| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861e |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Tan δ Range | 0.0001–100 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1+ Microscopy System, HP DSC1+ Microscopy System |
| Temperature Range | DSC1+: −150 to 700 °C |
| HP DSC1+ | RT to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Pressure Range (HP variant) | Vacuum to 2 MPa |
| Microscope Integration | Compatible with Olympus, Leica, and other OEM optical platforms |
| Compliance | Designed for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | DSC |
| Temperature Range | –95 °C to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor) |
| Simultaneous Sample Measurement | Multiple |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 5+ |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Capacity | Multi-sample (automated) |
| Operating Modes | Power Compensation & Heat Flux (FlexMode™) |
| Sensor Configuration | MultiStar™ sensor with 136 thermocouple pairs |
| Calibration | FlexCal™ automated calibration |
| Atmosphere Control | Integrated gas-purged crucible chamber |
| Modular Architecture | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RC1mx |
| Instrument Type | Reaction Calorimeter |
| Temperature Range | −70 °C to 300 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Accuracy | ±0.5 K |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP/GMP-aligned process safety development and regulatory submission support (e.g., ICH Q5, Q9, Q11 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 / DP90 |
| Temperature Range | RT to 400 °C (DP70), –20 to 400 °C (DP90) |
| Accuracy | ±0.4 °C (–20 to 30 °C), ±0.2 °C (30 to 200 °C), ±0.5 °C (200 °C to max) |
| Heating Rate | 0.1–20 °C/min |
| Compliance | ASTM D3104, D3461, D36, D6089 |
| Data Output | PDF, CSV, video export, LIMS-compatible CSV |
| Sample Carrier | Standardized disposable cups per ASTM/DIN/Ph. Eur. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSC Series (UV-DSC, Optical DSC, Microscope-DSC) |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Professional |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | Dual Pt–Pt/Rh thermocouples |
| Calorimetric Temperature Resolution | 0.0001 °C |
| Calorimetric Accuracy (metal standards) | ±2% |
| Compliance | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | −150 °C to 700 °C (standard), up to 1100 °C (optional furnace) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–250 K/min |
| Heat Flow Sensitivity | 0.04 µW (FRS 5+ sensor), 0.02 µW (HSS 8+ sensor) |
| Sensor Type | MultiSTAR® DSC Sensor (56- or 120-pair Au/Au-Pd thermocouples, star-arranged on ceramic substrate with Al₂O₃ coating) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA 2+ IC/600 / LF/1100 / LN/600 |
| Temperature Range | –80 to 600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Range | –0.1 to 1 N |
| Displacement Resolution | 0.5 nm |
| Frequency Range | 0.01–1 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 / DSC 3+ |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.05 °C |
| Heating/Cooling Rate | 0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 2 |
| Temperature Range | –150 to 700 °C |
| Heating/Cooling Rate | 0.02 to 300 K/min |
| Sensor Type | FRS 6 (56 thermocouples) or HSS8 (120 thermocouples) |
| Autosampler Capacity | 34 positions |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC 2+ |
| Temperature Range | −95 °C to 1,000 °C |
| Heating Rate | 6 K/min to 2,400,000 K/min |
| Cooling Rate | 6 K/min to 240,000 K/min |
| Maximum Heat Flow Signal | 20 mW |
| Heat Flow Noise | < 0.5 µW |
| Sensor Type | UFS1 MEMS-based chip calorimeter with 16 thermocouple pairs (8 per sample/reference side) |
| Measurement Principle | Dynamic power compensation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Applications Handbook – Elastomers |
| Language | English |
| Format | Printed Book + Digital PDF (upon request) |
| Compliance | Aligned with ISO 11357, ISO 11358, ASTM D3418, ASTM E1356, USP <1159> |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Excellence |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Heat Flow Resolution | 0.00003 °C |
| Enthalpy Accuracy (metal standards) | ±1% |
| Compliance | ASTM E1131, ISO 11358, USP <1234>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV-DSC1 |
| Temperature Range | −150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| UV Wavelength Range | 240–400 nm (optional extension to 400–700 nm, visible) |
| UV Irradiance | 4500 mW/cm² (at 365 nm) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1100 |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.25 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-disk SDTA with Pt–Pt/Rh thermocouples |
| Modular Configuration | Optional autosampler, vacuum pump, MS/FTIR coupling, humidity control module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | –150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS 6+ sensor), 0.02 µW (HSS 9+ sensor) |
| Sensor Configuration | 56-pair (FRS 6+) or 120-pair (HSS 9+) Au/Au-Pd thermocouples in star geometry |
| Compliance | ASTM E794, ISO 11357, USP <1163>, FDA 21 CFR Part 11 (with optional software modules) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC1 |
| Temperature Range | 22–500 °C (optional to 700 °C) |
| Heating/Cooling Rate | 0.1–50 °C/min |
| Pressure Range | 0–10 MPa |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Sensor Type | FRS5 (56 thermocouple pairs, star configuration) / HSS8 (120 thermocouple pairs, triple-layer configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55 / MP70 / MP80 / MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Diameter Compatibility | <1.8 mm |
| Sample Capacity | Up to 6 samples simultaneously |
| Compliance | GLP/GMP-ready, ISO/IEC 17025-aligned calibration traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP83/HT |
| Temperature Range | –25 to 375 °C |
| Temperature Accuracy | ±0.2 °C |
| Heating Rate | 0.1–20 °C/min |
| Dropping Point Orifice Diameter | 2.8 mm |
| Softening Point Orifice Diameter | 6.35 mm |
| Compliance | ASTM D3104-82, ASTM D3461-85, ASTM D3954, DIN 51920 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | RT to 1100 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (depending on balance module) |
| Heating/Cooling Rate | 0.02 to 150 K/min |
| Temperature Accuracy | ±1 K |
| Blank Curve Repeatability | < ±10 µg across full temperature range |
| Sensor Type | Single-pan SDTA (Simultaneous Differential Thermal Analysis) |