BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC1+ Microscopy System, HP DSC1+ Microscopy System
Temperature RangeDSC1+: −150 to 700 °C
HP DSC1+RT to 700 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.02–300 °C/min
Heat Flow Sensitivity0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor)
Pressure Range (HP variant)Vacuum to 2 MPa
Microscope IntegrationCompatible with Olympus, Leica, and other OEM optical platforms
ComplianceDesigned for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
Instrument TypeDSC
Temperature Range–95 °C to 1000 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor)
Simultaneous Sample MeasurementMultiple
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC 5+
Instrument TypeDifferential Scanning Calorimeter (DSC)
Sample CapacityMulti-sample (automated)
Operating ModesPower Compensation & Heat Flux (FlexMode™)
Sensor ConfigurationMultiStar™ sensor with 136 thermocouple pairs
CalibrationFlexCal™ automated calibration
Atmosphere ControlIntegrated gas-purged crucible chamber
Modular ArchitectureYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDSC Series (UV-DSC, Optical DSC, Microscope-DSC)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC3+
Temperature Range−150 °C to 700 °C (standard), up to 1100 °C (optional furnace)
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.02–250 K/min
Heat Flow Sensitivity0.04 µW (FRS 5+ sensor), 0.02 µW (HSS 8+ sensor)
Sensor TypeMultiSTAR® DSC Sensor (56- or 120-pair Au/Au-Pd thermocouples, star-arranged on ceramic substrate with Al₂O₃ coating)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC 3 / DSC 3+
Temperature RangeRT to 1100 °C
Temperature Accuracy±0.05 °C
Heating/Cooling Rate0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC 2
Temperature Range–150 to 700 °C
Heating/Cooling Rate0.02 to 300 K/min
Sensor TypeFRS 6 (56 thermocouples) or HSS8 (120 thermocouples)
Autosampler Capacity34 positions
ComplianceASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelFlash DSC 2+
Temperature Range−95 °C to 1,000 °C
Heating Rate6 K/min to 2,400,000 K/min
Cooling Rate6 K/min to 240,000 K/min
Maximum Heat Flow Signal20 mW
Heat Flow Noise< 0.5 µW
Sensor TypeUFS1 MEMS-based chip calorimeter with 16 thermocouple pairs (8 per sample/reference side)
Measurement PrincipleDynamic power compensation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelUV-DSC1
Temperature Range−150 to 700 °C
Temperature Accuracy±0.1 °C
Heating Rate0.02–300 °C/min
Heat Flow Sensitivity0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor)
UV Wavelength Range240–400 nm (optional extension to 400–700 nm, visible)
UV Irradiance4500 mW/cm² (at 365 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC3+
Temperature Range–150 to 700 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.02–300 K/min (heating), 0.02–50 K/min (cooling)
Heat Flow Sensitivity0.04 µW (FRS 6+ sensor), 0.02 µW (HSS 9+ sensor)
Sensor Configuration56-pair (FRS 6+) or 120-pair (HSS 9+) Au/Au-Pd thermocouples in star geometry
ComplianceASTM E794, ISO 11357, USP <1163>, FDA 21 CFR Part 11 (with optional software modules)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHP DSC1
Temperature Range22–500 °C (optional to 700 °C)
Heating/Cooling Rate0.1–50 °C/min
Pressure Range0–10 MPa
Heat Flow Sensitivity0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor)
Sensor TypeFRS5 (56 thermocouple pairs, star configuration) / HSS8 (120 thermocouple pairs, triple-layer configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHP DSC 2+
Temperature RangeRT to 500 °C / 700 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–50 K/min
Pressure Range0–10 MPa
Gas Flow ControlExternal pressure & mass flow controller supported
Atmosphere CompatibilityInert, oxidizing, reducing, reactive (e.g., N₂, O₂, H₂, CO₂, C₂H₄, CH₃Br), with safety restrictions for combustible/toxic gases
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHS84
Temperature RangeRT to 375 °C (optional cooling to –90 °C)
Heating/Cooling Rate0.1–20 K/min
Light Aperture2 mm
Sensor TypeDSC ceramic sensor with 56 thermocouple pairs
Sample CarriersGlass slides, top cover glass, aluminum/glass/sapphire crucibles
Crucible DimensionsØ6 mm / 40 µL
Display7″ touch-sensitive VGA color screen
Supported LanguagesEnglish, German, French, Spanish, Chinese, Japanese, Korean, Russian
User Shortcuts12 per user
ComplianceASTM F766, EN ISO 3146
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelFP82HT / FP84HT
Temperature Range–60 to 375 °C
Temperature Repeatability±0.2 °C
Optical Field of ViewØ2.5 mm (FP82HT), Ø2.0 mm (FP84HT)
DSC SensorAu–Ni thermopile, 5 thermocouple pairs
Calorimetric Sensitivity13 mV/mW
Sample EnvironmentSealed furnace chamber with inert gas compatibility
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC 3+
Temperature Range-150 to 700 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.02–300 K/min
Sensor OptionsFRS 6+ (56 thermocouples) or HSS 9+ (120 thermocouples)
TAWN Resolution (FRS/HSS)0.12/0.2 °C
TAWN Sensitivity (FRS/HSS)11.9/56 µW/°C
Indium Response Ratio (FRS)>155 mW/°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelTOPEM™ TMDSC
CategoryImported Instrument
Distributor TypeAuthorized General Distributor
PricingAvailable Upon Request