| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1100 |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.25 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-disk SDTA with Pt–Pt/Rh thermocouples |
| Modular Configuration | Optional autosampler, vacuum pump, MS/FTIR coupling, humidity control module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | RT to 1100 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (depending on balance module) |
| Heating/Cooling Rate | 0.02 to 150 K/min |
| Temperature Accuracy | ±1 K |
| Blank Curve Repeatability | < ±10 µg across full temperature range |
| Sensor Type | Single-pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Advanced |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt-Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Standard |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1600 |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.5 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-Pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Standard |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02 to 150 K/min / 0.02 to 250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Yes |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1227>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 LF (Large Furnace) / TGA2 SF (Small Furnace) |
| Temperature Range | Up to 1100 °C (LF), Up to 600 °C (SF) |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.001–100 K/min |
| Furnace Type | Dual-furnace modular architecture |
| Compliance | ASTM E1131, ISO 11358, USP <41>, FDA 21 CFR Part 11 ready |