- All
- Favorite
- Popular
- Most rated
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Drive Precision | 20,000 steps per revolution |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured in METTLER TOLEDO facilities) |
| Instrument Type | Volumetric Karl Fischer Titrator with Integrated Heated Autosampling System |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP-ready |
| Sample Capacity | 26 positions (heated sample carousel) |
| Temperature Control Range | Ambient to 150 °C (adjustable per vial) |
| Titration Resolution | 0.001 mL reagent dispense |
| Reagent Delivery | Dual-piston burette with integrated moisture-tight sealing |
| Software Platform | LabX® with 21 CFR Part 11 compliance, audit trail, electronic signatures |
| Connectivity | Ethernet, USB, RS-232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm to 100% |
| Measurement Resolution | ±2300 mV / 0.1 mV |
| Detection Limit | 0.1 µg H₂O |
| Minimum Water Delivery | 0.2 mg per sample (RSD ≤ 1%) |
| Titration Precision | 120,000 steps |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | FDA 21 CFR Part 11, ISO/IEC 17025, ASTM E203, USP <921>, EP 2.5.12 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET08 |
| Instrument Type | Coulometric & Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | 100 ppm – 100% (w/w) |
| Voltage Input Range | 0–2000 mV |
| Polarization Current Resolution | ±0.1 µA |
| Minimum Detectable Water Content | 100 ppm |
| Dimensions (W×D×H) | 170 × 220 × 350 mm |
| Weight | 1.9 kg (instrument only), +0.8 kg (magnetic stirrer base) |
| Display | 4.3-inch RGB touchscreen (480 × 272 pixels) |
| Power Supply | 24 VDC / 1.25 A |
| Input | 100–240 VAC ±10%, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤80% RH at 31 °C |
| Communication Interfaces | USB-A (high/low speed), USB-B (high/low speed) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Dosing Increment | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured globally per ISO 9001-certified facilities) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Automation | Fully integrated InMotion™ KF Autosampler with programmable heating oven (50–250 °C) |
| Sample Capacity | 26 positions on 25 cm footprint |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP-ready with 21 CFR Part 11 audit trail capability |
| Data Management | Built-in One Click™ workflow automation, METTLER TOLEDO LabX® software compatibility |