with icon-based status indicators |
| Electrode Holder | Integrated retractable holder |
| Compliance | Designed in accordance with IEC 61010-1 for laboratory electrical safety |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model Range | S400 (pH/mV/ISFET), S470 (pH/mV/ISFET + Conductivity/TDS/Salinity/Resistivity/Conductivity Ash), S500 (pH/mV/Ion Concentration), S700 (Conductivity/TDS/Salinity/Resistivity/Conductivity Ash) |
| Measurement Range | –2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| mV Range | –2000.0 to +2000.0 mV |
| mV Resolution | 0.1 / 1 mV |
| mV Accuracy | ±0.1 mV |
| Conductivity Range | 0.001 µS/cm to 2000 mS/cm |
| Conductivity Accuracy | ±0.5% |
| Temperature Range (ATC/MTC) | –30.0 to 130.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 20,000 data points, 250 analytical result sets |
| Compliance | GLP-compliant data handling, ISO/IEC 17025-ready workflows, supports 21 CFR Part 11 audit trails via LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Measurement Modes | pH, mV, rel. mV, ORP, ion concentration (with appropriate electrode) |
| pH Range | –2.000 to 20.000 |
| Resolution | 0.001 / 0.01 / 0.1 (user-selectable) |
| Accuracy | ±0.002 pH |
| Calibration Options | 1–5 point calibration with automatic buffer recognition |
| Display | 4.3" full-color TFT touchscreen |
| Environmental Rating | IP54 |
| Language Support | 12 languages |
| Connectivity | USB-A (host), USB-B (device), RS232 (optional), Bluetooth (S230 only) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F3 |
| Instrument Type | Portable |
| Measurement Range | Conductivity: 0.00 µS/cm to 200 mS/cm |
| TDS | 0.01 mg/L to 200 g/L |
| Temperature | 0 °C to 100 °C |
| Resolution | Conductivity (auto-ranging), Temperature: 0.1 °C |
| Accuracy | Conductivity: ±0.5 %, Temperature: ±0.5 °C |
| Endpoint Detection | Auto/Manual with audible and visual indication |
| Temperature Compensation | Linear, 0.00–10.00 %/°C |
| Reference Temp | 20 °C or 25 °C |
| Calibration | 1-point, with 3 pre-stored standard solutions |
| Data Storage | 200 measurement records |
| Electrode Interface | LTW 7-pin |
| IP Rating | IP67 |
| Power Supply | 4 × AAA batteries (>200 h operation) |
| Display | 3.1-inch segment LCD |
| Housing Material | ABS |
| Dimensions/Weight | 188 × 77 × 33 mm / 0.26 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model Variants | S400 / S470 / S700 / S600 / S900 |
| Measurement Range | pH: –2.000 to 20.000 |
| mV | –2000 to +2000 |
| Resolution | pH: 0.001 |
| mV | 0.1 |
| Accuracy | ±0.002 pH (model-dependent) |
| Calibration Standards | NIST-traceable US standard buffer solutions |
| Module Configuration | Up to three interchangeable measurement modules (pH, conductivity, ion concentration, redox, dissolved oxygen) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | S40 |
| Measurement Parameters | pH (-2.000 to 19.999), mV/ORP (-1999 to +1999 mV), Conductivity (range dependent on sensor), Ion Concentration (with ion-selective electrodes) |
| pH Accuracy | ±0.002 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 selectable |
| mV Accuracy | ±0.1 mV |
| Temperature Range | -30.0 to 130.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Display | Backlit LCD |
| Data Storage | Up to 1000 GLP-compliant measurement records and 400 GLP-compliant calibration records |
| Compliance | GLP, ISO/IEC 17025-supporting workflows, FDA 21 CFR Part 11-ready with LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F4 |
| Instrument Type | Portable |
| IP Rating | IP67 |
| Measurement Range | 0.1–400 % saturation |
| Temperature | 0–50 °C |
| Pressure Compensation | 375–825 mmHg / 500–1100 mbar / 500–1100 hPa |
| Salinity Compensation | 0.0–50.0 ppt |
| Resolution | 0.1 % |
| Accuracy | ±1% of reading (O₂), ±0.3 °C (temperature) |
| Endpoint Detection | Auto/Manual with audible tone & icon |
| Temperature Compensation | Automatic/Manual |
| Calibration | Two-point (0% and 100% O₂) |
| Data Storage | 200 measurement records |
| Electrode Interface | BNC, Cinch, NTC 30 kΩ |
| Power Supply | 4 × AAA batteries (>200 h operation) |
| Display | 3.1-inch segmented LCD |
| Housing Material | ABS |
| Dimensions/Weight | 188 × 77 × 33 mm / 0.26 kg |