Add to compare
BrandMicromeritics
OriginUnited Kingdom
ModelFT4
Instrument TypeMultifunctional Powder Flowability Tester
Measurable Powder ParametersFlow Function, Flow Energy, Aeration Energy, Consolidation Energy, Compressibility, Permeability, Wall Friction Angle
Maximum Sample Vessel Capacity160 mL
Minimum Sample Volume1 mL (with optional mini shear cell) / 10 mL (standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
ModelBlue Label and Red Label variants
Particle Size Range0.3 nm – 15 µm
Size Reproducibility±2%
Temperature Control Range10–35 °C
Temperature Stability±0.1 °C
Zeta Potential RangeNo effective limit
Measurement Time3–5 min
Molecular Weight Range980 Da – 20 MDa
Concentration Range0.1 mg/mL – 40% w/v
Minimum Sample Volume3 µL
Particle Sizing MethodNon-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®)
Zeta Potential MethodM3-PALS (Phase Analysis Light Scattering) with Constant Current Mode
Software ComplianceFDA 21 CFR Part 11, GLP/GMP-ready audit trail
Optional AccessoriesMPT-3 Auto-Titrator, Polarization/Fluorescence Filter Wheel, Disposable Capillary Cells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelSAS II 5800
Measurement Range0.2–75 µm
Repeatability±1% RSD
Porosity Range0.2–0.9
ComplianceASTM B330-12, ASTM C721-14
DisplayIntegrated Touchscreen Interface
Control SoftwareSAS Control Suite v5.x
Dimensions (H×W×L)55 × 50 × 38 cm
Weight28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
ModelMastersizer 3000+
Dispersion MethodDry & Wet
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.01–3500 µm
Repeatability<1% RSD
Measurement Time<10 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelSediGraph III Plus
Measurement PrincipleX-ray sedimentation
Measurement Range0.1–300 µm
Repeatability< 1% RSD
Accuracy< 1% error vs. NIST-traceable standards
Analysis Time3–15 minutes per sample
Sample Volume50 mL dispersion
ComplianceISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics)
AutomationUnattended analysis of up to 18 samples
Optional IntegrationMasterTech Auto-sampler for process monitoring and cloud data export