| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | G10S / G20S |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Measurement Range | ±2000 mV / –26.0 to +40.0 pH |
| Meter Accuracy | 0.01% of reading |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DispenSix |
| Measurement Range | −2000 mV to +2000 mV |
| Potentiometric Resolution | 0.1 mV |
| Potentiometric Accuracy | ±0.1 mV |
| Dispensing Precision | ±0.42 µL |
| Dispensing Resolution | 1/120,000 |
| Volume Range | 10 µL – 500 mL |
| Compliance | ISO 8655-3 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion Flex / Pro / Max |
| Measurement Range | ±2000 mV / pH –26.0 to 40.0 |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Compliance | Designed for integration with METTLER TOLEDO Excellence and SevenExcellence™ titrators |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Universal |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Application Scope | General-purpose Titration |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V1 |
| Pricing Range | USD 19,500 – 22,000 (FOB) |
| Titration Principle | Volumetric Coulometric/KF Endpoint Detection via Bipotentiometric Electrode System |
| Dispensing Resolution | 120,000 steps per burette revolution |
| Control Algorithm | Fast Feedback Algorithm (FFA) for dynamic reagent dosing |
| Software Platform | LabX™ PC-based titration software with audit trail and electronic signature support |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 1 µg – 200 mg H₂O |
| Detection Limit | ≤ 0.1 µg H₂O |
| Electrode Recognition | Integrated Smart Chip Interface |
| Cell Design | Modular Two-Part Coulometric Titration Vessel |
| Optional Accessories | Amber Cell, Thermostatted Cell, InMotion KF Oven Integration |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP Data Integrity Ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion™ KF Six |
| Application | Coulometric & Volumetric Karl Fischer Titration |
| Automation | 6-position autosampler with integrated heating oven |
| Sample Handling | Sealed vial-based, one-click sample preparation |
| Gas Flow Control | Digital mass flow controller (air or inert gas) |
| Compliance Support | Designed for GLP/GMP environments with audit trail-ready operation |
| Software Interface | Built-in intuitive touchscreen UI with method-driven workflow |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Price Range | USD 700 – 7,000 (FOB) |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 hours |
| Brand | METTLER TOLEDO |
|---|---|
| Model | DL22 |
| Application Scope | Chloride, Ascorbic Acid, Iodine Value, Peroxide Value, Total Hardness, Free SO₂, Glucose, Kjeldahl Nitrogen, Reducing Sugars, Ca²⁺/Mg²⁺/K⁺, Organic Acids |
| Titration Modes | Endpoint & Equivalence Point Detection |
| Dispensing Modes | Dynamic & Fixed-Volume |
| Burette Resolution | 1/10,000 |
| Potential Resolution | 0.1 mV |
| Data Storage | 100 Sample Results |
| Stirring Options | Magnetic & Propeller |
| Burette Volumes | 1 mL, 5 mL, 10 mL, 20 mL |
| Compliance | GLP/GMP/FDA 21 CFR Part 11–Ready Reporting |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V3 |
| Pricing Range | USD 24,000 – 27,000 (FOB) |
| Titration Principle | Volumetric Karl Fischer (KF) |
| Electrode Type | Dual-platinum generator and indicator electrodes |
| Reagent Delivery Precision | ±0.001 mL per 120,000-step motorized burette |
| Sample Throughput | Up to 30 samples per hour (with autosampler option) |
| Compliance | Fully compatible with FDA 21 CFR Part 11, ISO/IEC 17025, and GLP/GMP data integrity requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 / T7 / T9 |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |