| Brand | Micromeritics |
|---|---|
| Origin | United Kingdom |
| Model | FT4 |
| Instrument Type | Multifunctional Powder Flowability Tester |
| Measurable Powder Parameters | Flow Function, Flow Energy, Aeration Energy, Consolidation Energy, Compressibility, Permeability, Wall Friction Angle |
| Maximum Sample Vessel Capacity | 160 mL |
| Minimum Sample Volume | 1 mL (with optional mini shear cell) / 10 mL (standard) |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Model | Blue Label and Red Label variants |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Reproducibility | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Zeta Potential Range | No effective limit |
| Measurement Time | 3–5 min |
| Molecular Weight Range | 980 Da – 20 MDa |
| Concentration Range | 0.1 mg/mL – 40% w/v |
| Minimum Sample Volume | 3 µL |
| Particle Sizing Method | Non-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®) |
| Zeta Potential Method | M3-PALS (Phase Analysis Light Scattering) with Constant Current Mode |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail |
| Optional Accessories | MPT-3 Auto-Titrator, Polarization/Fluorescence Filter Wheel, Disposable Capillary Cells |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SAS II 5800 |
| Measurement Range | 0.2–75 µm |
| Repeatability | ±1% RSD |
| Porosity Range | 0.2–0.9 |
| Compliance | ASTM B330-12, ASTM C721-14 |
| Display | Integrated Touchscreen Interface |
| Control Software | SAS Control Suite v5.x |
| Dimensions (H×W×L) | 55 × 50 × 38 cm |
| Weight | 28 kg |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Model | Mastersizer 3000+ |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 s |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SediGraph III Plus |
| Measurement Principle | X-ray sedimentation |
| Measurement Range | 0.1–300 µm |
| Repeatability | < 1% RSD |
| Accuracy | < 1% error vs. NIST-traceable standards |
| Analysis Time | 3–15 minutes per sample |
| Sample Volume | 50 mL dispersion |
| Compliance | ISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics) |
| Automation | Unattended analysis of up to 18 samples |
| Optional Integration | MasterTech Auto-sampler for process monitoring and cloud data export |