| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861e |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Tan δ Range | 0.0001–100 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1+ Microscopy System, HP DSC1+ Microscopy System |
| Temperature Range | DSC1+: −150 to 700 °C |
| HP DSC1+ | RT to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Pressure Range (HP variant) | Vacuum to 2 MPa |
| Microscope Integration | Compatible with Olympus, Leica, and other OEM optical platforms |
| Compliance | Designed for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | DSC |
| Temperature Range | –95 °C to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor) |
| Simultaneous Sample Measurement | Multiple |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SC1 / SC30 |
| Sample Capacity | 1 vial (20 mL, 9 mL, or 6 mL) |
| Maximum Sample Viscosity | ≤ 30,000 mPa·s |
| Sample Introduction Method | Positive-pressure pumping |
| Cleaning Protocol | Dual-solvent automated rinse and dry |
| Drying Method | Pneumatic-assisted air-drying |
| Temperature Control | Optional electric heating module (for sample pre-conditioning) |
| Sample Recovery | Optional automatic return to source vial |
| Compliance | Designed for integration with METTLER TOLEDO DE (density), RE (refractometry), and DR (combined density/refractometry) instruments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 5+ |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Capacity | Multi-sample (automated) |
| Operating Modes | Power Compensation & Heat Flux (FlexMode™) |
| Sensor Configuration | MultiStar™ sensor with 136 thermocouple pairs |
| Calibration | FlexCal™ automated calibration |
| Atmosphere Control | Integrated gas-purged crucible chamber |
| Modular Architecture | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RC1mx |
| Instrument Type | Reaction Calorimeter |
| Temperature Range | −70 °C to 300 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Accuracy | ±0.5 K |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP/GMP-aligned process safety development and regulatory submission support (e.g., ICH Q5, Q9, Q11 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Model | X3305 |
| IP Rating | IP65 (standard), IP69K (optional) |
| X-ray Source Power | 20 W |
| System Length | 1.8 m |
| Compliance | GMP, NSF/ANSI 169, EHEDG Guideline Doc. 8.2 |
| Application Scope | Small-to-medium packaged food, pharmaceutical, and consumer goods |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer 400 |
| Instrument Type | In-line Dynamic Imaging System |
| Number of Lenses | 1 |
| Field of View | 1100 µm × 800 µm (±50 µm) |
| Image Resolution | 2200 × 1700 pixels |
| Sample Dispersion Method | In-situ liquid-phase flow-through measurement |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 / DP90 |
| Temperature Range | RT to 400 °C (DP70), –20 to 400 °C (DP90) |
| Accuracy | ±0.4 °C (–20 to 30 °C), ±0.2 °C (30 to 200 °C), ±0.5 °C (200 °C to max) |
| Heating Rate | 0.1–20 °C/min |
| Compliance | ASTM D3104, D3461, D36, D6089 |
| Data Output | PDF, CSV, video export, LIMS-compatible CSV |
| Sample Carrier | Standardized disposable cups per ASTM/DIN/Ph. Eur. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Series | R/T/L/Series |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSC Series (UV-DSC, Optical DSC, Microscope-DSC) |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Professional |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | Dual Pt–Pt/Rh thermocouples |
| Calorimetric Temperature Resolution | 0.0001 °C |
| Calorimetric Accuracy (metal standards) | ±2% |
| Compliance | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyViewer100 |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Number of Lenses | 1 |
| Measurement Range | 1.5 µm – 1 mm |
| Sample Dispersion Method | In-line liquid-phase measurement |
| Image Resolution | 1.5 µm |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | −150 °C to 700 °C (standard), up to 1100 °C (optional furnace) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–250 K/min |
| Heat Flow Sensitivity | 0.04 µW (FRS 5+ sensor), 0.02 µW (HSS 8+ sensor) |
| Sensor Type | MultiSTAR® DSC Sensor (56- or 120-pair Au/Au-Pd thermocouples, star-arranged on ceramic substrate with Al₂O₃ coating) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D30/D40 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Vibrating Tube) |
| Sample Type | Liquids |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00002 g/cm³ |
| Temperature Control Range | 0 to 91.0 °C |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 160, DIN 51757 |
| Data Management | FDA 21 CFR Part 11 compliant software support (via EasyDirect™), GLP/GMP audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA 2+ IC/600 / LF/1100 / LN/600 |
| Temperature Range | –80 to 600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Range | –0.1 to 1 N |
| Displacement Resolution | 0.5 nm |
| Frequency Range | 0.01–1 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 / DSC 3+ |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.05 °C |
| Heating/Cooling Rate | 0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ASN9000 |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 2 |
| Temperature Range | –150 to 700 °C |
| Heating/Cooling Rate | 0.02 to 300 K/min |
| Sensor Type | FRS 6 (56 thermocouples) or HSS8 (120 thermocouples) |
| Autosampler Capacity | 34 positions |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC 2+ |
| Temperature Range | −95 °C to 1,000 °C |
| Heating Rate | 6 K/min to 2,400,000 K/min |
| Cooling Rate | 6 K/min to 240,000 K/min |
| Maximum Heat Flow Signal | 20 mW |
| Heat Flow Noise | < 0.5 µW |
| Sensor Type | UFS1 MEMS-based chip calorimeter with 16 thermocouple pairs (8 per sample/reference side) |
| Measurement Principle | Dynamic power compensation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Applications Handbook – Elastomers |
| Language | English |
| Format | Printed Book + Digital PDF (upon request) |
| Compliance | Aligned with ISO 11357, ISO 11358, ASTM D3418, ASTM E1356, USP <1159> |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Excellence |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Heat Flow Resolution | 0.00003 °C |
| Enthalpy Accuracy (metal standards) | ±1% |
| Compliance | ASTM E1131, ISO 11358, USP <1234>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |